Download Print this page

Toshiba Electromagnetic Flowmeter LF470/LF612 Specification Sheet page 8

Electromagnetic flowmeter

Advertisement

TIC-LF470B
Model
1 2 3 4 5 6 7 8 9 10 11 12 13 14
L F 6 1
2
A
Code explanation:
ISO9001 and ISO14001 are certified.
Misuse of this product can result in damage to property or human injury.
Read related manuals carefully before using this product.
TIC-LF470B
Table 5. Specification Code for converters
Specification Code
Electromagnetic flowmeter converter
Separate (Remote) type
Purpose
Standard
Shape
B
Separate type with case
Converter mounting fitting
A
None
C
Panel, Accessory for wall mounting (BNP material: SUS304)
E
Accessory for pipe installation (BNP material: SUS304)
Digital input/output
1
Digital output points 1 (DO1)
2
Digital output points 2 (DO1+DO2) +Digital input point 1 (DI)
Current output and Communication function
1
Current output + HART communication
2
PROFIBUS communication (Current output is not usable)
Power supply
1
100Vac-240Vac, 50/60Hz
2
24Vdc
3
110Vdc
Instruction manual
E
English
: Standard
Contents
: Option
Specifications are subject to change without notice.
LF612
type
Printed in Japan 2008-5 (TDOC)
© TOSHIBA Corporation 2008
All Rights Reserved.
http://www.toshiba.com/ind/