Initialization
(1) The wired controller will display all the icons after be 
powered on or reset, then it gets into the initializing process.
The controller will display in sequence as follows :
(the top-left corner) → 
  → 
 (the bottom-right corner) 
→ 
 (the top-left corner), the green LED (ON/OFF key) 
flashes all the time until the initialization ends.
(2) If the wired controller can't communicate with the indoor 
unit PCB normally after powering on, the initialization will be
finished in 4 minutes, and then the communication malfunction 
can be checked from the malfunction inquiry function.
Backlight time
(1) In the state of off , when the backlight is lit up, long press 
TIME and
keys for 5 seconds to set backlight time, the
parameter value is displayed in the upper left corner. Press
or
 key to switch parameter between 00(means backlight 
always on)/15S/30S/60S and confirm by pressing the key 
MENU.
(2) The backlight time is fixed for 15 seconds when the 
controller is turned off.