Wired controller

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Operation
Swing on/off
Press
to switch on or switch off the swing function.
When swing function is turned on, the swing icon will be lit.
When swing function is turned off, the swing icon will be dimmed.
Quiet Function
Press
to switch on or switch off the quiet function.
When quiet function is turned on, the quiet icon will be lit.
When quiet function is turned off, the quiet icon will be dimmed.
ECO function
Dial SW3-8 to ON, the ECO function will be turned on and
controller or turning the power of wired controller on again. The setpoint temperature under mode of
cooling, heating and dry will be limited.
Dial SW3-8 to OFF, the ECO function will turn off and
controller or turning the power of the wired controller on again.
(1) Setting ECO parameter of cooling.
Turn on the wired controller and select cooling mode, adjust the setpoint temperature to 30°C and hold
and
keys for 5s to set ECO parameter which will appear in temperature display area and the
default value is 23. The parameter can be adjusted by
to confirm. If no keys are pressed within 10s after completing the settings, the parameter adjustment
interface will exit automatically and the previous change will be invalid.
ECO parameters of cooling limits the minimum set-point temperature in cooling mode and dry mode.
For example, if ECO parameter of cooling is set to 23, as a result, the set-point temperature range is
23°C to 30°C in cooling mode and dry mode after ECO function is activated.
will display after resetting the wired
will disappear after resetting the wired
or
ranging from 16 to 30. Press