Frigidaire FGID2468UD Use & Care Manual page 15

Table of Contents

Advertisement

Care of Drain Air Gap
If a drain air gap was installed for your built-in
dishwasher, check to make sure it is clean so
the dishwasher will drain properly. A drain air
gap is usually mounted on countertop and can
be inspected by removing the cover. This is
not part of your dishwasher and is not covered
by warranty.
CAUTION
Property Damage Hazard
Freezing temperatures may cause water
lines to rupture. Be sure all supply lines to
and circulating lines within dishwasher are
protected.
Failure to do so could result in property
damage.
NOTE
See Installation Instructions for more details
on disconnecting and restoring service to
your dishwasher.
CARE AND CLEANING
Winterizing
A dishwasher left in an unheated place should
be protected from freezing. Have a qualified
person do the following:
To Disconnect Service:
1.
Turn off electrical power to the
dishwasher at the supply source by
removing fuses or tripping circuit breaker.
2.
Shut off water supply
3.
Place a pan under the inlet valve.
Disconnect water line from inlet valve and
drain into pan.
4.
Disconnect drain line from pump and
drain water into pan.
To Restore Service:
1.
Direct water line discharge into a pan
and open the valve to flush the line.
2.
Reconnect the water, drain, and
electrical power supply.
3.
Turn on water and electrical power
supply.
4.
Fill both detergent cups and run
dishwasher through a POWER PLUS
cycle.
5.
Check connections to make sure they do
not leak.