Toshiba Lite-Vision plus RBC-AMS51E-EN Installation Manual

Toshiba Lite-Vision plus RBC-AMS51E-EN Installation Manual

Remote controller

Advertisement

Quick Links

+01EN00COV.fm Page 1 Thursday, March 17, 2011 1:11 PM
Lite-Vision plus Remote Controller
Installation Manual
Model name:
RBC-AMS51E-EN
• Read this manual before using the RBC-
AMS51E-EN remote controller.
• Refer to the Installation Manual supplied with the
indoor unit for any installation instructions other
than operations of the remote controller.
Installation Manual
Manuale di installazione
Instrukcja instalacyjna
Εγχειρίδιο εγκατάστασης
Руководство по установке 113
Kurulum kılavuzu
English
1
Italiano
29
Polski
57
Ελληνικά
85
Русский
Türkçe
141

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba Lite-Vision plus RBC-AMS51E-EN

  • Page 1 +01EN00COV.fm Page 1 Thursday, March 17, 2011 1:11 PM Lite-Vision plus Remote Controller Installation Manual Model name: RBC-AMS51E-EN English Installation Manual • Read this manual before using the RBC- AMS51E-EN remote controller. Italiano Manuale di installazione • Refer to the Installation Manual supplied with the indoor unit for any installation instructions other than operations of the remote controller.
  • Page 2: Table Of Contents

    +00EH97062301.book Page 1 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller Contents Precautions for Safety ........... . 2 Accessory Parts .
  • Page 3: Precautions For Safety

    +00EH97062301.book Page 2 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller Precautions for Safety • Read these “Precautions for Safety” carefully before installation. • The precautions described below include important items regarding safety. Observe them without fail. Understand the following details (indications and symbols) before reading the body text, and follow the instructions.
  • Page 4: Accessory Parts

    +00EH97062301.book Page 3 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller Accessory Parts Part name Quantity Remote controller Screws (small) M4 x 20 Wood screws M3.8 x 16 Owner’s Manual Installation Manual (This manual) CD-ROM – 3 –...
  • Page 5: Installation

    +00EH97062301.book Page 4 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller Installation Requirements to install the remote controller ◆ Installation place • Install the remote controller at a height of 1 to 1.5 m from the floor so that the average temperature in the room can be detected.
  • Page 6 +00EH97062301.book Page 5 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller ◆ Remote control wiring and inter-unit wiring between remote controllers Do not allow the wire for the remote controller (communication wire) and the wire for AC220-240 V to come into contact or put them together in one electrical conduit;...
  • Page 7: Install The Remote Controller

    +00EH97062301.book Page 6 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller Install the remote controller NOTE • Wiring for the remote controller should not be bundled or installed in the same conduit with a power cable.; otherwise, malfunction may result.
  • Page 8: Wire The Remote Controller

    +00EH97062301.book Page 7 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller Wire the remote controller Wiring diagram Terminal block for the remote control wiring on the indoor unit Remote control wiring (procured locally) Remote controller * Terminals of A and B Terminal block for have no polarity.
  • Page 9 +00EH97062301.book Page 8 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller Basic wiring diagram NOTE Terminals of A and B have no polarity. To diverge from the indoor unit To diverge from the header remote controller Remote controller Remote controller Remote controller...
  • Page 10: For First Use

    +00EH97062301.book Page 9 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller For first use It takes some time before the remote controller becomes operable when the remote controller is used for the first time. This is not a malfunction. <When the power is turned on for the first time after installation>...
  • Page 11: Part Names And Functions

    +00EH97062301.book Page 10 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller Part Names and Functions Room A 12:00 Cool Mode Fan Speed Temperature sensor ON / OFF] button F1] button Varies its function according to the setting screen. ∧...
  • Page 12: Monitor Screen

    +00EH97062301.book Page 11 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller Monitor screen Check the current usage status. Push [ MONITOR] button. Room A 12:00 The monitor screen appears. Push [ CANCEL] button to return. Cool Mode Fan Speed (1) Displays the set temperature.
  • Page 13: Initial Setting

    +00EH97062301.book Page 12 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller Initial setting Push the [ MENU] button to display the menu screen. Initial setting(1/2) 1.Clock ∧ ∨ 2.Name of room Push the [ ] / [ ] button to select 3.Screen contrast “10.Initial setting”on the menu screen, then...
  • Page 14: Name Of Room

    +00EH97062301.book Page 13 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller To adjust the clock Clock ∧ ∨ Push the [ ] / [ ] button to select Date “1. Clock” on the “Initial setting” screen, Month then push the “...
  • Page 15: Screen Contrast

    +00EH97062301.book Page 14 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller B e d r o o “ Del ” and To delete a character, highlight ABCDE Z & / : · uvwxy push [ MENU] button. F GH I J abcde z–+!?
  • Page 16: Backlight

    +00EH97062301.book Page 15 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller 4. Backlight Turn on or off the back light of the LCD. Initial setting(1/2) ∧ ∨ Push the [ ] / [ ] button to select 1.Clock “4.
  • Page 17: Header/Follower

    +00EH97062301.book Page 16 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller 6. Header/follower Set the remote controller as “Header remote controller” or “Follower remote controller”when the dual remote controller system is used. Carry out the setting operation while the indoor unit is stopped. (Turn off the air conditioning unit before starting the setting operation.) Initial setting(2/2) ∧...
  • Page 18: Language

    +00EH97062301.book Page 17 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller 7. Language Select a language for the screen text. Initial setting(2/2) ∧ ∨ Push the [ ] / [ ] button to select 6.Header/Follower “7. Language” on the “Initial setting” 7.Language screen, then push the “...
  • Page 19: Press & Hold 4Sec

    +00EH97062301.book Page 18 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller 8. Press & hold 4sec. Set the “press and hold” operation for the [ ON / OFF] button. ∧ ∨ Push the [ ] / [ ] button to select “8.
  • Page 20: Field Setting Menu

    +00EH97062301.book Page 19 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller Field setting menu Push the [ MENU] button to display the menu screen. Field setting menu 1.Test mode 2.Register service info. Push and hold the [ MENU] button and 3.Alarm history ∨...
  • Page 21 +00EH97062301.book Page 20 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller Field setting menu ∧ ∨ Push the [ ] / [ ] button to select 1.Test mode “1. Test Mode” on the “Field setting menu 2.Register service info.
  • Page 22: Register Service Info

    +00EH97062301.book Page 21 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller Using the Service monitor with the [ MONITOR] button during the test mode Room A 12:00 Test Cool Mode Fan Speed Push the [ MONITOR] button Monitor function Code Data...
  • Page 23 +00EH97062301.book Page 22 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller Entering information manually Register service info ∧ ∨ Push the [ ] / [ ] button to select 1.Service contact tel No. “2. Register service info” on the field setting 2.Outdoor model name menu screen.
  • Page 24 +00EH97062301.book Page 23 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller Entering the model name and serial number Enter the model name and serial number manually for a Light commercial outdoor unit. Information data is loaded automatically for Light commercial indoor units, VRF indoor units (excluding large capacity air discharge type and duct type), and VRF outdoor units.
  • Page 25 +00EH97062301.book Page 24 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller Outdoor model name ∧ ∨ Push the [ ] / [ ] button to select 1.Manual model name input “1. Manual model name input” on the 2.Model name selection “Outdoor model name”...
  • Page 26: Alarm History

    +00EH97062301.book Page 25 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller Checking the model name or serial number The model name or serial number to be displayed on the Outdoor (Indoor) model name or Outdoor (Indoor) unit serial No.
  • Page 27: Monitor Function

    +00EH97062301.book Page 26 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller 4. Monitor function The sensor temperature or operational status of indoor unit, outdoor unit, or remote controller can be monitored. Monitor function ∧ ∨ Push the [ ] / [ ] button to select “4.
  • Page 28: Dn Setting

    +00EH97062301.book Page 27 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller 5. DN setting Perform the advanced settings for the air conditioner. Carry out the setting operation while the indoor unit is stopped. (Turn off the air conditioning unit before starting the setting operation.) DN setting ∧...
  • Page 29 +00EH97062301.book Page 28 Thursday, March 17, 2011 10:51 AM Installation Manual Lite-Vision plus Remote Controller ....................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
  • Page 30 +01ENCOV4.fm Page 27 Thursday, March 17, 2011 1:12 PM EH97062301...

Table of Contents