Electrically ground the unit according to local codes or,
in the absence of local codes, according to the current
National Electric Code (ANSI/NFPA No. 70). A green
ground wire is provided in the field make-up box.
NOTE: This furnace contains electronic components that
are polarity sensitive. Make sure that the furnace is wired
correctly and is properly grounded.
Accessory Terminals
One line voltage "EAC" 1/4" spade terminal is provided
on the furnace integrated control. See Figure 24 or Figure
25 for integrated control configuration. This terminal
is energized when the indoor blower is operating. Any
accessory rated up to one amp can be connected to this
terminal with the neutral leg of the circuit being connected
to one of the provided neutral terminals. If an accessory
rated at greater than one amp is connected to this terminal,
it is necessary to use an external relay.
One line voltage "HUM" 1/4" spade terminal is provided
on the furnace integrated control. See Figure 24 or Figure
25 for integrated control configuration. This terminal is
energized in the heating mode when the combustion air
inducer is operating. Any humidifier rated up to one amp
can be connected to this terminal with the neutral leg of
the circuit being connected to one of the provided neutral
terminals. If a humidifier rated at greater than one amp
is connected to this terminal, it is necessary to use an
external relay.
Generator Use - Voltage Requirements
The following requirements must be kept in mind when
specifying a generator for use with this equipment:
The furnace requires 120 volts ± 10% (Range: 108
volts to 132 volts).
The furnace operates at 60 Hz ± 5% (Range: 57 Hz
to 63 Hz).
The furnace integrated control requires both polarity
and proper ground. Both polarity and proper grounding
should be checked before attempting to operate the
furnace on either permanent or temporary power.
Generator should have a wave form distortion of less
than 5% RHO.
Page 20 of 38
Thermostat
Install the room thermostat according to the instructions
provided with the thermostat. See Table 9 for thermostat
designations. If the furnace is being matched with a
heat pump, refer to the FM21 installation instruction or
appropriate dual fuel thermostat instructions.
Indoor Blower Speeds
1.
When the thermostat is set to "FAN ON," the indoor
blower will run continuously on the low speed when
there is no cooling or heating demand. See Table 18
for allowable circulation speeds.
2.
When the unit is operating in the high-fire or low-
fire heating mode, the indoor blower will run on the
corresponding heating speed.
3.
When the unit is operating in the low cool or the high
cool cooling mode, the indoor blower will run on the
corresponding cooling speed.
Issue 2220