Grounding The Device - Siemens SIMATIC NET Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

IMPORTANT
Install the lightning protector and RP100 as close as possible.
1
2
3
4
5
6
Figure 2.3
2.5

Grounding the Device

The RP100 chassis ground terminal uses a #6-32 screw. It is recommended to
terminate the ground connection with a #6 ring lug and torque it to 8.3 N·m (6
lbf·in).
1
1
2
3
Figure 2.4
RUGGEDCOM RP100
Installation Manual, 01/2021, C79000-G8976-1011-05
1
6
3
3
CPE/PD
Shielded Cable
Ground Connection
Lightning Protector
RP100
Drain Wire (Shielded)
Typical Outdoor Installation
Chassis Ground Connection
#6-32 Screw
#6 Ring Lug
Chassis Ground Connection
2
4
3
Installing the Device
2.5 Grounding the Device