1. ADJUSTMENT PROCEDURES

TO AVOID POSSIBLE EXPOSURE TO MICROWAVE
E N E R G Y L E A K A G E , T H E F O L L O W I N G
ADJUSTMENT OF THE INTERLOCK SWITCHES
SHOULD BE MADE ONLY BY AUTHORIZED
S E R V I C E
P E R S O N N E L .
The SANYO service center should have the designated
detector to measure the microwave energy leakage
after the repair or adjustment.
NOTE
: Detector to be used at the service center is
NARDA 8100, 8200 or the equivalent.
PRIMARY INTERLOCK SWITCH, INTERLOCK
MONITOR SWITCH AND DOOR SENSING SWITCH
ADJUSTMENT
(Figure 1)
(1) Loosen 2 screws securing the Lever Stopper.
(2) Adjust the Lever Stopper position so that it is pushed
forward and pull backward until there is about zero
gap between the Latch Lever and the switch body on
the Primary Interlock Switch and at the same time
there is about zero gap between the Door Latch and
the switch body on the Door Sensing Switch when
the Door Latch is securely locked.
(3) Tighten the Lever Stopper screws securely.
(4) Make sure the Interlock Monitor Switch closes after
the Primary Interlock Switch opens when the door
is opened very slowly, according to "CHECKOUT
PROCEDURE FOR SWITCHES" o n p a g e 6 .
(5) Make sure the Interlock Monitor Switch opens before
the Primary Interlock Switch closes when the door is
closed very slowly, according to "CHECKOUT
PROCEDURE FOR SWITCHES" o n p a g e 6 .
(6) Make sure the microwave energy leakage should be
no greater than 4mW/cm
uncertainty when measured with a detector.
(All service adjustments must be made for
minimum microwave energy leakage readings.)

- TABLE OF CONTENTS -

to allow for measurement
2
Circuit Diagram .............................................
Disassembly Instructions ................................
Exploded View and Parts List .......................... 11 ~ 14
NOTE
: If the Interlock Monitor Circuit operates and
at the same time the fuse blows with the
d o o r o p e n e d , b e s u r e t o r e p l a c e t h e
Door Sensing Switch and the electric
circuit related on the Door Sensing Switch,
which act as Secondary Interlock Switch.
Screws
Figure 1
- 1 -
3
4 ~ 7
8 ~ 10
Door
Latch
Lever Stopper
Door
Sensing
Switch
Interlock
Monitor
Switch
Latch
Primary
Interlock
Lever
Switch

Advertisement

loading

This manual is also suitable for:

Em-f1010mbEmf1010mEm-f1010mw437 373 73