Installation Requirements; Tools And Parts; Location Requirements - KitchenAid Architect Series II KHMS2050SSS Installation Instructions Manual

Kitchenaid architect series ii khms2050sss: install guide
Hide thumbs Also See for Architect Series II KHMS2050SSS:
Table of Contents

Advertisement

This oven is set for recirculation installation. For external (wall or roof) venting, see "Venting Design Specifications" section.

Tools and Parts

Tools Needed
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Measuring tape
Pencil
Masking tape or thumbtacks
Scissors
T10 TORX
®†
screwdriver
No. 3 Phillips screwdriver for
1/4-20 x 3" round-head bolts
Electric drill
3/16" (5 mm) and 3/8"
(9.5 mm) drill bits
3/4" (19 mm) hole saw
Parts Supplied
For information on reordering, see "Replacement Parts" section.
NOTE: The hardware items listed here are for wood studs. For
other types of wall structures, be sure to use appropriate
fasteners.
A
B
C
H
I
A. 1/4-20 x 3" round-head bolts (4)
B. 1/4-20 x 3" flat-head bolts (2)
C. Washers (2)
D. Toggle nuts (4)
E. 1/4" x 2" lag screws (4)
F. Mounting screws (3)
G. Power supply cord bushing (1)
H. Damper assembly (for wall or roof
venting)
I. Vent deflector (for wall or roof
venting)
NOTE: Depending on model, aluminum grease filter and charcoal
filter may be combined.
Materials needed
Standard fittings for wall or roof venting. See "Venting Design
Specifications" section.
†®TORX is a registered trademark of Textron Innovations Inc.
2

INSTALLATION REQUIREMENTS

Diagonal cutting pliers
Stud finder
7/16" socket wrench
(or box wrench) for 1/4" x 2"
lag screws
1½" (4 cm) diam. hole drill
bit for wood or metal
cabinet
Keyhole saw
Caulking gun and
weatherproof caulking
compound
Duct tape
D
E
F
Not Shown:
Upper cabinet template
Mounting plate (attached to
back of oven)
Aluminum grease filters
Charcoal filters (Depending
on model, charcoal filters
may not be included. See
Use and Care Guide.)
Check the opening where the microwave oven will be installed.
The location must provide:
Minimum installation dimensions. See "Installation
Dimensions" illustration.
Minimum one 2" x 4" (50.8 x 101.6 mm) wood wall stud and
minimum 3/8" (9.5 mm) thickness drywall or plaster/lath within
cabinet opening.
Support for weight of 150 lbs (68 kg), which includes oven and
items placed inside the oven and upper cabinet.
Grounded electrical outlet inside upper cabinet. See
"Electrical Requirements" section.
NOTES:
If installing the oven near a left sidewall, make sure there is at
least 3" (7.6 cm) of clearance between the wall and the oven,
so that the door can open fully.
Some cabinet and building materials are not designed to
withstand the heat produced by the oven for cooking. Check
with your builder or cabinet supplier to make sure that the
materials used will not discolor, delaminate or sustain other
damages.
Special Requirements
For gas cooktop, we recommend that combined cooking
surface rating to not exceed 50,000 BTU/hr.
The oven is set for recirculation mode. For external (wall or
roof) venting, see "Venting Design Specifications" section.
G
For Wall Venting Installation Only:
The 12" x 4" (30.5 x 10.2 cm) cutout area (see "Wall Venting
Installation Only" in the "Mark Rear Wall" section) must align
with the wall damper vent on the back of the oven (see "Wall
Venting Installation Only" in the "Convert Oven to External
Venting" section).
Cutout must be free of any obstructions so that the vent tube
fits properly, and the damper blade opens freely and fully.
For Roof Venting Installation Only:
If using rectangular to round transition piece, 3" (7.6 cm)
clearance needs to exist above the oven so that the damper
blade can open freely and fully. See "Rectangular to Round
Transition" illustration in "Venting Design Specifications"
section.

Location Requirements

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Khms2050sbt - architect ii 30" 2.0 cu. ft. 1,200 watt

Table of Contents