Simultaneous receiving can be done with not only specified one transceiver but many units if
only the receiving channel and CTCSS code meet on RX side. Therefore, one person of a group
can speak to all.
The TX/RX frequencies and channels are same. CTCSS code is provided with 38 codes from
67Hz to 250.3Hz (refer to
14.1. FREQUENCY
TABLE).
Vibrator call
As for the vibrator operation, the mode of RX side should be preset to make the operation
available. The vibrator function is available even among different models. (The vibrator can be
operated even by the calling sound or voice of the unit which is not equipped with the vibrator
function.) The calling from other models can activate the vibrator of KX-TR 320EXS/F.
Operation Input: Channel settings, CTCSS code settings, other modes settings / Compander:
Compressor/Expander
18. BLOCK DIAGRAM