Sharp CD-BK260V Service Manual page 55

Video cd mini system
Hide thumbs Also See for CD-BK260V:
Table of Contents

Advertisement

IC701 RH-iX0411AWZZ: System Microcomputer (IX0411AW) (1/2)
Pin No.
Port Name
Terminal Name
1
VDD
VDD
2
P37
-20 dB ATT
3
P36
NO USE
DSA_STB
4
P35
T_BIAS
5
P34
T_T1/T2
6
P33
REC/PLAY
7
P32
RES OUT
8
P31
DRF
9
P30
WRQ
10
RESET
RESET
11
X2
X2
12
X1
X1
13
VPP/IC
XVPP/IC
14*
XT2
XT2
15
P04
SPN
16
VDD
VDD
17
P27
CD CLK
18
P26
CD DI
19
P25
CD DO
20
P24
CD CE
21
P23
CE
22
P22
CLK
23
P21
DI
24
P20
DO
25
AVSS
AVSS
26
ANI7
O/C SW
DISC NO SW
P17
DSA_DATA
27
ANI6
NO USE
TUNER SM
P16
DSA_ACK
28
ANI5
SPEANA 2
29
ANI4
SPEANA 1
30
ANI3
SPEANA 0
31-33
ANI2-ANI0
KEY 2-KEY 0
34
AVDD
AVDD
35
AVREF
AVREF
36
INTP3
P_IN
37
P02
JOG 1
38
P01
JOG 0
39
INTP0
REMOCON
40
VSS
VSS
41
P74
SMUTE
42
P73
T_SOL_B
43
P72
T_SOL_A
44
P71
T_MOTOR
45
P70
TIMER LED
46
VDD
VDD
47*
P127
AC RLY_CONT
48
P126
SP_RLY
49
P125
SP_DET
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.
All manuals and user guides at all-guides.com
Input/Output
Input
(+) POWER SUPPLY.
Output
-20 dB ATTENUATOR.
Output
GND
Input/Output
DSA STROBE.
Output
TAPE RECORD BIAS.
Output
TAPE T1/T2 CHANGE.
Output
TAPE REC/PLAY CHANGE.
Output
CD DSP RESET & MPEG MICROCOMPUTER RESET.
Input
CD RF LEVEL DETECTION.
Input
CD DSP WRITE REQUEST.
Input
RESET.
Output
MAIN CLOCK.
Input
MAIN CLOCK.
GND
OPEN
Input
TUNER SPAN CHANGE.
Input
(+) POWER SUPPLY.
Output
CD DSP CLOCK.
Output
CD DSP COMMAND.
Input
CD DSP CODE Q OUT.
Output
CD DSP CE OUTPUT.
Output
CE OUTPUT.
Output
CLOCK OUTPUT.
Output
DATA OUTPUT.
Input
DATA INPUT.
ANALOG GROUND.
Input
CD OPEN/CLOSE SWITCH.
Input
CD DISC NUMBER SWITCH.
Input/Output
DSA DATA INPUT.
Input
GND
Input
TUNER SIGNAL METER INPUT.
Input/Output
DSA ACKNOWLEDGE.
Input
SPEANA DATA INPUT 16 kHz.
Input
SPEANA DATA INPUT 1 kHz.
Input
SPEANA DATA INPUT 63 kHz.
Input
KEY INPUT.
Input
ANALOG VDD.
ANALOG REF VOLTAGE.
Input
POWER FAILURE DETECT.
Input
JOG VOLUME INPUT 1.
Input
JOG VOLUME INPUT 0.
Input
REMOCON INPUT.
GROUND VOLTAGE.
Output
SYSTEM MUTE CONTROL.
Output
TAPE 2 SOLENOID CONTROL.
Output
TAPE 1 SOLENOID CONTROL.
Output
TAPE MOTOR CONTROL.
Output
TIMER LED CONTROL.
Input
(+) POWER SUPPLY.
Output
AC RELAY CONTROL.
Output
SPEAKER OUTPUT RELAY CONTROL.
Input
SPEAKER OUTPUT DETECTION.
– 55 –