1.1.12 COMPRESSOR removal
Precautions for exchange of compressor.
Do not allow moisture or debris to get inside refrigerant pipes during work.
Procedure for compressor removal.
1 Turn off the power
2 Remove the TOP PANEL, FRONT PANEL and CABINET RIGHT ASSY.
3 Fully close the 3Way valve (gas) and 2Way valve (liquid)
4 Collect the refrigerant from the 3Way valve.
Start the following work after completely collecting the refrigerant.
Do not reuse the refrigerant that has been collected.
COVER - F
Remove the COVER-B, F, H, V, K.
Remove the TERMINAL COVER
COVER - K
COVER - H
COVER - B
Remove the connectors.
[R(U) : RED, T(W) : BLACK, S(V) : WHITE]