Download Print this page

NEC SCP100 Installation And Assembly page 2

Lightweight adjustable suspended ceiling plate for projector mounts

Advertisement

IMPORTANT PRE-ASSEMBLY
INFORMATION:
Ceiling Tray (A) is designed to fit above a
24" (610 mm) x 24" (610 mm) section of a
conventional suspended ceiling system. It
may also be mounted above 24" x 48"
conventional suspended ceiling. Ceiling
runners (see DETAIL 2, page 3) should
have a "T" cross section and a minimum
height of 1.5" (38 mm).
For certain installations it may be best to
install ceiling anchors (step 5) before
installing the ceiling tray (step 1).
For Flush Mounting Applications
From the top down, thread flush mount tube (J)
down through retaining collar in adjustable
collar mount plate.
Skip to step 4.
J
A
Snap escutcheon ring (M) around flush mount tube
or extension column and slide up until flush with
ceiling tile. Hook turnbuckles (F) into ceiling tray
(A) as shown in figure 2. Hook turnbuckles
through ceiling tray (A) where indicated by black
rectangles in illustration below.
A
TOP VIEW - CEILING TRAY
Black rectangles show correct
positions for Turnbuckles.
Visit the Peerless Web Site at www.peerlessindustries.com
Place ceiling tray (A) in grid above 24" x 24" or 24" x 48" false ceiling
tile so that lip of ceiling tray (A) rests on ceiling runners as shown in
figure 1. Place in desired position and tighten knurled knobs until
ceiling tray (A) is securely attached to ceiling runners.
Slide collar mount plate to desired position. Using hole in collar mount
plate, mark false ceiling tile where hole will be cut. Slide collar mount
plate out of the way. Cut out 2.25" hole in false ceiling tile. Slide collar
mount plate back into position and tighten all carriage bolts and
nylock nuts using a 7/16" wrench.
COLLAR MOUNT
PLATE
A
NYLOCK NUT
figure 1
For Extension Column Applications
From the bottom up, thread extension column
(not included) up through retaining collar in
adjustable collar mount plate. Align notch in
extension column with hole in collar and fasten
using M5 x 10 mm security screw (K) as shown
in detail 1.
A
F
figure 2
2 of 3
For customer service call 1-800-729-0307 or 708-865-8870.
CARRIAGE
KNURLED
BOLT
KNOB
CEILING
RUNNER
ISSUED: 12-16-04 SHEET #: 120-9015-1
K
DETAIL 1

Advertisement

loading