INSTALLATION INSTRUCTIONS 30" (76.2 CM)
FREESTANDING ELECTRIC RANGE
INSTRUCTIONS D'INSTALLATION POUR
CUISINIÈRE ÉLECTRIQUE AUTOPORTANTE
AVEC FOURS DOUBLES DE 30" (76,2 CM)
RANGE SAFETY .............................................................................1
INSTALLATION REQUIREMENTS .................................................2
Tools and Parts .............................................................................2
Location Requirements ................................................................2
Electrical Requirements - U.S.A. Only .........................................4
Electrical Requirements - Canada Only .......................................5
INSTALLATION INSTRUCTIONS ...................................................5
Unpack Range..............................................................................5
Adjust Leveling Legs ....................................................................5
Install Anti-Tip Bracket .................................................................6
Electrical Connection - U.S.A. Only .............................................7
Level Range ................................................................................12
Complete Installation .................................................................13
Moving the Range ......................................................................13
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
IMPORTANT:
Save for local electrical inspector's use.
IMPORTANT :
À conserver pour consultation par l'inspecteur local des installations électriques.
W10694065B
WITH DOUBLE OVENS
Table of Contents/Table des matières

RANGE SAFETY

Your safety and the safety of others are very important.
SÉCURITÉ DE LA CUISINIÈRE ...................................................14
EXIGENCES D'INSTALLATION ...................................................15
Outils et pièces ...........................................................................15
Exigences d'emplacement .........................................................15
Spécifications électriques ..........................................................17
INSTRUCTIONS D'INSTALLATION .............................................17
Déballage de la cuisinière ..........................................................17
Réglage des pieds de nivellement .............................................17
Installation de la bride antibasculement ....................................18
Vérifier que la bride antibasculement
est bien installée et engagée .....................................................18
Réglage de l'aplomb de la cuisinière .........................................19
Achever l'installation ..................................................................20
Déplacement de la cuisinière .....................................................20
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.

Advertisement

Table of Contents
loading

Summary of Contents for KitchenAid KFED500EWH03

  • Page 1: Table Of Contents

    INSTALLATION INSTRUCTIONS 30" (76.2 CM) FREESTANDING ELECTRIC RANGE WITH DOUBLE OVENS INSTRUCTIONS D’INSTALLATION POUR CUISINIÈRE ÉLECTRIQUE AUTOPORTANTE AVEC FOURS DOUBLES DE 30" (76,2 CM) Table of Contents/Table des matières RANGE SAFETY ................1 SÉCURITÉ DE LA CUISINIÈRE ...........14 INSTALLATION REQUIREMENTS ..........2 EXIGENCES D’INSTALLATION ...........15 Tools and Parts ................2 Outils et pièces ................15...
  • Page 2: Installation Requirements

    WARNING Tip Over Hazard A child or adult can tip the range and be killed. Install anti-tip bracket to floor or wall per installation instructions. Slide range back so rear range foot is engaged in the slot of the anti-tip bracket. Re-engage anti-tip bracket if range is moved.
  • Page 3 Product Dimensions Cabinet Dimensions Cabinet opening dimensions shown are for 25" (63.5 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height. IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
  • Page 4: Electrical Requirements - U.s.a. Only

    Electrical Requirements - U.S.A. Only If codes permit and a separate ground wire is used, it is If connecting to a 4-wire system: recommended that a qualified electrical installer determine that This range is manufactured with the ground connected to the the ground path and wire gauge are in accordance with local neutral by a link.
  • Page 5: Electrical Requirements - Canada Only

    Electrical Requirements - Canada Only WARNING Range Rating* Specified Rating of Power Supply Cord Kit and Circuit Protection 120/240 Volts 120/208 Volts Amps 8.8 - 16.5 KW 7.8 - 12.5 KW 40 or 50** 16.6 - 22.5 KW 12.6 - 18.5 KW * The NEC calculated load is less than the total connected load Electrical Shock Hazard listed on the model/serial/rating plate.
  • Page 6: Install Anti-Tip Bracket

    Install Anti-Tip Bracket 3. Determine and mark edge of range in the cutout space. The WARNING mounting bracket can be installed on either the left side or right side of the cutout. Position mounting bracket in cutout so that right (or left) edge of the bracket is "...
  • Page 7: Electrical Connection - U.s.a. Only

    Electrical Connection - U.S.A. Only Power Supply Cord Direct Wire WARNING WARNING Electrical Shock Hazard Electrical Shock Hazard Disconnect power before servicing. Disconnect power before servicing. Use 8 gauge copper or 6 gauge aluminum wire. Use a new 40 amp power supply cord. Electrically ground range.
  • Page 8 Style 2: Direct wire strain relief Feed the flexible conduit through the strain relief, ■ allowing enough slack to easily attach wiring to the Use Phillips screwdriver to remove screws and slide cord/ ■ terminal block. conduit plate down and out. Tighten strain relief screw against the flexible conduit.
  • Page 9 5. Use " nut driver to connect the neutral (white) wire to the 4-wire connection: Power Supply Cord center terminal block post with one of the 10-32 hex nuts. Use this method for: New branch-circuit installations (1996 NEC) ■ Mobile homes ■...
  • Page 10 2. Use " nut driver to connect the neutral (white) wire to the 4-wire Connection: Direct Wire center terminal block post with one of the 10-32 hex nuts. Use this method for: New branch-circuit installations (1996 NEC) ■ Mobile homes ■...
  • Page 11 4. Attach terminal lugs to line 1 (black), neutral (white), and line 3-wire connection: Direct Wire 2 (red) wires. Loosen (do not remove) the setscrew on the front of the terminal lug and insert exposed wire end through Use this method only if local codes permit connecting ground bottom of terminal lugs.
  • Page 12: Verify Anti-Tip Bracket Is Installed And Engaged

    Bare Wire Torque Specifications 2. Slowly attempt to tilt the range forward. Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m) If you encounter immediate resistance, the range foot is engaged in the anti-tip bracket. Wire Awg Torque 3.
  • Page 13: Complete Installation

    If removing the range is necessary for cleaning or maintenance: Complete Installation For power supply cord-connected ranges: 1. Slide range forward. 1. Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was 2.