Toshiba RAV-GM561UTP-A Owner's Manual

Toshiba RAV-GM561UTP-A Owner's Manual

Indoor unit

Advertisement

Quick Links

R32
AIR CONDITIONER (SPLIT TYPE)
Owner's Manual
1 11 535 024 4
Indoor Unit
For commercial use
Model name:
4-way Cassette Type
RAV-GM561UTP-A
RAV-GM801UTP-A
RAV-GM1101UTP-A
RAV-GM1401UTP-A
RAV-GM1601UTP-A
English

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba RAV-GM561UTP-A

  • Page 1 AIR CONDITIONER (SPLIT TYPE) Owner’s Manual 1 11 535 024 4 Indoor Unit For commercial use Model name: 4-way Cassette Type RAV-GM561UTP-A RAV-GM801UTP-A RAV-GM1101UTP-A RAV-GM1401UTP-A RAV-GM1601UTP-A English...
  • Page 2: Table Of Contents

    – 1 – Contents Original instruction ADOPTION OF R32 REFRIGERANT Precautions for safety ....................3 This Air Conditioner has adopted a refrigerant HFC (R32) which does not destroy the ozone layer. Part names ........................7 According to IEC 60335-1 Wired remote controller ....................8 This appliance is not intended for use by persons (including Correct usage ........................
  • Page 3 • The qualified installer is a person who installs, maintains, relocates and removes the air conditioners made by Toshiba Carrier Corporation. He or she has been trained to install, maintain, relocate and remove the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such...
  • Page 4: Precautions For Safety

    – 3 – Precautions for safety  Warning indications on the air conditioner unit The manufacturer shall not assume any liability for the damage Warning indication Description caused by not observing the description of this manual. WARNING WARNING WARNING ELECTRICAL SHOCK HAZARD ELECTRICAL SHOCK HAZARD General Disconnect all remote...
  • Page 5 Operation • Before stacking the packing cartons for storage or transportation, heed the precautions written on the packing • Before opening the intake grille of the indoor unit or service cartons. Failure to heed the precautions may cause the stack to panel of the outdoor unit, set the circuit breaker to the OFF collapse.
  • Page 6 – 5 – • When the air conditioner is operated with a combustion • If the fan grille is damaged, do not approach the outdoor unit appliance in the same place, ventilate the room sufficiently. but set the circuit breaker to the OFF position, and contact Poor ventilation causes oxygen shortage.
  • Page 7 CAUTION • Do not leave flammable sprays or other flammable materials near the air conditioner, and do not spray flammable aerosol To disconnect the appliance from the mains supply. directly to the air conditioner. They may catch fire. • This appliance must be connected to the mains by means of a •...
  • Page 8: Part Names

    – 7 – Part names  Information on the transportation, handling and storage of the  Indoor unit carton Examples of indication on the carton Knob Earth screw Knob to open / close Provided in the electrical control box. Symbol Description Symbol Description...
  • Page 9: Wired Remote Controller

    Wired remote controller This remote controller can control the operation of up to 8 indoor units.  Display section In the display illustration below all the icons are shown. When the unit is in operation, only relevant icons will be displayed. Display When the leak breaker is turned on for the fi...
  • Page 10: Correct Usage

    – 9 – Correct usage  Operation section When the air conditioner is used for the fi rst time or when the setting is changed, follow the steps below. Settings are saved in Push each button to select a desired operation. memory and are displayed anytime the unit is turned on by pushing the button.
  • Page 11: Timer Operation

    Timer operation NOTE Three timer modes are available: (Setting of up to 168 hours is enabled.) • Auto Changeover Off timer : The unit stops when the set time is reached. • When in Auto Mode, the unit selects the operating mode (cooling, heating or fan only) based on the user set point Repeat Off timer : The unit stops daily when the set time is reached.
  • Page 12: Adjustment Of Wind Direction

    – 11 – Adjustment of wind direction For best cooling and heating performance, adjust the louvers (adjustment plates of up / down wind direction) appropriately. Cold air descends and warm air rises, so to heat a room tilt the louvers downward, and to cool a Unit select button room tilt them horizontally.
  • Page 13: Power Saving Mode

    Power saving mode Electrical control box Unit select button The power saving mode saves energy by limiting the maximum current which will effect cooling capacity that the unit can generate. When multiple indoor units are controlled with one • remote controller, louver direction can be set for each Refrigerant Power saving mode will stay in effect until it is button during operation.
  • Page 14: Self Clean Mode

    – 13 – Self clean mode Advanced settings This function is provided to dry the inside of the indoor unit by the FAN operation after running the cooling  How to set up swing type / dry / AUTO (cooling) mode to keep the indoor unit clean. The self clean time varies with the cooling / dry / Auto (cooling) operation time as follows.
  • Page 15  Setting the louver lock Standard swing Cyclic swing (Recommended for cooling) All four louvers swing simultaneously at the same All four louvers swing at different times like waves. angle. Push and hold the button (right side of the button) for at least 4 seconds while running is stopped.
  • Page 16: Maintenance

    – 15 –  Releasing the louver lock Maintenance Set “0000” in Step 4 of “Setting the louver lock”. WARNING mark disappears. * Steps 1 - 3 and 5, 6 of “Setting Cleaning the air fi lter and other parts of the air fi lter involves dangerous work in high places, so be sure to the louver lock”...
  • Page 17: Troubleshooting

    Check periodically Troubleshooting • If the unit is used for a long time, parts may deteriorate and cause malfunction or bad drainage of dehumidified water depending on the heat, humidity, or dust. Check the points described below before requesting repair. In addition to the usual maintenance, it is recommended that you have the unit checked and maintained by the dealer where •...
  • Page 18: Operations And Performance

    – 17 –  Confirmation and check  Confirmation of error log Operations and performance When an error occurred in the air conditioner, an error code When an error occurred on the air conditioner, the error log and indoor UNIT No. appear on the display part of the remote can be confirmed with the following procedure.
  • Page 19: Installation

    Installation Do not install the air conditioner in the following places Do not install the air conditioner in any place within 1 m from a TV, stereo, or radio set. If the unit is installed in such place, • noise transmitted from the air conditioner affects the operation of these appliances. Do not install the air conditioner near a high frequency appliance (sewing machine or massager for business use, etc.), •...
  • Page 20 – 19 – MEMO...
  • Page 21 MEMO – 20 –...
  • Page 22 – 21 – MEMO...

Table of Contents