Fault description
Measured value
fluctuates around
10 ... 20 %
0
time
Reaction after fault recti-
fication

Exchanging the rod

60
Cause
Various echoes from an uneven product
surface, e.g. an extraction funnel
Reflections from the product surface via the
vessel wall (deflection)
Depending on the reason for the fault and the measures taken, the
steps described in chapter "Setup" must be carried out again or must
be checked for plausibility and completeness.
9.5

Exchanging the electronics module

If the electronics module is defective, it can be replaced by the user.
In Ex applications, only instruments and electronics modules with ap-
propriate Ex approval may be used.
If there is no electronics module available on site, the electronics
module can be ordered through the agency serving you. The electron-
ics modules are adapted to the respective sensor and differ in signal
output or voltage supply.
The new electronics module must be loaded with the default settings
of the sensor. These are the options:
In the factory
Or on site by the user
In both cases, the serial number of the sensor is needed. The serial
numbers are stated on the type label of the instrument, on the inside
of the housing as well as on the delivery note.
When loading on site, the order data must first be downloaded from
the Internet (see operating instructions "Electronics module").
Caution:
All application-specific settings must be entered again. That's why you
have to carry out a fresh setup after exchanging the electronics.
If you saved the parameter settings during the first setup of the sen-
sor, you can transfer them to the replacement electronics module. A
fresh setup is then not necessary.
9.6
Exchanging the rod
The rod (meas. part) of the probe can be exchanged, if necessary. To
loosen the meas. rod you need a fork spanner with spanner width 10.
Caution:
Remember that the polished rod of the food version is very sensitive
to damage and scratching. Use special tools in order to avoid damag-
ing the surface.
1. Loosen the rod by applying a fork spanner to the flat surfaces
(SW 10), provide counterforce manually on the process fitting
SITRANS LG240 - Operating Instructions
Rectification
Check parameter "Material Type" and
adapt, if necessary
Optimize installation position and sensor
orientation