Outlander PHEV Battery Dismantle Manual
*Service Plug Removal Check Sheet
1- ①
Check
#
1- ②
1- ③
2
3- ①
3- ②
*
*Removing the service plug is an extremely important procedure in all work, so copy this page and
use it.
Procedure
Power switch off.
Wait for 2 minutes!
Remove the ground terminal of
the 12V battery.
Remove service lid cover.
Remove service lid nut and
service lid.
Wait for 5 minutes!
Pull up service plug lever.
Remove service plug.
Be sure to carry out preliminary
inspection when detaching each
high voltage part. (ex. high
voltage cable)
Check Sheet
Notes
- Wait for 2 minutes.
- There is a possibility that the power switch is broken.
12v battery is located in the rear cargo area. The rear
hatch release lever will become disabled after battery
power is disconnected. Do not close the rear hatch
until all work is completed.
Wait for 5 minutes to allow voltage to lower. Voltage
of condenser must be sufficiently lowered.
Wear insulated gloves and use insulated tools
when unplugging the service plug.
- Pull out service plug completely as the plug is
energized while removing.
Wear insulated gloves and use insulated tools
when unplugging the service plug or working on
any of the high voltage (orange) cables.