Mitsubishi Electric CITY MULTI PEFY-M140VMA-A1 Operation Manual
Mitsubishi Electric CITY MULTI PEFY-M140VMA-A1 Operation Manual

Mitsubishi Electric CITY MULTI PEFY-M140VMA-A1 Operation Manual

Indoor unit
Hide thumbs Also See for CITY MULTI PEFY-M140VMA-A1:

Advertisement

Air-Conditioners
INDOOR UNIT
PEFY-M20,25,32,40,50,63,71,80,100,125,140VMA-A1
PEFY-M20,25,32,40,50,63,71,80,100,125,140VMAL-A1
OPERATION MANUAL
For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
BEDIENUNGSHANDBUCH
Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
MANUEL D'UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d'utilisation en entier avant de vous servir du climatiseur.
BEDIENINGSHANDLEIDING
Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de airconditioner gebruikt.
MANUAL DE INSTRUCCIONES
Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado para garantizar un uso seguro y correcto.
ISTRUZIONI DI FUNZIONAMENTO
Leggere attentamente questi istruzioni di funzionamento prima di avviare l'unità, per un uso corretto e sicuro della stessa.
ΕΓΧΕΙΡΙΔΙΟ ΟΔΗΓΙΩΝ ΧΡΗΣΕΩΣ
Για ασφάλεια και σωστή χρήση, παρακαλείστε διαβάσετε προσεχτικά αυτό το εγχειρίδιο χρήσεως πριν θέσετε σε λειτουργία τη μονάδα κλιματισμού.
MANUAL DE OPERAÇÃO
Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a unidade de ar condicionado.
DRIFTSMANUAL
Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug.
OPERATÖRSMANUAL
Läs den här bruksanvisningen noga innan luftkonditioneringsenheten används, för säker och korrekt användning.
IŞLETME ELKİTABI
Emniyetli ve doğru biçimde nasıl kullanılacağını öğrenmek için lütfen klima cihazını işletmeden önce bu elkitabını dikkatle okuyunuz.
РЪКОВОДСТВО ЗА ЕКСПЛОАТАЦИЯ
За безопасна и правилна употреба, моля, прочетете внимателно това ръководство преди експлоатацията на климатизатора.
INSTRUKCJA OBSŁUGI
Przed rozpoczęciem użytkowania klimatyzatora dokładnie przeczytaj niniejszą instrukcję, w celu uzyskania informacji na temat bezpiecznego i prawidłowego korzystania z urządzenia.
INSTRUKSJONSHEFTE
For sikker og riktig bruk, skal du lese dette instruksjonsheftet nøye før du betjener klimaanlegget.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
Для обеспечения правильного и безопасного использования следует ознакомиться с инструкциями, указанными в данном руководстве по эксплуатации, тщательным образом до того, как приступать к использованию кондиционера.
NÁVOD K OBSLUZE
Přečtěte si důkladně tento návod k obsluze před použitím klimatizační jednotky. Budete ji pak moci využívat bezpečně a správně.
NÁVOD NA POUŽITIE
Skôr, než začnete používať klimatizačnú jednotku, prečítajte si dôkladne návod na použitie, aby ste jednotku používali bezpečne a správne.
HASZNÁLATI KÉZIKÖNYV
A megfelelő és biztonságos használat érdekében, kérjük, hogy figyelmesen olvassa el a használati kézikönyvben leírtakat a légkondicionáló berendezés üzembe helyezése előtt.
UPORABNIŠKI PRIROČNIK
Za varno in pravilno uporabo pred uporabo klimatske naprave pazljivo preberite ta uporabniški priročnik.
MANUAL CU INSTRUCŢIUNI DE FUNCŢIONARE
Pentru o utilizare corectă şi sigură, vă rugăm să citiţi cu atenţie acest manual înainte de a pune în funcţiune unitatea de aer condiţionat.
PRIRUČNIK ZA RUKOVANJE
Radi sigurne i ispravne uporabe, temeljito pročitajte ovaj priručnik prije rukovanja klimatizacijskim uređajem.
<ORIGINAL>
<ORIGINAL>

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric CITY MULTI PEFY-M140VMA-A1

  • Page 1 <ORIGINAL> <ORIGINAL> Air-Conditioners INDOOR UNIT PEFY-M20,25,32,40,50,63,71,80,100,125,140VMA-A1 PEFY-M20,25,32,40,50,63,71,80,100,125,140VMAL-A1 OPERATION MANUAL For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. BEDIENUNGSHANDBUCH Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen. MANUEL D’UTILISATION Pour une utilisation correcte sans risques, veuillez lire le manuel d’utilisation en entier avant de vous servir du climatiseur.
  • Page 2 [Fig. A] <PEFY-M-VMA(L)-A1> ①: Air inlet on the rear ②: Air inlet at the bottom Ⓐ: Filter Air flow Lufteinlass auf der Rückseite Lufteinlass auf der Unterseite Filter Luftfluss Admission d'air par l'arrière Admission d'air par le bas Filtre Flux d'air Entrada de aire en la parte posterior Entrada de aire en la parte inferior Filtro...
  • Page 3 Wired remote controller Controller interface ⑤ ⑥ ③ ④ ② ① Function buttons ⑦ ⑧ ⑨ ⑩ ① [ON/OFF] button The functions of the function buttons change depending on the screen. Refer to the button function guide that appears at the bottom of the LCD for Press to turn ON/OFF the indoor unit.
  • Page 4 Display The main display can be displayed in two different modes: “Full” and “Basic.” The factory setting is “Full.” To switch to the “Basic” mode, change the setting on the Main display setting. ▌ Full mode ▌ Basic mode * All icons are displayed for explanation. ㉓...
  • Page 5: Table Of Contents

    EC Article 20 Information for end-users and Annex II. Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused. This symbol means that electrical and electronic equipment, batteries and accumulators, at their end- of-life, should be disposed of separately from your household waste.
  • Page 6: During Operation

    • This indoor unit should be installed in a room which is equal to or larger • Do not over-cool. The most suitable inside temperature is one that is than the floor space specified in the outdoor unit installation manual. within 5 °C of the outside temperature.
  • Page 7: How To Operate

    3. How to operate 3.1. Turning ON/OFF Caution: • Never expose your body directly to cool air for a long time. Excessive exposure to cool air is bad for your health, and should therefore be avoided. Press the [ON/OFF] button. •...
  • Page 8: Set Temperature

    3.3. Set temperature 3.4. Fan speed <Cool, Dry, Heat, and Auto (single set point)> Press the [F4] button to go through the fan Press the [F2] button to decrease the set speeds in the following order. temperature, and press the [F3] button to increase.
  • Page 9: The Smart Way To Use

    4. The smart way to use Even minimal steps to care for your air conditioner can help make its use far the cooling and heating seasons. (When profuse dust and dirt have more effective in terms of air-conditioning effect, electricity charges, etc. accumulated, clean the filter thoroughly.) Set the right room temperature Prevent intrusion of heat during air-cooling...
  • Page 10: Troubleshooting

    6. Troubleshooting When an error occurs, the following screen will appear and the operation LED will blink. Check the error status, stop the operation, and consult your dealer. Error code, error unit, refrigerant address, unit model name, and serial number will appear. The model name and serial number will appear only if the information have been registered.
  • Page 11: Installation, Transferring Works, And Checking

    The following symptoms are not air conditioner failures: cooling/heating operation. This is the sound of friction on the front panel and • The air blown out from the air conditioner can sometimes give off odors. This is other sections due to expansion and contraction caused by temperature due to cigarette smoke contained in the air of the room, the smell of cosmetics, change.
  • Page 12: Specifications

    8. Specifications PEFY-M-VMA(L)-A1 series M20VMA(L)-A1 M25VMA(L)-A1 M32VMA(L)-A1 M40VMA(L)-A1 M50VMA(L)-A1 Power source ~220-240 V 50Hz Cooling capacity /Heating capacity 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 Dimension (Height/Width/Depth) 250/700/732 250/700/732 250/700/732 250/900/732 250/1100/732 Net weight 21.0(20.0) 21.0(20.0) 21.0(20.5) 25.0(24.5) 30.0(29.0) Cooling /min 6.0-7.0-8.5-10.0 6.0-7.0-8.5-10.0 7.4-9.0-10.5-12.5 10.0-11.5-13.5-19.0 12.0-14.5-16.5-25.6 Airflow rate...
  • Page 13 64-63-62-61 Note: Recycle Rating condition Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality Cooling - Indoor: 27ºC DB, 19ºC WB materials and components which can be recycled and reused. Electrical and electronic Outdoor: 35ºC DB, 24ºC WB equipment, at their end-of-life, should be disposed of separately from your household Heating - Indoor: 20ºC DB, 15ºC WB...
  • Page 14 Wärmeleistung Отоплителна мощност Küttevõimsus Puissance calorifique Wydajność grzewcza Sildīšanas jauda Verwarmingsvermogen Kapaċità tat-tisħin Šildymo pajėgumas Potencia de calefacción Lämmitysteho Kapacitet grijanja Ⓔ Capacità di riscaldamento Topný výkon Varmekapasitet Θερμαντική ισχύς Vykurovací výkon Isıtma Kapasitesi Potência de aquecimento Fűtőteljesítmény Отопительная мощность Varmeydelse Zmogljivost ogrevanja Uppvärmningskapacitet...
  • Page 15 2022 (7) Manufacturer MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN AUTHORIZED REPRESENTATIVE IN EU: MITSUBISHI ELECTRIC EUROPE B.V.HARMAN HOUSE, 1GEORGE STREET, UXBRIDGE, MIDDLESEX UB8 1QQ, U.K. COMMERCIAL REGISTRATION NO.33279602 (8) Model number PEFY- PEFY-...
  • Page 16 MITSUBISHI ELECTRIC, PEFY-M20VMA-A1*, PEFY-M25VMA-A1*, PEFY-M32VMA-A1*, PEFY-M40VMA-A1*, PEFY-M50VMA-A1*, PEFY-M63VMA-A1*, PEFY-M71VMA-A1*, PEFY-M80VMA-A1*, PEFY-M100VMA-A1*, PEFY-M125VMA-A1*, PEFY-M140VMA-A1*...
  • Page 17 UK DECLARATION OF CONFORMITY MITSUBISHI ELECTRIC AIR CONDITIONING SYSTEMS EUROPE LTD. NETTLEHILL ROAD, HOUSTOUN INDUSTRIAL ESTATE, LIVINGSTON, EH54 5EQ, SCOTLAND, UNITED KINGDOM hereby declares under its sole responsibility that the air conditioners and heat pumps described below for use in residential, commercial and light-industrial environments:...
  • Page 18 <ENGLISH> <PORTUGUÊS> English is original. The other languages versions are translation of the original. O idioma original é o inglês. As versões em outros idiomas são traduções do idioma original. CAUTION CUIDADO • Refrigerant leakage may cause suffocation. Provide ventilation in accordance with EN378-1. •...
  • Page 19 <MAGYAR> Az eredeti szöveg angol nyelven íródott. A más nyelven írt változatok az eredeti szöveg fordításai. FIGYELMEZTETÉS • A hűtőközeg szivárgása fulladást okozhat. Gondoskodjon a szellőzésről az EN378-1 szerint. • Feltétlenül gondoskodjon a csövek szigeteléséről. A fedetlen csövek közvetlen megérintése égési vagy fagyási sérülést okozhat.
  • Page 20 ■ The serial number is indicated on the SPEC NAME PLATE. Sequential number for each unit: 00001–99999 Month of manufacture: A(1), B(2), C(3), D(4), E(5), F(6), G(7), H(8), J(9), K(10), L(11), M(12) Year of manufacture (western calender): 2014 → 4, 2015 → 5...
  • Page 24 This product is designed and intended for use in the residential, commercial and light-industrial environment. Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN KJ79P970H02_en...

Table of Contents