Download Print this page

Kenmore 625.343800 Owner's Manual page 7

Undersink water filter housing
Hide thumbs Also See for 625.343800:

Advertisement

C.
THREADED PIPE AND FITTINGS, FIG. 3
MATERIALS AND TOOLS NEEDED: For threaded pipe
installation, you will need pipe wrenches, Teflon tape
or pipe joint compound, a union fitting and pipe nip
ples. You may also need a pipe threading tool. Con
nect the filter housing as typically shown in FIG. 3,
page 5. Observe the following:
H Use Teflon tape or pipe joint compound on all exter
nal threads.
D.
INSTALLATION WITH FAUCET KIT, FIG. 4
Follow instructions included with the Faucet kit.
1. Close the cold water side shutoff valve. (Usually,
there already is a shutoff under the sink. If not, close
the main water shutoff valve near the water meter or
pressure tank.)
2. Cut and remove a section of the cold water pipe.
3. If plumbing with flexible tubing, hang or support
the filter housing in some manner. Using the mounting
bracket (included with Deluxe model) as shown in
TURN TO PAGE 8 AND FOLLOW ALL STEPS UNDER ``FILTER CARTRIDGE REPLACEMENT''.
All manuals and user guides at all-guides.com
INSTALLATION STEPS (cont.)
FILTER CARTRIDGE INSTALLATION
7
H Do not turn pipe or fittings to tightly into the filter
head or you may break it.
H It is important to have some movement in the sink
cold water pipe. This will allow you to tighten the
union fitting, without damaging the filter head, if pipe
lengths are not exact.
H Before turning on the water supply, remove the
sump from the filter head and install the filter cartridge
(see below).
FIG. 1 and 4 is suggested. If using rigid pipe, be sure
to allow a minimum of 1-1/2" clearance under the fil
ter for sump removal when changing the filter car
tridge.
4. Use the plumbing procedures on pages 5 and 6 if
using compression fittings. Follow procedures on
pages 6 and 7 for sweat copper and threaded pipe
installations. Be sure water flow is into the filter in
let side, and from the outlet side, to the faucet.
5. Before turning on the water supply, remove the
sump from the filter head and install the filter cartridge
(see below).