Extractor hood LC97FMR60, LC98KMR60 User manual and installation instructions Register your product on My Siemens and discover exclusive ser- vices and offers. siemens-home.bsh-group.com/welcome The future moving in. Siemens Home Appliances...
en Safety Only use this appliance: Table of contents ¡ For extracting cooking vapour. ¡ In private households and in enclosed spaces in a domestic environment. INFORMATION FOR USE ¡ Up to an altitude of max. 2000 m above sea level. Safety .............. 2 Do not use the appliance: Avoiding material damage........
Page 3
Safety en WARNING ‒ Risk of poisoning! WARNING ‒ Risk of fire! Risk of poisoning from flue gases being Fatty deposits in the grease filters may catch drawn back in. Room-air-dependent heat-pro- fire. ducing appliances (e.g. gas, oil, wood or coal- ▶ Never operate the appliance without a operated heaters, continuous flow heaters or grease filter.
en Safety Incorrect repairs are dangerous. WARNING ‒ Risk of injury! ▶ Repairs to the appliance should only be Components inside the appliance may have carried out by trained specialist staff. sharp edges. ▶ Only use genuine spare parts when repair- ▶ Carefully clean the appliance interior. ing the appliance.
Avoiding material damage en 2 Avoiding material damage Condensation that flows back in may damage the ap- ATTENTION! pliance. Condensate may cause corrosion damage. The air extraction duct must be installed with a ▶ To prevent condensation from building up, switch on ▶...
Page 6
en Operating modes 4.2 Air recirculation mode The air which is drawn in is cleaned by the grease fil- ters and an odour filter, and conveyed back into the room. To bind odours in circulating-air mode, you must install an odour filter. The dif- ferent options for operating the appli- ance in circulating-air mode can be found in our catalogue.
Familiarising yourself with your appliance en 5 Familiarising yourself with your appliance 5.1 Controls You can use the control panel to configure all functions of your appliance and to obtain information about the operat- ing status. 5.2 Display Switching the appliance on or off Increasing the fan setting You can see the current setting values in the display.
Page 8
en Home Connect a The ventilation is automatically ended when the 6.15 Setting the PowerBoost position sensor detects no further change in the room air On some appliances, the filter cover can be adjusted to quality. an intermediate position. The intermediate position can a Automatic mode runs for a maximum of four hours.
Page 9
Home Connect en ¡ Operating the appliance on the appliance itself al- As soon as a software update is available, you will be ways takes priority. During this time it is not possible informed via the Home Connect app and will be able to to operate the appliance using the Home Connect start the software update via the app.
en Hob-based hood control 8 Hob-based hood control You can connect your appliance to a suitable hob and, ¡ Please note the safety precautions in the instruction in this way, control the functions of your appliance via manual for your appliance and ensure that they are the hob.
You can find out which accessories are available for your appliance in our catalogue, in the online shop or Long Life circulated air LZ10AFS00 from our after-sales service. set (flat hood) siemens-home.bsh-group.com Long Life circulated air LZ10AKS00 set (angled canopy hood) Accessories Order number...
Page 12
en Cleaning and servicing Accessories Order number Accessories Order number Clean Air Plus no-flue cir- LZ11AFV16 Clean Air Plus circulated LZ11AXC56 culated air set (flat hood) air set, external Clean Air Plus circulated LZ11AKI16 Clean Air Plus odour filter LZ11AKB16 air set (angled canopy (replacement) hood) Clean Air Plus odour filter...
Cleaning and servicing en Start the dishwasher. 13.4 Removing the grease filter Select a temperature of no more than 70 °C. Allow the grease filters to drain. WARNING ‒ Risk of injury! Risk of injury when opening and closing the hinges. Keep your hands away from the hinges. 13.6 Cleaning grease filters manually ▶...
2014/53/EU. appliance. A detailed RED Declaration of Conformity can be found online at siemens-home.bsh-group.com among the ad- ditional documents on the product page for your appli- ance. Only applies to Great Britain 2.4 GHz band (2400–2483.5 MHz): Max.
Installation instructions en 15.2 Safety clearances 15.4 Installation recommendation Comply with the safety clearances for the appliance. We recommend fitting the appliance such that the lower edge of the glass screen is in line with the lower edges of the adjacent wall-hung cabinets. Maintain the safety clearances to the hob.
en Installation instructions Risk of poisoning from flue gases being 15.5 Secure installation drawn back in. Follow these safety instructions when in- ▶ If an extractor hood with an open-flued heat stalling the appliance. production source is installed, the power WARNING ‒ Risk of poisoning! supply for the extractor hood must be Risk of poisoning from flue gases being provided with a suitable safety switch.
Page 17
Installation instructions en Grease deposits in the grease filter may catch If the appliance or the power cord is dam- fire. aged, this is dangerous. ▶ Never work with naked flames close to the ▶ Never operate a damaged appliance. appliance (e.g. flambéing). ▶...
Page 18
en Installation instructions 15.6 Instructions for the electrical 15.8 General information connection Follow these general instructions during the installation. ¡ For the installation, observe the currently valid build- In order to safely connect the appliance to the elec- ing regulations and the regulations of the local elec- trical system, follow these instructions.
Page 19
Installation instructions en Use a spirit level to align the appliance bracket hori- zontally and screw it firmly in place. Variant A: Flat extractor hood with flue cover Installing the appliance Remove the protective film from the rear. Once the appliance is installed, fully remove the ‒...
Page 20
en Installation instructions Establishing the exhaust air connection (exhaust pipe, 120 mm diameter) Secure the reducing connector to the air-pipe con- nector. Secure the exhaust pipe to the air pipe connector. Establish the connection to the exhaust air opening. Seal the joints. Installing the flue duct WARNING ‒ Risk of injury! Components inside the appliance may have sharp...
Page 24
Valid within Great Britain: Imported to Great Britain by BSH Home Appliances Ltd. Grand Union House Old Wolverton Road Wolverton, Milton Keynes MK12 5PT United Kingdom Manufactured by BSH Hausgeräte GmbH under the trademark licence of Siemens AG *9001618242* 9001618242 (020407) ...