Content of gas gauge data
Name
Function
RS
The Sense Resistor Value [mill ohm]
CTRL
Device Control Register [Hex]
MODE
Device Control Register [Hex]
AR
At Rate [mA]
ARTTE
At Rate Time-to Empty [min]
TEMP
Reported Temperature [K]
VOLT
Reported Battery Voltage [mV]
FLAGS
Status Flags [Hex]
RSOC
Relative Start-of-Charge [%]
NAC
Nominal Available Capacity [mAh]
CACD
Discharge Compensated NAC [mAh]
CACT
Temperature Compensated CACD [mAh]
LMD
Last Measured Discharge [mAh]
AI
Average Current [mA]
TTE
Time-to-Empty [min]
TTF
Time-to-Full [min]
SI
Standby Current [mA]
STTE
Standby Time-to-Empty [min]
MLI
Max Load Current [mA]
MLTTE
Max Load Time-to-Empty [min]
SAE
Available Energy [mWh]
AP
Average Power [mW]
TTECP
Time-to-Empty At Constant Power [min]
CYCL
Cycle Count Since Learning Cycle [cycles]
CYCT
Cycle Count Total [cycles]
CSOC
Compensated State-of-Charge [%]
1-20 (No.MA272)
Comment
not used
not used
TEMP contain the reported die temperature.
VOLT contain the reported battery voltage measured on the BAT pin.
RSOC reports the nominal available capacity as a percentage of the
last measured discharge value (LMD).
NAC increments during charge(Vsrp > Vsrn) if Voltage > EDVF
threshold and decrement during discharges (Vsrp > Vsrn).
CACD reports available capacity in the battery.
CACT reports available capacity in the battery, compensated for
both discharge rate and temperature.
LMD is the measured discharge capacity of battery from full to empty.
AI reports the magnitude of the average current through the sense
resistor
TTE reports calculated time-to-empty at the measured discharge rate.
TTF reports calculated time-to-full at the measured charge rate.
SI reports measured standby current through the sense resistor.
STTE reports calculated time-to-empty at the measured standby
current value.
MLI reports the measured Maximum load current through the sense
resistor.
MLTTE reports calculated time-to-empty in minutes at the Maximum
measured discharge rate.
SAE is the calculated energy available from the battery.
AP is the calculated power delivered during a discharge.
TTECP is the time-to-empty on minutes with a constant power load.
CYCL is the cycle count since the learning cycle.
CYCT is the cycle count since a full reset.
OSOC reports the compensated available capacity as a percentage
of the last measured value(LMD).