Keep hands clear of cutter when motor is running to
prevent personal injury.
Never touch the cutter immediately after use. It may be
extremely hot.
Provide clearance under workpiece for router cutter
when through-cutting.
Tighten collet nut securely to prevent the cutter
from slipping.
Never tighten collet nut without a cutter.
Do not use router cutters with a diameter in excess of
30 mm in this tool.
Avoid Climb-Cutting (cutting in direction opposite that
shown in Fig. L). Climb-Cutting increases the chance
for loss of control resulting in possible injury. When
"Climb-Cutting" is required (backing around a corner), exercise
extreme caution to maintain control of router. Make smaller
cuts and remove minimal material with each pass.
Always use straight-cutters, rabbet-cutters, profile cutters,
slotter cutters or grooved knives with a shank diameter of
6–8 mm which corresponds to the size of the collet in your tool.
Always use cutters suitable for a speed of min. 30000 min
marked accordingly.

WARNING: Never use cutters with a diameter exceeding
the maximum diameter indicated in the technical data.

WARNING: We recommend the use of a residual current
device with a residual current rating of 30mA or less.
Residual Risks
In spite of the application of the relevant safety regulations
and the implementation of safety devices, certain residual risks
cannot be avoided. These are:
Impairment of hearing.
Risk of personal injury due to flying particles.
Risk of burns due to accessories becoming hot
during operation.
Risk of personal injury due to prolonged use.
Electrical Safety
The electric motor has been designed for one voltage only.
Always check that the power supply corresponds to the voltage
on the rating plate.
Your D
WALT tool is double insulated in accordance
e
with EN62841; therefore no earth wire is required.

WARNING: 115 V units have to be operated via a fail-safe
isolating transformer with an earth screen between the
primary and secondary winding.
If the supply cord is damaged, it must be replaced only by
D
WALT or an authorised service organisation.
e
Mains Plug Replacement
(U.K. & Ireland Only)
If a new mains plug needs to be fitted:
Safely dispose of the old plug.
Connect the brown lead to the live terminal in the plug.
Connect the blue lead to the neutral terminal.

WARNING: No connection is to be made to the
earth terminal.
Follow the fitting instructions supplied with good quality plugs.
Recommended fuse: 13 A.
Using an Extension Cable
If an extension cable is required, use an approved 3–core
extension cable suitable for the power input of this tool (see
Technical Data). The minimum conductor size is 1.5 mm
maximum length is 30 m.
When using a cable reel, always unwind the cable completely.
Package Contents
D26200
The package contains:
1 Router with fixed base
1 Fixed base dust collection
1 Basic parallel fence (D262003)
1 Collet 8 mm (GB: 1/4")
1 Wrench
and
-1
1 Instruction manual
D26203
The package contains:
1 Router with plunge base
1 Plunge base dust collection
1 Parallel fence with guide rods
1 Collet 8 mm (GB: 1/4")
1 Wrench
1 Guide bush 17 mm
1 Centering cone
1 Instruction manual
D26204
The package contains:
1 Router with plunge base
1 Fixed base
1 Dust collection fixed base
1 Dust collection plunge base
1 Parallel fence with guide rods
1 Basic parallel fence (D262003)
1 Collet 8 mm (GB: 1/4")
1 Wrench
1 Guide bush 17 mm
1 Centering cone
1 Instruction manual
Check for damage to the tool, parts or accessories which may
have occurred during transport.
Take the time to thoroughly read and understand this manual
prior to operation.
EnGLIsH
2
; the
31

Advertisement

loading

This manual is also suitable for:

D26200D26204D26204k