Terminal Descriptions; Keypad Maximum Wire Run - GE NETWORX Series Installation And Start-Up Manual

Hide thumbs Also See for NETWORX Series:
Table of Contents

Advertisement

XIV.

TERMINAL DESCRIPTIONS

TERMINAL
R1
House Telephone Ring (Grey).
R
Telephone Ring (Red).
T
Telephone Tip (Green).
T1
House Telephone Tip (Brown).
EARTH
Earth Ground. Connect to a cold water pipe or a 6 to 10 foot driven rod.
AC
AC input. Connect to a 16.5V, 40VA or 50 VA Class ll U.L. approved transformer.
If used as a siren output (default), the speaker rating should be 15 watt at 8 or 16 ohm, or 30/40
watt at 4, 8, or 16 ohms. If voltage output is selected in location 37, this output becomes voltage
BELL + &
output, 12VDC, 1 Amp maximum load. NOTE: A 3.3K Ω resistor may be required across the
BELL -
bell terminals when a 12 VDC siren is used. If no resistor is used, you may experience
voltage leakage into the siren, which will cause these devices to output a small signal.
Connect to the data terminal on the keypads and the expanders. Maximum number of devices
KP DATA
(keypads + expanders) is 32. See AMaximum Wire Run@ chart below.
KP COM
Connect to the Common terminal on the keypads and the expanders.
Connect to the POS terminal on the keypads and the expanders. Individually, this terminal is
KP POS
limited to 1 Amp. Combined, this terminal and AUX PWR + are limited to 2 amps total current.
Smoke detector power 12VDC, 1.5 amps maximum (For those jurisdictions which allow the Priority
SMOKE+
zone to be used with smoke detectors.)
COM
Connect negative wire of powered devices such as motion detectors and smoke detectors.
Connect positive wire of all powered devices except smoke detectors and keypads. Individually,
AUX PWR+
this terminal is limited to 1 Amp. Combined, this terminal and KP POS are limited to 2 amps total
current.
Connect to one side of zone 8 loop. Connect the other side to com terminal. Open or short causes
alarm. Zone 8 may be used for a two-wire smoke detector using a 680 Ω E.O.L. resistor.
ZONE 8
Connect one side to AUX PWR+ ONLY if using 2-wire smoke. Refer to wiring diagram.
Program location 37, segment 6, option 1.
COM
Common (-) terminal for zones 7 & 8. (See the wiring diagram for examples.)
Connect to one side of zone 7 loop. Connect the other side to COM terminal. Open or short causes
ZONE 7
alarm.
ZONE 6 -
Connect as described for zones 7 & 8. Only zone 8 can be a two-wire zone. (See the wiring
ZONE 1
diagram for examples.)
RELAY
C
Closed dry contact rated 1 Amp at 30 Volts.
2
NO
Normally open dry contact rated 1 Amp at 30 Volts.
COM
Common used to ground any devices connected to relays.
RELAY
NC
Normally closed dry contact rated 1 Amp at 30 Volts
1
C
Closed dry contact rated 1 Amp at 30 Volts
(See terminal
AUX 1-
drawing)
AUX 4

KEYPAD MAXIMUM WIRE RUN

(Note: These numbers are for one keypad at the end of the wire. When connecting more than one keypad to the end
Length in feet
250
500
1000
1500
2500
NX-8E CONTROL
Connect negative lead of low current device [relay, LED (install 1kΩ resistor in series
with LED), etc.]. Connect positive lead of device to AUX PWR +. Current is limited to
50mA when output is negative, and 250FA when output is positive. Part number #8920
is 4-wire cable.
of the wire, a higher gauge wire will be required.)
WHEN CONNECTED TO NX-8E
Wire Gauge
24
20
18
16
14
DESCRIPTION
NOTE: These terminals can be
set for 12VDC. Install J12 for
AUX1 and J13 for AUX2 (See
WHEN CONNECTED TO NX320-E
terminal drawing.)
Wire Gauge
22
18
16
14
12
67