4.3.3. Comparing function "comp"

This function enables the operator to compare data stored in two memories selected from among
four memories (the inverter's memory and Remote Keypad memories A, B, and C) as well as to
search for parameters that differ from each other.
The comparing function cannot be used for editing parameters because it is provided only for
searching parameters that differ from each other. Use the "REMOTE KEYPAD MODE" function
described in section 4.2 to edit parameters.
Operating procedure
Key
LED indication
"c0py"
SFT
"comp"
ENT
"in"
SFT
"in"
"in"
ENT
"in a"
<
w
"in c"
SFT
<
w
"a in"
w
<
"a c"
<
w
ENT
"in<a"
"f000"
ENT
"c0mp"
⎯⎯⎯⎯
"_ _ _ _" (4 digits)
"_ _ _ _"
ENT
- If the [ESC] key is pressed, Remote Keypad returns to previous status (except when executing).
< Selecting a desired function >
"c0mp"
Select "comp" (comparing function) with the [SFT] key.
< Entering the selected function >
After selecting "comp" with the [SFT] key, press the [ENT] key
"in"
and "in" (selecting inverter memory) appears in the display
window.
< Selecting a memory >
Each time the [SFT] key is pressed, the display changes as follow
"a"
"b"
"c"
and to "in" again in this order.
< Entering the memory >
After selecting the memory, press the [ENT] key. For example,
<
w
"in a"
select "in", press [ENT] key, and "in a" appears in the display
window.
< Selecting a memory to compare its data with that of the
"in b"
w
<
previously selected memory >
w
<
<
w
Each time the [SFT] key is pressed, the display changes as follow
"in a"
"in a": comparing data between inverter memory and memory A
"in b": comparing data between inverter memory and memory B
"in c": comparing data between inverter memory and memory C
<
w
"a b"
and to "in a" again in this order.
If for example memory A is selected instead of "in" different
w
<
"a in"
indication appears as shown in parentheses.
< Entering the selected memory to compare its data with the
original >
After selecting "in a" (selecting memory A to compare its data
(flashing)
with that of the inverter's memory for example), press the [ENT]
key, and Remote Keypad starts comparing the data of the two
memories with each other.
< Executing data comparison (searching different parameters) >
Remote Keypad compares parameters consecutively while
displaying the parameter title. When Remote Keypad finds two
"f999"
parameters that differ from each other, it discontinues comparing
operation and shows the parameter title flashing in the display
window.
Press the [ENT] again to continue the comparing operation.
< Comparing is complete >
With completion of data comparison, "end" appears in the display
"end"
window followed by "_ _ _ _" which indicates the CRC code
(calculated from the copied data). The CRC code value changes
depending on the condition of the data in the selected memory.
< Ending comparing >
"comp"
Press the [ENT] key and the indication in the display window
returns to "comp".
Key operation and description
"in" (selecting inverter memory)
" a" (selecting memory A)
" b" (selecting memory B)
" c" (selecting memory C)
<
w
<
w
<
w
<
w
<
w
- 12 -