• Check if the voltage indicated on the appliance corresponds to the local power voltage before you connect the appliance� • If the power cord is damaged, you must have it replaced by Philips, a service center authorized by Philips, or similarly qualified persons in order to avoid a hazard�...
Page 22
• Do not place the appliance directly below an air conditioner to prevent condensation from dripping onto the appliance� • Only use the original Philips filters specially intended for this appliance� Do not use any other filters� • Combustion of the filter may cause irreversible human hazard and/ or jeopardize other lives�...
• Do not use the filter unauthorized by Philips in order to make sure normal running of the appliance, the air purification performace and the safety of the filter material�...
Your air disinfector Congratulations on your purchase, and welcome to Philips! To fully benefit from the support that Philips offers, register your product at www�philips�com/welcome� Product overview Control panel Air outlet Particle sensor Gas sensor NanoProtect filter Pro S3 (FY4150/01)
Air disinfector principle Disinfection factor: filtration Air disinfector is equipped with high efficiency HEPA filter can filtrate airborne bacteria efficiently� Air borne bacteria is mainly in the type of droplet and droplet nuclei (aerosol)� Large size droplets will naturally deposit� Droplet nuclei with size range from submicron to several microns, together with bacteria itself with size range from tens to hundreds of nanometers, these particles will all be captured by HEPA filter in the disinfector, which has high filtration ability to aerosol particles with size from as small as 3nm to several microns�...
Understanding Wi-Fi indicator Wi-Fi icon status Wi-Fi connection status Blink in orange Connecting to the smartphone Stable in orange Connected to the smartphone Blink in white Connecting to the server Stable in white Connected to the server Wi-Fi function disabled Wi-Fi connection Note: •...
4 Using the air disinfector Understanding the air quality light The air quality light automatically goes on Air quality light color Air quality level when the air disinfector is switched on, and lights up all colors in sequence� After Blue Good approximately 30 seconds, the air quality Blue-purple...
Turning on and off Note: • For optimum purification performance, close doors and windows� • Keep curtains away from the air inlet or air outlet� Put the plug of the air disinfector in the power socket� Touch to switch on the air disinfector� »...
Sleep mode ( Sleep Mode In Sleep mode, the air disinfector operates quietly at a low speed� After 3 seconds, the screen lights off� Switching the display indicator Note: The PM2�5 level is displayed on the central of the screen by default� Particulate Matter 2.5 PM2.5...
Checking the filter status • Touch the filter status check/reset button to check the filter service life status� » The percentage of remaining service life of the filter displays on the screen� Icon color Filter life indication Display (%) Blue Optimal service life 16-100 Filter status...
Cleaning the body of the air disinfector Regularly clean the inside and outside of the air disinfector to prevent dust from collecting� Wipe the fabric surface gently with a damp cloth� Use a soft, dry cloth to clean both the interior and exterior of the air disinfector and the air outlet�...
Cleaning the surface of the filter PM2.5 Clean surface of lter and long press to reset. Filter alert light status Action The filter cleaning alert Clean the surface of the filter with a vacuum displays on the screen Switch off the air disinfector and unplug from the power socket� Pull the back cover and remove it from the appliance�...
Replacing the filter Understanding the healthy protection lock This air disinfector is equipped with a filter replacement indicator to make sure that the filter is in optimal condition when the air disinfector is operating� When the filter need to be replaced, the filter replacement alert lights up red�...
Switch off the air disinfector and unplug from the power socket� Pull the back cover and remove it from the appliance� Pull the filter from the appliance� Remove all packaging materials of the new filter� Put the new filter into the appliance� Reattach the back cover�...
6 Storage Turn off the air disinfector and unplug from the power socket� Clean the air disinfector, particle sensor and the surface of the filter (see chapter “Cleaning and maintenance”)� Let all parts air dry thoroughly before storing� Wrap the filter in air tight plastic bags� Store the air disinfector, filter in a cool, dry location�...
Page 37
This is normal� However, if the appliance produces a burnt smell� smell even if removing filter, contact your Philips dealer or an authorized Philips service center� The filter may produce smell after being used for a while because of the absorption of indoor gases�...
Philips dealer� Order parts or accessories If you have to replace a part or want to purchase an additional part, go to your Philips dealer or visit www�philips�com/support� If you have problems obtaining the parts, please contact the Philips Consumer Care Center in your country (you can find its phone number in the worldwide guarantee leaflet)�...