Panasonic DH-4MS1 Operating Instructions Manual page 10

Electric home shower
Table of Contents

Advertisement

Available languages

Available languages

4 Earth Rod
The Unit must be earthed.
WARNING
Improper grounding could cause electric shock.
• The Unit must be earthed.
• Earth Rod fixing procedure. Select suitable place to bury the optional Earth Rod (DQ-6H) for at least 70 cm below ground surface.
• Ensure that the ground resistance is less than 100 Ω. If it is not, drive the Rod deeper into ground surface or use 2 or 3 Rods.
Burying tool
Earth Rod
Ground
Surface
5. Piping installation procedure
1 Place Rubber Packing between Filter Body Assembly and Flexible Pipe.
Do not use Piping Tape. Tighten it by Spanner firmly.
2 Place Rubber Packing between Filter Body Assembly and Main Body.
Do not use Piping Tape. Tighten it by hand firmly.
3 Place Rubber Packing between Shower Hose and Main Body.
Do not use Piping Tape. Tighten it by hand firmly.
4 Place Rubber Packing between Shower Hose and Shower Head.
Do not use Piping Tape. Tighten it by hand firmly.
5 The Filter Body Assembly should be placed in the front direction of the Unit.
Do not share the inlet or outlet pipe of Home
Shower Unit with other outlets.
The pressure may drop due to water being
WARNING
drawn off at other point. The shower water
temperature may become very hot.
Avoid using dirty water as it may affect
CAUTION
heater performance and other components.
Make sure no water leaks from pipe connection.
NOTE:
When glue is used for external piping connection, must wait
NOTE:
for the glue to dry before proceed to test run with water.
6. How to fix the Front Plate
1 Make sure the Power Selector Knob on Front Plate and it is at
"Off" position.
2 Make sure the Rotary Shaft and the D-Cut position is located
as shown (Off condition).
3 Close the Front Plate of the unit according to the sequence as
illustated.
4 Push in the Power Selector Knob until it is fully insert
<Power Selector Knob can not be inserted is Step 1 and
step 2 is not done accordingly>
5 Please ensure to rotate the Power Selector Knob clockwise until "High"
and counter clockwise until "Off" to ensure the knob is fully inserted to
the Power Knob Cap slot inside.
6 Fix the Screw at the bottom of the Unit.
Note:
1. Do not push the ELB Test Button during fixing the Front Plate.
2. Do not apply extreme force to insert the Power Selector Knob
during fixing the Front Plate because it will damage the switch
inside the Unit.
(Bevel Style) )
70 cm at least
70 cm at least
3
Press
Front
Plate
- 10 -
(Parallel Style)
Connection
70 cm at least
About 2 m
Shower Head
Main Body
4
3
Rubber
Packing
Filter Body
Shower
Assembly
Hose
Parts not
included
Use flexible
pipe minimum
length 150 mm
Lo
Off
Power Selector
ELB Test
ELB Reset
Push On-Off
Push Up
Water Outlet
1
2
Lo
Med
L
N
Off
Hi
Power Selector Knob
"D-Cut" position
of Power Selector Knob
Back Plate
4
5
Counter
Clockwise
Clockwise
Lo
Med
Press
Off
Hi
Connection
About 2 m
Thread End
2
1
Med
Hi
5
DH-4MS1
Filter Body
Assembly
Water Inlet
Power Knob
Cap slot
"D-Cut" position
of Rotary Shaft
6
OUTL ET
INLE T
Screw

Advertisement

Table of Contents
loading