CEILING CONCEALED TYPE AIR CONDITIONER
Operation & Installation
Manual

Table of Contents

Installation Procedure
Installation Check and Trial Run
No. 0010573668
A
Please read this operation manual before using the air conditioner.
Please keep this manual carefully and safely.
1-2
3-5
6-7
8
9
10-11
12-17
18

Advertisement

loading

Summary of Contents for Haier AE072FCBKA

  • Page 1: Table Of Contents

    Important Points of Safety Trouble Shooting When Fault Occurs Notice to Users Installation Precautions Installation Procedure Installation Check and Trial Run No. 0010573668 Please read this operation manual before using the air conditioner. Please keep this manual carefully and safely. 10-11 12-17...
  • Page 2: Cautions

    Cautions Installation Check and Trial Run Check if the drain pipe and connection wires are arranged properly. The drain pipe shall be put below. The connection wire shall be put above. Be sure to wrap the drain pipe (especially the indoor part and the part inside the machine) with thermal ins- ulating materials.
  • Page 3: Cautions

    Installation Procedure Pipe expansion dimensions as follows: Pipe diameter ÿ Size A (mm) Incorrect Correct 6.35 mm (1/4 " ) 0.8 ~ 1.5 9.52 mm (3/8 " ) 1.0 ~ 1.8 12.7 mm (1/2 " ) 1.2 ~ 2.0 Slope Damage Bur Partial Overlong 15.88 mm (5/8 "...
  • Page 4: Important Points Of Safety

    Important Points of Safety The following four important points of safety and suggestions should be paid great attention: Warning: Misuse may cause fatal result such as death or serious injury etc. Attention: Misuse may cause human injury or damage of machine, in some case fatal results.
  • Page 5 Installation Procedure Original concrete slab Use hole hinge, hole plunger or hole bolt. Steel reinforcement structure Hanging bolt Use steel angle or new support steel angle directly. Suspension screw Hanging of the indoor unit Fasten the nut on the suspension screw and then hang the suspension screw in the T slot of the suspension part of the unit.
  • Page 6: Important Points Of Safety

    Use M8 or M10 suspension screws (4, prepared in the field) (when the suspension screw height exceeds 0.9 m, M10 size is the only choice). These screws shall be installed as follows with space adapting to air conditioner overall dimensions according to the original building structures.
  • Page 7: Trouble Shooting

    (terminal color is white), the distance between air duct outlet and air conditioner outlet is no more than 0.5m; when connect to long air duct, using middle static terminal (terminal color is red), the distance between air duct outlet and air conditioner outlet could be within 5m at this point.
  • Page 8 Trouble Shooting During DRY operation, there is no air sent out or fan speed cant be changed. In HEAT mode, the outdoor unit This occurs during removal of the frost generates water or steam. (in defrosting operation) on the radiator of outdoor unit.
  • Page 9: When Fault Occurs

    If, after the above checks and the corresponding corrective actions, the system remains abnormal operation, or the following facts appear, please turn off the air conditioner and then contact the local authorized service center. Frequent open of fuse or breaker.
  • Page 10: Notice To Users

    Improper installation will cause heating and fire etc. accidents. When setting or moving the air conditioner do not let the air and things alike get into the refrigeration system except the specified refrigerant. If air and other things enter, abn- ormal high pressure will occur, which easily cause break and body injuries etc.