Hitachi Relion 670 Series Product Manual page 181

Line differential protection
Hide thumbs Also See for Relion 670 Series:
Table of Contents

Advertisement

Line differential protection RED670
Version 2.2
Software options
No option
High impedance differential protection - 3 blocks
Line differential protection 6 CT sets
Line differential protection 6 CT sets + transformer
Line differential protection for 3 CT sets, 2-3 line ends
Phase segregated scheme communication
Out-of-step protection
Pole slip protection
Stub protection
High speed distance protection, quad and mho characteristic
Sensitive directional residual overcurrent and power protection
Scheme communication for residual overcurrent protection
Directional power and voltage restrained overcurrent protection
Average power transient earth fault protection
Overexcitation protection - 2 winding
Frequency protection - line
General current and voltage protection
Fuse failure supervision based on voltage difference
Autorecloser, 1 circuit breaker
Autorecloser, 2 circuit breakers
Control functionality for up to 10 objects
Control functionality for up to 15 objects
Through fault monitoring
Harmonic monitoring
IEC 62439-3 Parallel redundancy protocol
IEC 62439-3 High-availability seamless redundancy
Rapid spanning tree protocol
IEC 61850-9-2 Process Bus communication, 8 merging units
Synchrophasor report, 8 phasors
1)
All fields in the ordering form do not need to be filled in.
2)
Only one Line differential protection has to be selected.
3)
A04, A06 and A34 only for B33
4)
Only for B33/A42/ B42
5)
Only for C42
6)
Only for B33/B42; 1 block included as basic
7)
1 block already included
8)
Only for A42/C42, 1 block already included
9)
Only for B33/B42, 2 blocks already included
10) H37 only for A42/C42, H38 only for B33/B42
11) Options P23, P24 and P25 require two SFPs placed in pairs.
12) This functionality requires accurate time synchronization, therefore either Precision Time Protocol (PTP) Time synch or GTM or IRIG-B will be required.
Language
First local HMI user dialogue language
HMI language, English IEC
Additional local HMI user dialogue language
No additional HMI language
HMI language, English US
1)
Additional 2nd languages are continuously being added. Please get in touch with local Hitachi Power Grids sales contact.
Casing
1/2 x 19" rack casing, 1 TRM
3/4 x 19" rack casing, 1 TRM
3/4 x 19" rack casing, 2 TRM
1/1 x 19" rack casing, 1 TRM
1/1 x 19" rack casing, 2 TRM
Hitachi Energy
© 2017 - 2022 Hitachi Energy. All rights reserved
Ordering no
#3
X00
1MRK004001-AB
A02
1MRK004001-AD
A04
1MRK004001-AF
A06
1MRK004001-AU
A34
1MRK004001-XD
B05
1MRK004001-BW
B22
1MRK004001-VU
B24
1MRK004001-VK
B27
1MRK004001-XA
B35
1MRK004001-CT
C16
1MRK004001-VN
C34
1MRK004001-VL
C35
1MRK004001-UY
C54
1MRK004001-DC
D03
1MRK004001-ED
E04
1MRK004001-FA
F01
1MRK004001-HC
G03
1MRK004001-GD
H04
1MRK004001-GE
H05
1MRK004001-GW
H37
1MRK004001-GY
H38
1MRK004001-KR
M22
1MRK004001-KS
M23
1MRK004001-PP
P23
1MRK004001-PR
P24
1MRK004001-PY
P25
1MRK004001-PT
P30
1MRK004001-PV
P32
Selection for
position #3
Ordering no
#4
1MRK002930-AA
B1
X0
1MRK002920-UB
A12
Selection for
B1
position #4
Ordering no
#5
1MRK000151-VA
A
1MRK000151-VB
B
1MRK000151-VE
C
1MRK000151-VC
D
1MRK000151-VD
E
Selection for
position #5
1MRK 505 379-BEN R
Notes and rules
1)
2)
3)
,
4)
5)
6)
4)
4)
7)
8)
9)
10)
11)
12)
Notes and rules
1)
Notes and rules
181

Advertisement

Table of Contents
loading

This manual is also suitable for:

Relion red670

Table of Contents