Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND
CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
F WARNING! Ensure health & safety, local authority, and general workshop practice regulations are adhered to when using this equipment.
F
WARNING! Disconnect the washer from the air supply before changing accessories, servicing or performing any maintenance.
p
Maintain the washer in good condition (use an authorised service agent).
Replace or repair damaged parts. Use genuine parts only. Non authorised parts may be dangerous and will invalidate the warranty.
Locate the washer in an adequate working area for its function, Ensure the washer is stood on a firm level surface. Keep area clean
and tidy and free from unrelated materials. Ensure the area is well ventilated and has adequate lighting.
F WARNING! Installation site must be equipped with suitable fire extinguishers (water must not be used) and escape routes.
F
WARNING! Ensure correct air pressure is maintained and not exceeded. Recommended pressure 75-100psi.
p
Keep air hose away from heat, oil and sharp edges. Check air hose for wear before each use, and ensure that all connections are secure.
Use only recommended solvents as a cleaning agent, do not pour any other type of cleaning fluid into the tank.
Keep the washer clean. Remove and clean the filter regularly for best and safest performance.
Keep sources of ignition, such as heaters, lamps, etc away from the unit, together with flammable or combustible materials.
F
WARNING! Wear approved safety eye protection, mask and gloves. If fluid gets on skin or in eyes wash thoroughly with water
p
and take any other action as required by the solvent instructions.
Remove ill fitting clothing. ties, watches, rings, and other loose jewellery, and contain long hair, and wear appropriate protective clothing.
Maintain correct balance and footing. Ensure the floor is not slippery and wear non slip shoes.
Keep non essential persons away from the working area.
In case of fire in parts unit, do not attempt to remove parts, or the washer.
F
WARNING! DO NOT smoke whilst handling gunwash or solvents - risk of explosion.
p
DO NOT use the cleaner without the fume extraction flue attached, and ensure the flue removes the fumes appropriately.
DO NOT use the washer for any purpose other than for which it is designed.
DO NOT operate the washer if any parts are missing or damaged as this may cause failure or possible personal injury.
DO NOT over fill the washer, and DO NOT use the washer without the cloth filter in base of unit.
DO NOT direct air from the air hose at yourself or others.
DO NOT operate the washer when you are tired, under the influence of alcohol, drugs or intoxicating medication.
When cleaning is complete, ensure all controls are in the ‘off’ position and that the air supply is turned off.
F
WARNING! It is the user’s responsibility to ensure that there is no uncontrolled discharge of any fluids used with this unit and that
p
appropriate arrangements have been made for correct disposal of waste fluids in accordance with government and local authority regulations.
2. INTRODUCTION & SPECIFICATIONS
The SM2399 is a compact unit suitable for small body shop use. The tank is robustly manufactured, and features an air extraction, stainless steel
wash tank with brass distribution bars. A self reciprocating pump delivers up to 12 ltrs / min with an air input pressure of 75-100psi and consumes
approx 4/7cfm. This ensures a high volume of solvent is delivered through the spray jet nozzles and optimise the cleaning performance. The unit
is suitable for cleaning gravity, suction and HVLP guns.
SPECIFICATIONS
Operating pressure . . . . . . . . . . . . . . . . . . . . .75-90psi
Air Consumption . . . . . . . . . . . . . . . . . . . . . . . .4/7cfm
Cleans . . . . . . . . . . . . . . . . . . . . . . . . .2 pots + 2 guns
Width/Depth/height (mm) . . . . . . . . . . . .440x475x1020
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28kg
3.
AIR SUPPLY
3.1.
Ensure the air valve is in the "off" position before connecting to the air supply.
3.2.
You will require an air pressure of more than 75psi, and an air volume of more than 4 cfm for operating the unit.
3.3.
F
WARNING! Ensure the air supply does not exceed 100PSI. Too high an air pressure and unclean air will shorten the product
p
life due to excessive wear, and may be dangerous causing possible damage and personal injury.
3.4.
Drain the air supply tank daily. Water in the air line will damage the item being supplied.
3.5.
Clean the air inlet filter screen weekly. For recommended
hook-up, see diagram to right.
3.6.
Line pressure should be increased to compensate for
unusually long air hoses (over 8 metres). The minimum
hose diameter should be 10mm I.D. and fittings must
have the same inside dimensions.
3.7.
Keep hose away from heat, oil and sharp edges.
Check hoses for wear, and make certain that
all connections are secure.
3.8.
The cleaner’s input connection is 1/4” BSP.
p
p
p
p
p
p
INSTRUCTIONS FOR:
SPRAY GUN CLEANING TANK
SM2399
Model:
HOOK UP
SM2399 - 0000 - (1) - 160799

Advertisement

loading

Summary of Contents for Sealey SM2399

  • Page 1 2. INTRODUCTION & SPECIFICATIONS The SM2399 is a compact unit suitable for small body shop use. The tank is robustly manufactured, and features an air extraction, stainless steel wash tank with brass distribution bars. A self reciprocating pump delivers up to 12 ltrs / min with an air input pressure of 75-100psi and consumes approx 4/7cfm.
  • Page 2 (fig 1.2). Ensure the first 1m of flue is vertical and thereafter the flue may curve to the designated ventilation outlet which should remove fumes to the outside of the building. A range of adaptors are available from your Sealey dealer (fig 3). 4.2. CONNECTING THE SOLVENT SUPPLY.
  • Page 3 6.2.2. Keep pick-up filter clean by rinsing in solvent and blowing out with an air line. 6.2.3. Change the green base filter (Model no SM2399/15) every three months, or more frequent if heavy use. 6.2.4. Regularly check to ensure there are no obstructions to the extraction flue.