6. How to fix the Front Plate
1 Make sure the Main Switch Knob and Power Control Knob on
Front Plate and it is at "Off" position.
2 Make sure the "D-Cut" position of the Rotary Shaft and VR Shaft
are located as shown.
3 Close the Front Plate of the unit according to the sequence as illustrated.
4 Push in the Main Switch Knob and Power Control Knob until it is fully inserted
<Main Switch Knob and Power Control Knob can not be inserted if
Step 1 and Step 2 is not done accordingly>
5 Fix the screw at the bottom of the Unit.
Note:
1. Do not push the ELB Test Button during fixing the Front Plate.
2. Do not apply extreme force to insert the Main Switch Knob
and Power Control Knob during fixing the Front Plate
because it will damage the switch inside the Unit.
7. Shower Hanger installation.
Install the Shower Hanger so that the Shower Head top is not higher than the Unit top.

3. TEST OPERATION

1. • Before switch "ON" electricity supply check the wiring.
• Switch "ON" the Miniature Circuit Breaker (MCB) and ON/OFF DP (double pole) Switch.
• Set the ELB of the Unit to "On". (Push up the ELB Reset Lever if it is down)
• Push the ELB Test Button.
• It is normal if the ELB turns "Off" (the ELB Reset Lever falls) and push the ELB Reset Lever up.
Refer figure as shown.
• Inspection on the built-in ELB (once a month) to avoid a hazard to users such as damage to
property, serious injury or death.
If the ELB Reset Lever cannot be reset even if you push it up or if it soon slides down
during operation, please do not use the Unit and contact the authorized dealer
immediately to avoid a hazard to users such as damage to property, serious injury or
death. Never fix the ELB Reset Lever forcibly with tape and such.
2. • Turn "ON" the Main Water Valve.
• Turn the Water Volume Knob clockwise.
• Check if water leaks from the Pipe Line.
3. • Turn the Main Switch Knob "On" (ELB lamp will lights).
• Turn the Power Control Knob clockwise and hot water will flow out from the Shower Head.
(Adjust to suitable water temperature).
4. • Refer detail for HOW TO USE and WATER FLOW RATE ADJUSTMENT on page 5.
Shower Hanger
Shower Hanger
Screw
Screw
Wall Plug
WARNING
- 11 -
1
Front Plate
ELB
ELB
Off
High
Off
On
Main Switch Knob
and Power Control Knob
3
4
Front
Back
Plate
Plate
Press
Press
Shower Head
Back Plate
2
"D-Cut"
L
N
Position
5
Screw
ELB
Off
High
Off
ELB T est
On
ELB R eset
Push U
p
DH-3PL 1
OFF
MAX
FILTER
CLEANING
ELB
ELB
Test Button
Off
High
Off
On
ELB Test
ELB Reset
Push Up
DH-3PL1
ELB
FILTER
Reset Lever
CLEANING
Push