A B
Valid
PIR Re-
Detect
1 ~
 
8
3
Interval
127
Time
Turn Off
0 ~
 
9
Light
4
127
Time
Auto
Report
0 ~
 
10
12
Battery
127
Time
 
11
12
Auto Report
0 ~
Door/Windo
127
w State
Time
0:Enable)
Bit7: Reserve.
Description
In the normal mode, after the PIR
motion detected, setting the re-detect
time. 8 seconds per tick, default tick is
3 (24 seconds).
Setting the suitable value to prevent
received the trigger signal too
frequently. Also can save the battery
energy.
Notice: If this value bigger than the
configuration setting NO. 9. There is a
period after the light turned off and
the PIR not start detecting.
After turn on the lighting, setting the
delay time to turn off the lighting
when the PIR motion is not detected.
8 seconds per tick, default tick is 4 (32
seconds).
0 means never send turn off light
command.
The interval time for auto report the
battery level.
0 means turn off auto report battery.
The default value is 12. The tick time
can setting by the configuration No.20.
The interval time for auto report the
door/window state.
0 means turn off auto report
door/window state.
The default value is 12. The tick time
Name
NO.
Def.
Valid
Name
NO.
Def.
Valid
Auto Report
0 ~
12
12
Illumination
127
Time
Auto Report
0 ~
13
12
Temperatur
127
e Time
Auto Report
0 ~
20
30
Tick
0xFF
Interval
Temperature
0 ~
21
1
Differential
0x7F
Report
11
can setting by the configuration No.20.
Description
A B
Description
A B
The interval time for auto report the
illumination.
0 means turn off auto report
 
illumination.
The default value is 12. The tick time
can setting by the configuration No.20.
The interval time for auto report the
temperature.
0 means turn off auto report
 
temperature.
The default value is 12. The tick time
can setting by the configuration No.20.
The interval time for auto report each
tick. Setting this configuration will
effect configuration No.10, No.11,
 
No.12 and No.13.
Caution: Setting to 0 means turn off
all auto report function.
The temperature differential to report.
0 means turn off this function.
The unit is Fahrenheit.
Enable this function the device will
minutes
detect every
.
 
And when the temperature is over 140
degree Fahrenheit, it will continue
report.
Enable this functionality will cause
some issue please see the detail in the
"Temperature Report" section.