4.5.2. Place the laser measuring heads on the rear wheels, ensuring the toe scales are at the rear (fig.13). turn on the lasers and note the
front wheel scale readings (fig.4). these must be equal, if they are not, use the rear wheel track adjusters to equalise them.
4.5.3. check the toe scales at the rear and add both toe scales to find the total toe. If this amount is between 0mm and 2mm then generally
the axle can be said to be correct. If the readings are outside of these limits, adjust both sides equally using the rear track adjusters
until the correct toe is achieved.
fig.12
5.

MainTenanCe

5.1.
After use, always replace all tools and measuring units onto the main unit to minimise damage.
5.2.
If a laser beam becomes difficult to see on the gauge, the batteries in question may need a full charge. If the unit has been switched
off at the mains switch - the charging light will still illuminate even though the batteries are not being charged. re-charge the batteries,
if they are still peforming poorly, they will need replacing.
5.3.
to replace the batteries, remove the battery covers on the laser alignment unit by unscrewing the cover screws, to reveal the battery
compartment. remove the 4 AA ni-cad batteries and fit new batteries. only use ni-cad rechargeable batteries, do not try to charge
normal non-rechargeable batteries. Dispose of batteries (see below). replace the cover and securing screws.
5.4.
Periodically clean all the measuring units and tools with a slightly dampened cloth.
5.5.
the lasers do not need to be calibrated on a regularly basis. If the units are damaged and there is doubt that the laser heads are
still in alignment, contact your sealey dealer to arrange returning the unit for re-calibration.
recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should
be sorted, taken to a recycle centre and disposed of in a manner which is compatible with the environment.
When the product is no longer required, it must be disposed of in an environmentally protective way. contact
your local solid waste authority for recycling information.
1. remove the battery covers on each laser alignment unit by unscrewing the cover screws, to reveal the battery compartment.
2. remove the 4 AA batteries from their holder and dispose of the batteries according to local authority guidelines.
under the Waste Batteries and Accumulators regulations 2009, Jack sealey Ltd are
required to inform potential purchasers of products containing batteries (as defined within these regulations), that they
are registered with Valpak's registered compliance scheme.
Jack sealey Ltd's Batteries Producer registration number (BPrn) is BPrn00705
Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
iMPorTanT: no liability is accepted for incorrect use of this product.
warranTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
inForMaTion: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
environmental Protection.
Battery removal.
sales@sealey.co.uk or phone 01284 757500.