How To Use Electric Home Shower; How To Use - Panasonic DH-4NS3 Operating Instructions Manual

Electric home shower
Table of Contents

Advertisement

Available languages

Available languages

HOW TO USE ELECTRIC HOME SHOWER

1. HOW TO USE

1. Turn "On" the Main Water Valve.
2. Switch "ON" the Miniature Circuit Breaker (MCB) and the ON/OFF DP (double pole) Switch.
3. Push the ELB Reset Lever if it is down.
4. Turn Water Volume Knob to clockwise.
• Turning it clockwise increases the volume of water thus decrease the water temperature.
• Turning it anticlockwise decreases the volume of water thus increase the water temperature.
5. Press the Push On-Off Lever, water will start flowing from the Shower Head and the ELB light will turn red.
• To stop the water flow, press the Push On-Off Lever again (the position of the Push On-Off Lever
remains the same).
• This button controls both water and electricity supply to the set.
• Adjust to the desired shower condition by operating the Water Volume Knob and the Power / Temperature
Control Knob. Then the operation can be made easily by pushing the Push On-Off Lever only.
CAUTION
6. Temperature setting
DH-4NS3 & DH-4NP1
(a) The shower temperature can be gradually controlled by setting the Power Control Knob to the desired
position.
(b) If you turn the Power Control Knob clockwise the shower temperature will go up, reaching the highest
temperature at "High".
The temperature can be gradually controlled.
(c) If the Power Control Knob is at "Off" position, the water temperature will remain at inlet temperature.
(d) In case of continuous usage at high temperature setting, water temperature will increase and it may
cause the control device in the set to activate temporarily resulting water temperature to drop.
DH-4NTP1
(a) The shower temperature can be gradually controlled by setting the Temperature Control Knob to the
desired position.
(b) If the Temperature Control Knob is turned clockwise to orange zone, you can get comfortable water
temperature.
(c) If the Temperature Control Knob is at "Off" position, the water temperature will remain at inlet water
temperature.
(d) Control Lamp (orange) will light up when water temperature is stable at desired position.
(e) Control Lamp will turn off when water flow is too much, and it is beyond the controllable range.
(f) Reduce the water flow by turning the Water Volume Knob anticlockwise until Control Lamp is "On".
(g) In case of continuous usage at high temperature setting, water temperature will increase and it may
cause the control device to activate temporarily resulting water temperature to drop.
7. Select the preferred shower with the Shower Select Button. Please press the button fully.
Shower
Shower
Select
Head
Button
8. Shower Head can be set at various positions.
(a) Loosen the Shower Hanger Knob and adjust higher or lower.
Tighten the Shower Hanger Knob.
(b) Loosen the Shower Hanger Knob and the Shower Hanger can be
adjusted to the left or right. Tighten the Shower Hanger Knob.
(c) The angle of the Shower Head can be adjusted by moving the
Shower Head upward or downward.
Press Push On-Off Lever before and after each shower.
Press the Push On-Off Lever only. Do not pull.
Do not turn "On" and "Off" the Main Water Valve to operate
the shower Unit to avoid any possible damage.
For DH-4NP1 & DH-4NTP1 model only
To ensure Pump reliability, Push On-Off Lever must be
pressed before and after each shower.
Do not pull the Push On-Off Lever, press only.
Press
- 5 -
ELB: ON condition
ELB: OFF condition
Make sure push at the
center of Push On-Off
Lever only.
Note:
When stopping the water flow or change
water shower selection from Wide Shower
to Spot Shower, some water will continue
to drip from Shower Head for less than 2
minutes. This is normal due to some water
remain in the Shower Head and no
abnormality to the Unit.
Shower Hanger
Shower Hanger
Knob
(a)
Off
High
ELB
ELB Test
Push On-Off
ELB Reset
Push Up
DH-4NS3
Off
High
ELB
ELB Test
Push On-Off
ELB Reset
Push Up
DH-4NS3
Off
High
ELB
ELB Test
Push On-Off
ELB Reset
Push Up
DH-4NS3
ELB Lamp
Power Control Knob
Off
High
ELB
ELB Test
Push On-Off
ELB Reset
Push Up
DH-4NS3
ELB Lamp
Temperature
Control Knob
ELB Test
Push On-Off
ELB Reset
Push Up
DH-4NTP1
Control Lamp
(b)