7. Installation and transferring works, and checking

Regarding place for installation
Consult with your dealer for details on installation and transferring the
installation.
Caution:
Never install the Fresh Master where there is a risk of leakage of
flammable gas.
If gas leaks and accumulates around the unit, fire can result.
Never install the Fresh Master at the following place:
where there is much machine oil
near ocean and beach areas where there is much salt
where humidity is high
where there are hot springs nearby
where there is much sulfureted gas
where there is a high-frequency processing machinery (a high-fre-
quency welder, etc.)
where acid solution is frequently used
where special sprays are frequently used
Install the Fresh Master horizontally. Otherwise, water leakage can
result.
Take sufficient measures against noise when installing the Fresh
Master at hospitals or communication-related businesses.
If the Fresh Master is used in any of the above-mentioned environ-
ments, frequent operational failure can be expected. It is advisable
to avoid these types of installation sites.
For further details, consult with your dealer.
Regarding electrical work
Caution:
The electrical work must be undertaken by a person who is
qualified as an electric engineer according to the [technical
standard respecting electrical installation], [internal wiring
rules], and the installation instruction manual with the abso-
lute use of exclusive circuits. The use of other products with
the power source can result in burnt-out beakers and fuses.
Never connect the grounding wire to a gas pipe, water pipe,
arrester, or telephone grounding wire. For details, consult with
your dealer.

8. Specifications

Power
Model
Frequency
supply
name
(Hz)
(V)
GUF-
50RDH3
Single-
GUF-
phase
100RDH3
50
GUF-
220-240
50RD3
GUF-
100RD3
The values given in the table for the noise level reflect the levels measured at a position 1.5 meters immediately below the unit in an anechoic
chamber.
The noise at the air outlets (at a 45° angle, 1.5 meters in front) is about 5-6 dB (A) higher than the values given in the table.
The above values apply during Lossnay ventilation when the fan speed is set to high speed.
*
Capacity in ( ) is heat recovery capacity by Lossnay core.
Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling:
Indoor: 27°C DB/19.5°C WB
Heating:
Indoor: 21°C DB/14.6°C WB
14
Power
Air
Current
con-
volume
(A)
sumption
(W)
m
3
/h
L/S
1.15
235-265
500
139
2.20
480-505
1,000
278
1.15
235-265
500
139
2.20
480-505
1,000
278
Outdoor: 35°C DB/24°C WB
Outdoor: 7°C DB/6°C WB
In some types of installation sites, the installation of an earth
leakage breaker is mandatory. For details, consult with your
dealer.
Regarding transfer of installation
When removing and reinstalling the Fresh Master when you en-
large your home, remodel, or move, consult with your dealer in
advance to ascertain the cost of the professional engineering work
required for transferring the installation.
Caution:
When moving or reinstalling the Fresh Master, consult with your
dealer. Defective installation can result in electric shock, fire, etc.
Regarding noise
In installing work, choose a place that can fully bear the weight of
the Fresh Master and outdoor unit, and where noise and vibration
can be reduced.
Choose a place where cool or warm air and noise from the outdoor
unit's air outlet do not inconvenience the neighbors.
If any alien object is placed near the outdoor unit's air outlet, de-
creased performance and increased noise can result. Avoid plac-
ing any obstacles adjacent to the air outlet.
If the Fresh Master or outdoor unit produces any abnormal sound,
consult with your dealer.
Maintenance and inspection
If the Fresh Master and outdoor unit is used throughout several
seasons, the insides can get dirty, reducing the performance.
Depending upon the conditions of usage, foul odours can be gen-
erated and drainage can deteriorate due to dust and dirt, etc.
Time to change the humidifying element(GUF-50•100RDH3only)
Because impurities and contamination in tap water accumulate on the
humidifying element, the humidifying power of the humidifying element
decreases gradually.
If the humidifying power decreases in the course of use, please con-
sider changing the humidifying element (chargeable to the customer).
Although the time to change the humidifying element varies de-
pending on the conditions such as the operating time and water
quality, it should generally be changed at every five years.
External air load heat
processing capability (kw)
Humidifying
volume
Cooling
Heating
capability
capability
5.29
6.42
(1.66)
(2.25)
10.81
13.00
(3.49)
(4.70)
5.29
6.42
(1.66)
(2.25)
10.81
13.00
(3.49)
(4.70)
Equivalent
Noise
Weight
indoor unit
(dB)
(kg)
capability
2.70
33.5-34.5
57
5.40
38-39
98
33.5-34.5
54
38-39
92
P32
P63
P32
P63