Wired controller

Advertisement

Operation
Energy saving
(1) Press MENU key, you will enter function circulation, use 
or
 key to switch between different functions. Switch to
function, then press MENU key again, energy saving function
will be turned on. If the function is turned on,
icon will be
displayed in the main interface.
When the energy saving function is set, press MENU key to
enter function circulation and choose
, then press MENU
key to exit energy saving function.
(2) If the energy saving function is turned on, the adjustment 
of the setting temperature of the cooling/dry/heating mode will
be limited. The energy saving default parameters are 23°C (the 
lowest temperature limit of cooling and dry mode) and 26°C (the 
highest temperature limit of heating mode).
(3) The energy saving parameters can be changed. 
① In cooling mode, set temperature to 30°C, long press FAN 
key for 5 seconds to enter energy saving parameter of cooling/
dry mode setting, the parameter will be displayed in the top-left
corner. You can use
or
key to adjust parameter, and the
parameter adjustment range is from 16 to 30. After adjustment,
you need to press MENU key to confirm changes.
16