OPERATION/DISPLAY

  • ON/OFF
    • Switches between ON and OFF.
  • Operation mode switching
    • Switches between Cool/Dry/Fan/Auto/Setback/Heat.
  • Hold
    • Switches between enable and disable the Hold function.
    • If the Hold function is enable, the following functions will be prohibited.
    • ON/OFF timer/Schedule (Weekly timer) /Auto return/Auto-OFF timer
  • Temperature setting
    • Changes the set temperature.
    • Set temperature range varies depending on the indoor unit model.
  • Fan speed setting
    • Changes fan speed.
    • Available fan speeds vary depending on the model.
  • Air flow direction setting
    • Changes airflow direction.
    • Available airflow directions vary depending on the model.
  • Louver setting
    • Switches between louver ON/OFF.
  • Ventilation equipment control
    • Interlocked setting and interlocked operation setting with City Multi Lossnay units can be performed.
    • The Stop/Low/High settings of the ventilation equipment can be controlled.
  • Main display mode setting
    • The Main display can be displayed in two different modes: "Full" and "Basic."
  • B&W inversion
    • The colors of the display can be inverted, turning white background to black and black characters to white.
  • Clock *2
    • Date (year/month/day) and time (hour/minute) can be set.
    • The set time as well as the day of the week will be displayed on the Main display.
    • It is also possible for the time to not display on the main display.
    • The clock can be displayed in 12-hour format (AM/PM before or after the time) and 24-hour format.
  • Daylight saving time
    • The start/end time for daylight saving time can be set.
    • The daylight saving time function will be activated based on the setting contents.
  • Room temp. display
    • The room temperature display can be enabled or disabled.
  • Error information
    • When an error occurs, an error code and the unit address appear.
    • The air-conditioning unit model, serial number, and contact number can be set to appear when an error occurs. (The above information needs to be entered in advance.)
  • Filter information
    • A filter sign will appear when it is time to clean the filter.
  • Remote controller information
    • The version of the remote controller can be checked.

*1 This function is active only for the units that support the function.

*2 The clock is accurate within 45 seconds per month (at the temperature of 77°F [25ºC]).
The clock is backed up for 3 days.

SCHEDULE AND TIMER SETTING

  • Timer
    • ON/OFF timer
      • Turns ON and OFF daily at a set time.
      • Time can be set in 5-minute increments.
      • It is also possible to set the ON time only or the OFF time only.
    • Auto-OFF timer
      • Turns off the unit after a certain period of operation.
      • Operation time can be set to a value from 30 to 240 minutes in 10-minute increments.
  • Weekly timer
    • Weekly ON/OFF times and set temperatures can be set.
    • Time can be set in 5-minute increments. Up to 8 schedule patterns can be set per day of the week.
    • Not valid when the ON/OFF timer is set.

RESTRICTION SETTINGS

  • Allows/disallows local operation
    • The following operation can be prohibited by applying certain settings on the centralized controller: ON/OFF, operation mode, set temperature, filter sign reset, air direction, fan speed and timer.
    • While an operation is prohibited, the operation icon lights up (only on the Main display in the "Full" mode).
  • Operation lock
    • The following operations can be prohibited: Sensing Location, ON/OFF, Mode, Set temp., Menu, Fan, Louver, Vane, or Hold
  • Temperature range restriction
    • The room temperature range for each operation mode can be restricted.
  • Auto return
    • The units operate at the preset temperature after a designated period.
      • Time can be set to a value from 30 to 120 minutes in 10-minute increments.
    • Not valid when the temperature setting range is restricted.
  • Password
    • Administrator password (required for schedule setting etc.) and Maintenance password (required for test run and function setting etc.) can be set.

SYSTEM EXAMPLE

*When a PAR-40MAAU is connected to a group, no other MA remote controllers can be connected to the same group.

System Example

MISCELLANEOUS ITEMS

  • Language Selection
    • Select the display language from the following 3 languages.
      • English, French, Spanish
  • Brightness Contrast
    • The brightness of the LCD can be adjusted. The contrast of the LCD can be adjusted.
  • Manual Vane Angle *1
    • Fixes the vane position for each air outlet.
  • Service *1
    • Contains Test run, Function setting, Request code, and Error history.
  • 3D i-see Sensor
    • Settings for 3D i-see Sensor can be made.

ENERGY SAVING OPTION

  • No occupancy energy save
    • Requires 3D i-see sensor on applicable indoor units
  • Room Occupancy energy save
    • Requires 3D i-see sensor on applicable indoor units
  • No occupancy Auto-OFF
    • Requires 3D i-see sensor on applicable indoor units
  • Setback Mode

*1 This function is active only for the units that support the function.
*2 The clock is accurate within 45 seconds per month (at the temperature of 77°F [25ºC]).

The clock is backed up for 3 days.

DIMENSIONS

Front View
Front View

Side View
Side View

Rear View
Rear View

Unit: mm [in.]

COMPATIBILITY CHART

CITY MULTI® M-Series P-Series
PMFY-NBMU Yes MFZ-KA MAC-334 PCA Yes
PEFY-NMU Yes MFZ-KJ MAC-334 PEA Yes
PEFY-NMAU Yes MSZ/Y-A No PEAD Yes
PEFY-NMHSU Yes MSZ/Y-D NA: No NA-8: MAC-334 PKA Yes
PEFY-NMLU Yes MS-WA No PLA Yes
PEFY-NMSU Yes MSZ-FD No PVA Yes
PLFY-NAMU Yes MSZ-FE 09(12)NA: No
09(12)NA-8: MAC-334
18 NA: Yes1
PLFY-NBMU Yes MSZ/Y-GE 06(-18)NA: No
NA-8: MAC-334
NA-9: MAC-334
GE24NA: MAC-334
PLFY-NCMU Yes MSZ/Y-GL MAC-334
PLFY-NEMU Yes MSZ-FH MAC-334
PLFY-NFMU Yes MSZ-HE No
PLFY-NLMU Yes MSZ-HM MAC-334
PCFY-VKM Yes MVZ-AA4 Yes
PCFY-NGMU Yes MVZ-AA7 Yes
PCFY-NKMU Yes SVZ-KP Yes
PFFY-NEMU Yes SEZ-KD No
PFFY-NRMU Yes SEZ-KD4 Yes
PVFY-E00 Yes SLZ-KA Yes
PVFY-NAMU Yes SLZ-KF Yes
PKFY-NAMU Yes MLZ-KP MAC-334
PKFY-NFMU Yes Note: MAC-334 indicates that the unit requires a MAC-334IF-E Adapter in order
to use the PAR-40MAAU
PKFY-NGMU Yes
PKFY-NBMU Yes
PKFY-NHMU Yes
PKFY-NKMU Yes

SPECIFICATIONS

Product size
(W x H x D)
In.
(mm)
4 3/4 x 4 3/4 x 0.57
(120 x 120 x 14.5)
Net Weight Lbs. (kg) 9/16
(0.25)
Rated Power Supply Voltage 12 VDC
(supplied from indoor units)
Power Consumption W 0.3
Usage Environment Temperature: 0 to 40º C (32 to 104º F)
Humidity: 30 to 90%RH (with no condensation)
Material Panel PMMA
Main body PC + ABS
Sound Pressure Level dB(A) <70 [A-weighted sound pressure level]

*1 Per Machinery Directive 2006/42/EC

© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Specifications are subject to change without notice.
M_ Submittal_PAR-40MAAU 03-2020

1340 Satellite Boulevard. Suwanee, GA 30024
Toll Free: 800-433-4822 www.mehvac.com

Videos

Mitsubishi PAR-40MAAU - Basic Operation video

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Mitsubishi PAR-40MAAU Deluxe MA Remote Controller User Guide

Advertisement

Need Assistance?

Do you have a question about the PAR-40MAAU that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents