Advertisement

Available languages

Available languages

Quick Links

INSTALLATION MANUAL
GAS COOKTOP
Please read this guide thoroughly before installation.
LSCG366ST
LSCG306ST
MFL62725504_05
LSCG367ST
LSCG307ST
Copyright © 2012 - 2017 LG Electronics Inc. All Rights Reserved.
www.lg.com

Advertisement

Table of Contents
loading

Summary of Contents for LG LSCG366ST/01

  • Page 1 INSTALLATION MANUAL GAS COOKTOP Please read this guide thoroughly before installation. LSCG366ST LSCG367ST LSCG306ST LSCG307ST www.lg.com MFL62725504_05 Copyright © 2012 - 2017 LG Electronics Inc. All Rights Reserved.
  • Page 2: Installation Safety Instructions

    I N S TA L L AT I O N I N S T RU C T I O N S INSTALLATION SAFETY INSTRUCTIONS BEFORE YOU BEGIN Read these instructions completely Note to Installer: Leave these instructions with the appliance after installation is completed. and carefully.
  • Page 3: In The Commonwealth Of Massachusetts

    I N S TA L L AT I O N I N S T RU C T I O N S READ ALL INSTRUCTIONS BEFORE INSTALLATION IN THE COMMONWEALTH OF MASSACHUSETTS • This product must be installed by a licensed •...
  • Page 4: Important Safety Instructions

    I N S TA L L AT I O N I N S T RU C T I O N S INSTALLATION SAFETY INSTRUCTIONS BEFORE YOU BEGIN Remove all tape and packing materials before using the cooktop. Dispose all plastic bags after unpacking the cooktop.
  • Page 5 I N S TA L L AT I O N I N S T RU C T I O N S INSTALLATION SAFETY INSTRUCTIONS (continued) • The ventilating hood must be constructed of sheet • The vertical distance from the plane of the cooking metal not less than 0.0122”...
  • Page 6: Dimensions And Clearances

    I N S TA L L AT I O N I N S T RU C T I O N S DIMENSIONS AND CLEARANCES Provide enough clearances between the cooktop and The cooktop may be placed with 2 3/4” clearance to adjacent combustible surfaces.
  • Page 7 I N S TA L L AT I O N I N S T RU C T I O N S INSTALLING THE COOKTOP UNIT 1. LOCATE ELECTRICAL OUTLET 4. INSTALL THE RETAINER BRACKETS AND GAS SHUT-OFF VALVE Install the retainer brackets to the bottom BENEATH CABINET of the cooktop unit.
  • Page 8: Provide Adequate Gas Supply

    I N S TA L L AT I O N I N S T RU C T I O N S 1. PROVIDE ADEQUATE GAS SUPPLY This cooktop is designed to operate at a pressure of For LP gas, the pressure supplied must be between 5”...
  • Page 9 I N S TA L L AT I O N I N S T RU C T I O N S FLEXIBLE CONNECTOR HOOKUP Pressure regulator Adapter Gas Flow into Range Flex connector (6 ft. max.) Adapter Installer: Inform the consumer of the shut-off valve 1/2”...
  • Page 10: Electrical Connections

    I N S TA L L AT I O N I N S T RU C T I O N S 3. ELECTRICAL CONNECTIONS ELECTRICAL REQUIREMENTS 120 Volt, 60 Hertz, properly grounded dedicated The power cord of this appliance should be equipped circuit protected by a 15 A or 20 A circuit breaker or with a three-prong (grounding) plug which mates with time delay fuse.
  • Page 11: Seal The Openings

    I N S TA L L AT I O N I N S T RU C T I O N S 3. ELECTRICAL CONNECTIONS (continued) The installation of appliances designed for mobile CAUTION home installation should conform with the Manufactured Home Construction and Safety The customer should have the circuit checked by a Standard, Title 24 CFR, Part 3280 (formerly the qualified technician to make sure the receptacle is...
  • Page 12: Assemble The Surface Burners

    I N S TA L L AT I O N I N S T RU C T I O N S 5. ASSEMBLE THE SURFACE BURNERS CAUTION Make sure the hole in the burner head is positioned over the electrode. DO NOT operate the burners without all parts in place.
  • Page 13: Adjust The Surface Burner Low Flame (Simmer) Setting

    I N S TA L L AT I O N I N S T RU C T I O N S 7. ADJUST THE SURFACE BURNER LOW FLAME (SIMMER) SETTING For all surface burners except for the center 7. Position center burner head, center burner cap, center grate, and center knob.
  • Page 14: Converting To Lp Gas

    I N S TA L L AT I O N I N S T RU C T I O N S WHEN ALL HOOKUPS ARE COMPLETE Make sure all controls are left in the off position. Make sure the flow of combustion and ventilation air to the cooktop is unobstructed.
  • Page 15: Manual De Instalación

    MANUAL DE INSTALACIÓN COCINA DE GAS Por favor lea esta guía completamente antes de la instalación. LSCG366ST LSCG367ST LSCG306ST LSCG307ST www.lg.com P/No.: MFL62725504 Copyright © 2012 - 2017 LG Electronics Inc. Todos los Derechos Reservados.
  • Page 16 I N S T RU C C I O N E S D E I N S TA L AC I Ó N INSTRUCCIONES DE SEGURIDAD DURANTE LA INSTALACIÓN ANTES DE COMENZAR...
  • Page 17: Para Su Seguridad

    I N S T RU C C I O N E S D E I N S TA L AC I Ó N LEA TODAS LAS INSTRUCCIONES ANTES DE REALIZAR LA INSTALACIÓN EN EL ESTADO DE MASSACHUSETTS • Este producto debe ser instalado por un fontanero •...
  • Page 18: Instrucciones De Instalación

    I N S T RU C C I O N E S D E I N S TA L AC I Ó N INSTRUCCIONES DE SEGURIDAD DURANTE LA INSTALACIÓN ANTES DE COMENZAR Retire todas las cintas y materiales de embalaje antes de usar el horno. Deseche todas las bolsas de plástico tras desembalar la cocina.
  • Page 19 I N S T RU C C I O N E S D E I N S TA L AC I Ó N INSTRUCCIONES DE SEGURIDAD DURANTE LA INSTALACIÓN (continuación) • El extractor de ventilación debe estar compuesto • La distancia vertical desde el plano de la superficie por láminas metálicas con un grosor no inferior a de cocción hasta la base de los armarios 0.0122”.
  • Page 20: Dimensiones Y Espacios Libres

    I N S T RU C C I O N E S D E I N S TA L AC I Ó N DIMENSIONES Y ESPACIOS LIBRES Permita los espacios libres adecuados entre la El emplazamiento de las tomas eléctricas y las cocina y las superficies combustibles adyacentes.
  • Page 21 I N S T RU C C I O N E S D E I N S TA L AC I Ó N INSTALACIÓN DE LA UNIDAD DE LA COCINA 1. LOCALICE LA TOMA ELÉCTRICA Y 4. INSTALE LOS SOPORTES DE LA VÁLVULA DE CORTE DE GAS RETENCIÓN POR DEBAJO DEL ARMARIO.
  • Page 22 I N S T RU C C I O N E S D E I N S TA L AC I Ó N 1. PROPORCIONE EL SUMINISTRO DE GAS ADECUADO Su cocina está diseñada para funcionar a una Para gas LP, la presión de suministro debe estar presión de 5”...
  • Page 23 I N S T RU C C I O N E S D E I N S TA L AC I Ó N CONEXIÓN DEL CONECTOR FLEXIBLE Regulador de presión Adaptador Flujo de gas al horno Conector flexible (máx. 6 pies) Instalador: comunique al Adaptador cliente el emplazamiento...
  • Page 24: Conexiones Eléctricas

    I N S T RU C C I O N E S D E I N S TA L AC I Ó N 3. CONEXIONES ELÉCTRICAS REQUISITOS ELÉCTRICOS 120 voltios, 60 hercios, conexión a tierra adecuada, El cable de alimentación de este electrodoméstico circuito propio protegido mediante disyuntor de 15 ó...
  • Page 25 I N S T RU C C I O N E S D E I N S TA L AC I Ó N 3. CONEXIONES ELÉCTRICAS (continuación) La instalación de electrodomésticos diseñados para PRECAUCIÓN instalaciones en viviendas móviles debe cumplir con el Manufactured Home Construction and Safety El cliente debe solicitar a un electricista que revise Standard, título 24 CFR, sección 3280...
  • Page 26 I N S T RU C C I O N E S D E I N S TA L AC I Ó N 5. MONTE LOS FOGONES PRECAUCIÓN Asegúrese de colocar el hueco de la cabeza del quemador sobre el electrodo. No use los quemadores sin haber montado todas sus piezas en su sitio.
  • Page 27 I N S T RU C C I O N E S D E I N S TA L AC I Ó N 7. REDUCIR LA LLAMA DEL QUEMADOR A LA POSICIÓN BAJA (COCER A FUEGO LENTO). Para todos los quemadores a excepción del 7.
  • Page 28 I N S T RU C C I O N E S D E I N S TA L AC I Ó N AL TERMINAR TODAS LAS CONEXIONES Asegúrese de dejar todos los controles en la posición de apagado. Asegúrese de que el flujo de combustión y el aire de ventilación al horno no estén obstruidos.
  • Page 29 M E M O...
  • Page 30 M E M O...
  • Page 31 M E M O...
  • Page 32 Printed in Korea...