Panasonic RG-R811A Installation Instructions Manual

Panasonic RG-R811A Installation Instructions Manual

Advertisement

Model No.
RG-R811A
GENERAL SAFETY INFORMATION
To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always
observe the following safety precautions.
The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage
caused when the denotation is disregarded and improper use is performed.
WARNING
CAUTION
The following symbols are used to classify and describe the type of instructions to be observed.
This symbol is used to alert users to a specific operating procedure that must be followed in order to
operate this unit safely.
This symbol is used to alert users to a specific operating procedure that must not be performed.
This symbol is used to alert users not to disassemble the equipment.
This symbol is used to alert users to make sure of grounding when using the equipment with the grounding
terminal.
READ AND SAVE THESE INSTRUCTIONS
Thank you for purchasing this Panasonic product.
Please read these instructions carefully before attempting to
install, operate or service the Panasonic product. Please
carefully read the "GENERAL SAFETY INFORMATION".
Failure to comply with instructions could result in personal
injury or property damage. Please explain to users how to
operate and maintain the product after installation and this
manual should be presented to users. Please retain this
manual for future references.
Denotes a potential hazard that could result in serious injury or death.
Denotes a hazard that could result in minor injury.
Denotes a hazard that could result in property damage.
INSTALLATION INSTRUCTIONS
See page 12 for "Panasonic Warranty Sheet".
Ventilating Fan
R8 1 1 A1 4 2 0 A

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic RG-R811A

  • Page 1 READ AND SAVE THESE INSTRUCTIONS Thank you for purchasing this Panasonic product. Please read these instructions carefully before attempting to install, operate or service the Panasonic product. Please carefully read the “GENERAL SAFETY INFORMATION”. Failure to comply with instructions could result in personal injury or property damage.
  • Page 2 GENERAL SAFETY INFORMATION (CONTINUED) WARNING To reduce the risk of fire, electric shock or injury to persons, observe the following: Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
  • Page 3 GENERAL SAFETY INFORMATION (CONTINUED) Always disconnect the power source before working on or near the fan, motor or junction box. Protect the supply wiring from sharp edges, oil, grease, hot surfaces, (Cooking area) chemicals or other objects. Do not install above or inside this area Do not kink the supply wiring.
  • Page 4: Supplied Accesories

    SUPPLIED ACCESORIES Installation instructions/ Grille Warranty sheet 3 inch duct reducer (optional part) Machine Self-drilling screw screw (M4X8) DIMENSIONS Unit: inches (mm) 1 1/2 (37) 1 3/8 (32.6) 2 7/8 (71.4) 5 5/8 (143) 13 (330) Part name Part name Blade Pick-A-Flow™...
  • Page 5: Wiring Diagram

    WIRING DIAGRAM Fan body Junction box Power switch Main control circuit Black Live (Fan) AC 120 V 60 Hz Neutral White (Power supply) Main control circuit motor (Ground wire) Green FEATURES These products employ innovative, state-of-the-art technologies that provide a number of customizable unique features that lead to improved indoor air quality.
  • Page 6: Installation (Retrofit)

    INSTALLATION (RETROFIT) If you require use of the 3 inch duct WARNING IMPORTANT: reducer (optional accessory), use the Remove the tape placed on the damper and following method: adaptor before installation. Failure to do so will cause the product to work inefficiently and Disconnect power supply before create a loud noise.
  • Page 7 INSTALLATION (RETROFIT) (CONTINUED) Install circular exhaust duct Circular exhaust duct Conduit Flex-Z Fast™ bracket Joist Joist Remove screw from junction box cover to remove the knock-out hole and secure conduit or stress relief to junction box knock-out hole. Knock-out hole Install the circular exhaust duct and secure it with clamps or ties and seal it with mastic or Adaptor...
  • Page 8 INSTALLATION (RETROFIT) (CONTINUED) Insert fan body Insert fan body and slide into adaptor assembly using the guide parts until you hear a click from Joist the hook. Joist Guide parts Guide parts Secure fan body Sealing Joist Drywall Plug connector Flange Joist Joist...
  • Page 9 INSTALLATION (NEW CONSTRUCTION) WARNING If you require use of the 3 inch duct IMPORTANT: reducer (optional accessory), use the Remove the tape placed on the damper and following method: adaptor before installation. Failure to do so will cause the product to work inefficiently and Disconnect power supply before create a loud noise.
  • Page 10: Installation (New Construction)

    INSTALLATION (NEW CONSTRUCTION) Insert fan body Joist Assembled view detail Insert fan body and slide into adaptor Guide parts assembly using the guide parts until Hook Guide parts you hear a click from the hook. Secure fan body Joist When the flange overlaps Flex-Z Fast™ bracket, secure it by using 2 self-drilling Plug connector screws.
  • Page 11: Practical Guide To Installation

    Mechanically connect duct to termination attic. Panasonic fans do not create excessive heat and seal with mastic or approved foil which is a common problem with recessed light faced tape fixtures and some competitor’s fan/light combination.
  • Page 12 USA, in the event of defects in material or workmanship in accordance to the following: Service in the USA, can be obtained during the warranty period by contacting the selling Distributor or Panasonic Customer Call Center at 1-866-292-7299, toll free.

Table of Contents