  • Page 1 Edition 04/2022 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RS910L https://www.siemens.com/ruggedcom...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RS910L Communication Ports Technical Specifications Installation Manual Certification 04/2022 C79000-G8976-1030-10...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................vi Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 4 Decommissioning and Disposal ................4 Cabling Recommendations ..................
  • Page 5 Table of Contents 4.3.3 EoVDSL Performance ................... 26 Technical Specifications ...................... 29 Power Supply Specifications ................29 Failsafe Alarm Relay Specifications ..............30 Supported Networking Standards ................ 30 Copper Ethernet Port Specifications ..............30 Fiber Optic Ethernet Port Specifications ............... 31 Serial Port Specifications ..................
  • Page 6: Preface

    SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Accessing Documentation The latest user documentation for RUGGEDCOM RS910L is available online at https:// support.industry.siemens.com.
  • Page 7: Warranty

    Preface Warranty Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 8: Contacting Siemens

    Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RS910L Installation Manual, 04/2022, C79000-G8976-1030-10...
  • Page 10: Introduction

    Introduction The RUGGEDCOM RS910L is a utility-grade serial device server and managed Ethernet switch supporting Ethernet over VDSL (EoVDSL). The RUGGEDCOM RS910L can be configured with two serial ports (RS485/RS422/RS232) and/or two Ethernet ports (copper of fiber). The RUGGEDCOM RS910L can interconnect multiple types of intelligent electronic devices (IEDs) that have different methods of communication.
  • Page 11: Description

    Introduction 1.2 Description Ethernet Over VDSL (EoVDSL) • 2 x Ethernet over VDSL (EoVDSL) ports • Up to 5 km (3.1 mi) LAN segments • Symmetric data rates up to 35 Mbps • Asymmetric data rates up to 40 Mbps • Automatically selects fastest data rate based on distance and quality of cable •...
  • Page 12 Introduction 1.2 Description POWER LED ALARM LED [Optional] Copper (10/100Base-TX) or Fiber Optic (100Base-FX) Ethernet Ports EoVDSL Port Serial Ports RS232 Console Port (Serial) Failsafe Alarm Relay Chassis Ground Connection Power Supply Terminal Block Figure 1.1 RUGGEDCOM RS910L POWER LED Illuminates green during boot up and when power is supplied to the device.
  • Page 13: Required Tools And Materials

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 14: Supported Fiber Optic Cables

    Introduction 1.5.1 Supported Fiber Optic Cables 1.5.1 Supported Fiber Optic Cables The following fiber optic cable types are supported under the stated conditions. Cable Type Wavelength (nm) Modal Bandwidth Distance (m) (MHz·km) 100Base-FX 1000Base-SX 10GBase-SR OM1 (62.5/125) — 1300 2000 — —...
  • Page 15 Introduction 1.5.1 Supported Fiber Optic Cables RUGGEDCOM RS910L Installation Manual, 04/2022, C79000-G8976-1030-10...
  • Page 16: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 17: General Procedure

    Visually inspect each item in the package for any physical damage. Verify all items are included. Note If any item is missing or damaged, contact Siemens for assistance. Installing the Device in Hazardous Locations The RUGGEDCOM RS910L is designed to comply with the safety standards for Class I, Division 2 hazardous locations where concentrations of flammable gases, vapors or liquids may be present, as opposed to normal operating environments.
  • Page 18: Mounting The Device

    Installing the Device 2.4 Mounting the Device Installation and use of the device in a hazardous location should meet the following special conditions for safe use: • The equipment should be installed in an enclosure that is considered to be not accessible in normal operation without the use of a tool providing a degree of protection of not less than IP54.
  • Page 19: Mounting The Device On A Din Rail

    Installing the Device 2.4.1 Mounting the Device on a DIN Rail 2.4.1 Mounting the Device on a DIN Rail The RUGGEDCOM RS910L can be ordered with a DIN rail adapter preinstalled on the back of the chassis. Use the adapter to mount the device to a standard 35 mm (1.4 in) IEC/EN 60715 or TS35 DIN rail.
  • Page 20: Mounting The Device To A Panel

    Installing the Device 2.4.2 Mounting the Device to a Panel Removing the Device To remove the device from a DIN rail, do the following: Insert a flathead screwdriver into the slot of the sliding release and move it down. DIN Rail DIN Rail Adapter Figure 2.2 Removing the Device from a DIN Rail...
  • Page 21: Connecting The Failsafe Alarm Relay

    Installing the Device 2.5 Connecting the Failsafe Alarm Relay Place the device against the panel and align the adapters with the mounting holes. Screw (M3.5 or #6-32) Panel Mount Adapter Figure 2.3 Panel Mounting Secure the adapters to the panel with M3.5 or #6-32 screws. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions.
  • Page 22: Connecting Power

    Installing the Device 2.6 Connecting Power Connect a failsafe device to the terminal block. Normally Closed Common Normally Open Figure 2.4 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RS910L supports power input from a single high AC/DC or low DC power supply. Note •...
  • Page 23: Connecting High Ac/Dc Power

    Installing the Device 2.6.1 Connecting High AC/DC Power 2.6.1 Connecting High AC/DC Power To connect a high AC/DC power supply to the device, do the following: NOTICE Electrical hazard – risk of damage to equipment Do not connect AC power cables to terminals for DC power. Damage to the power supply may occur.
  • Page 24 Installing the Device 2.6.1 Connecting High AC/DC Power Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block. Positive/Live (+/L) Terminal Negative/Neutral (-/N) Terminal Surge Ground Terminal Braided Ground Cable Figure 2.5 Terminal Block Wiring RUGGEDCOM RS910L Installation Manual, 04/2022, C79000-G8976-1030-10...
  • Page 25: Connecting Low Dc Power

    Installing the Device 2.6.2 Connecting Low DC Power ± ± ± ± Positive Terminal Negative Terminal Surge Ground Terminal Braided Ground Cable Figure 2.6 Terminal Block Wiring – Dual DC Power Supply Inputs Connect the negative wire from the power source to the negative/neutral (-/N) terminal on the terminal block.
  • Page 26 Installing the Device 2.6.2 Connecting Low DC Power Connect the positive wire from the power source to the positive terminal on the terminal block. ± ± Positive Terminal Negative Terminal Surge Ground Terminal Braided Ground Cable Figure 2.7 Terminal Block Wiring – Single DC Power Supply Inputs Connect the negative wire from the power source to the negative terminal on the terminal block.
  • Page 27 Installing the Device 2.6.2 Connecting Low DC Power [Optional] If a redundant connection is required, repeat Step 2 Step 3 connect the secondary power inputs. ± ± ± ± Positive Terminal Negative Terminal Surge Ground Terminal Braided Ground Cable Figure 2.8 Terminal Block Wiring – Dual DC Power Supply Inputs Using a braided wire or other appropriate grounding wire, connect the surge ground terminal to the chassis ground connection.
  • Page 28: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RS910L console and Web interfaces on the device. For more detailed instructions, refer to the "RUGGEDCOM ROS Configuration Manual"...
  • Page 29: Configuring The Device

    Device Management 3.2 Configuring the Device The serial console port implements RS232 DCE (Data Communication Equipment) on a DB9 connector. The following is the pin-out for the port:   Name Description Reserved (Do Not Connect) Transmit Data Receive Data Reserved (Do Not Connect) Signal Ground Reserved (Do Not Connect) Reserved (Do Not Connect)
  • Page 30: Communication Ports

    Communication Ports The RUGGEDCOM RS910L can be equipped with various types of communication ports to enhance its abilities and performance. Ports 1 and 2 Ports 3 and 4 Port 9 Figure 4.1 Port Assignment Port Type 1 and 2 Serial Ports 3 and 4 Copper (10/100Base-TX) or Fiber Optic (100Base-FX) Ethernet Ports EoVDSL Port...
  • Page 31 Communication Ports 4.1 Copper Ethernet Ports WARNING Electric shock hazard – risk of serious personal injury and/or equipment interference When shielded cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end. Ground loops can cause excessive noise and interference, but more importantly, create a potential shock hazard that can result in serious injury.
  • Page 32: Fiber Optic Ethernet Ports

    Communication Ports 4.2 Fiber Optic Ethernet Ports Name Description Transmit Data- Reserved (Do Not Connect) Reserved (Do Not Connect) Specifications For specifications on the available copper Ethernet ports, refer to "Copper Ethernet Port Specifications (Page 30)". Fiber Optic Ethernet Ports Fiber optic Ethernet ports are available with either MTRJ (Mechanical Transfer Registered Jack), LC (Lucent Connector), SC (Standard or Subscriber Connector) or ST (Straight Tip) connectors.
  • Page 33: Eovdsl Ports

    EoVDSL line configuration settings are modified on the Master and pushed to the Slave. Data flowing from the Master to the Slave is designated downstream, while data flowing from the Slave to the Master is designated upstream. Siemens supports two types of EoVDSL: • Universal EoVDSL Universal EoVDSL ports are Master/Slave selectable and offer symmetric data rates (upstream and downstream) up to 35 Mbps.
  • Page 34: Eovdsl Wiring

    Communication Ports 4.3.1 EoVDSL Wiring port is set to be a Master or Slave. On devices with Long-Reach EoVDSL ports, the Master LED will be on all the time if the device is set to be the Master, or off if the device is set to be the Slave.
  • Page 35: Configuration And Setup

    Communication Ports 4.3.2 Configuration and Setup • Open leads (also known as bridged taps or drop-lines) along the length of the cable will cause an impedance mismatch and result in VDSL signal degradation. • Make sure the cable impedance is consistent throughout the cable run. Avoid mixing different wiring (e.g.
  • Page 36 Communication Ports 4.3.3 EoVDSL Performance conditions degrade. If Link only is selected, the device will restart the scan process if the line conditions degrade, such that the device is unable to maintain the current link. If Link or SNR is selected, the device will restart the scan process if either the SNR has dropped below a pre-defined acceptable level or when the device is unable to maintain the current link, or whichever comes first.
  • Page 37 Communication Ports 4.3.3 EoVDSL Performance Distance (km) Distance (ft) Downstream (Master Upstream (Slave to Slave) (Mbps) to Master) (Mbps) 4.60 15100 0.54 5.00 16400 0.48 0.18 RUGGEDCOM RS910L Installation Manual, 04/2022, C79000-G8976-1030-10...
  • Page 38: Technical Specifications

    Technical Specifications This section provides important technical specifications related to the device. Power Supply Specifications Note When determining cable lengths, make sure the nominal input voltage for the power supply is provided at the power source. Hazardous Environments Power Input Range Internal Isolation Maximum Power...
  • Page 39: Failsafe Alarm Relay Specifications

    Technical Specifications 5.2 Failsafe Alarm Relay Specifications Failsafe Alarm Relay Specifications Hazardous Environments Maximum Switching Voltage Rated Isolation Switching Current 30 VDC 1500 V for 1 minute 80 VDC 0.3 A 30 VAC Non-Hazardous Environment Maximum Switching Voltage Rated Isolation Switching Current 30 VDC 2 A, 60 W...
  • Page 40: Fiber Optic Ethernet Port Specifications

    3 dBm. To convert from peak to average, subtract 3 dBm. • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. 10Base-FL Fiber Optic...
  • Page 41: Serial Port Specifications

    Technical Specifications 5.6 Serial Port Specifications Tx (dBm) Power Connector Tx λ Cable Distance Mode Sensitivity Saturation Budget Type (nm) Type (μm) Minimum Maximum (km) (dBm) (dBm) (dB) 9/125 1300 9/125 1300 9/125 1300 50/125 1300 -22.5 Typical. Serial Port Specifications The following details the specifications for serial ports that can be ordered with the RUGGEDCOM RS910L.
  • Page 42: Mechanical Specifications

    Technical Specifications 5.8 Mechanical Specifications Mechanical Specifications Weight 1.2 kg (2.7 lbs) Enclosure 20 AWG Galvanized Steel Dimension Drawings Note All dimensions are in millimeters, unless otherwise stated. 65.3 116.59 7.87 Figure 5.1 Overall Dimensions RUGGEDCOM RS910L Installation Manual, 04/2022, C79000-G8976-1030-10...
  • Page 43 Technical Specifications 5.9 Dimension Drawings 128.4 13.64 101.6 11.2 78.74 120.65 Figure 5.2 Panel and DIN Rail Mount Dimensions RUGGEDCOM RS910L Installation Manual, 04/2022, C79000-G8976-1030-10...
  • Page 44: Certification

    Certification The RUGGEDCOM RS910L device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. Approvals This section details the standards to which the RUGGEDCOM RS910L complies. 6.1.1 This device meets the requirements of the following Canadian Standards Association (CSA) standards under certificate 1550963: •...
  • Page 45: Fcc

    Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.4 ISED This device is declared by Siemens Canada Ltd. to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.5...
  • Page 46: Iso

    Quality management systems – Requirements 6.1.7 RoHS This device is declared by Siemens Canada Ltd. to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 47 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels Enclosure Air ± 15 kV Radiated RFI Enclosure 20 V/m 61000-4-3 Ports Burst (Fast Transient) Signal Ports ± 4 kV @ 2.5 kHz 61000-4-4 DC Power ± 4 kV Ports AC Power ±...
  • Page 48 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels Voltage Dips and Interrupts DC Power 30% for 0.1 s   61000-4-29 Ports 60% for 0.1 s 100% for 0.05 s IEC 60255-5 Dielectric Strength Signal Ports 2 kV (Failsafe Relay Output)  ...
  • Page 49 Certification 6.2 EMC and Environmental Type Tests Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068-2-1 Cold Temperature Test Ad -40 °C (-40   °F), 16 Hours IEC 60068-2-2 Dry Heat Test Bd 85 °C (185   °F), 16 Hours IEC 60068-2-30 Humidity (Damp Test Db...
  • Page 50 For more information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens Canada Ltd. Digital Industries Process Automation 300 Applewood Crescent Concord, Ontario, L4K 4E5 Canada © 2022 Siemens Canada Ltd. Subject to change...