Before attempting to connect or install this product,
please read these instructions carefully and save this manual for future use.
Caution
Hold this board only by its edges. Otherwise components on the board may be damaged by static electricity.
Preface
The WJ-PB85A32 Alarm Input Board is an optional board for expanding the capabilities of the
System 850 Matrix Switcher.
It transmits a received alarm signal to the CPU (Central Processing Unit) via Ethernet to activate
the assigned alarm event.
The board an also be used an as alarm output board by changing the position of internal switch-
es.
Appearance
q Alarm Input Port (1 - 32)
This port accepts alarm input from the associated alarm sensors through either Normally
Open (N.O) or Normally Closed (N.C) contacts.
Pin No.
37
36
35
34
19
37
33
18
36
17
35
32
16
34
15
31
33
14
32
13
30
31
12
30
11
29
29
10
28
28
9
27
8
26
27
7
25
6
24
26
5
23
4
25
22
3
21
2
24
20
1
23
22
21
20
Designation
Pin No.
Ground
19
Ground
18
Not used
17
Not used
16
Not used
15
Alarm 32
14
Alarm 31
13
Alarm 30
12
Alarm 29
11
Alarm 28
10
Alarm 27
Alarm 26
Alarm 25
Alarm 24
Alarm 23
Alarm 22
Alarm 21
Alarm 20
-1-
Extend Card (Alarm in)
WJ-PB85A32
Model No.
Designation
Alarm 19
Alarm 18
Alarm 17
Alarm 16
Alarm 15
Alarm 14
Alarm 13
Alarm 12
Alarm 11
Alarm 10
9
Alarm 9
8
Alarm 8
7
Alarm 7
6
Alarm 6
5
Alarm 5
4
Alarm 4
3
Alarm 3
2
Alarm 2
1
Alarm 1
ALARM
IN
1-32
q

Advertisement

loading

Summary of Contents for Panasonic WJ-PB85A32

  • Page 1 Hold this board only by its edges. Otherwise components on the board may be damaged by static electricity. Preface The WJ-PB85A32 Alarm Input Board is an optional board for expanding the capabilities of the System 850 Matrix Switcher. It transmits a received alarm signal to the CPU (Central Processing Unit) via Ethernet to activate the assigned alarm event.
  • Page 2 Board Setting Before installing this board, the following settings should be made by qualified service personnel or system installers. Reset Switch ALARM INPUT BOARD 1. Set switches (SW1 and SW2) on the board to designate the Alarm Input board number as shown in the following table. The factory default setting is Board Number 1 (00).
  • Page 3 2. Set switches (SW4, SW5, SW6, and SW7) on the Installation board to meet the alarm input requirements. The following installation should be made by qualified Normally Closed (N.C) service personnel or system installers. OFF: Normally Open (N.O) The factory default settings are OFF. Installing Additional Extension Boards 1.
  • Page 4 5770 Ambler Drive, Mississauga, A Division of Matsushita Electric Corporation of America Ontario, L4W 2T3 Canada (905)624-5010 Executive Office: One Panasonic Way 3E-7, Secaucus, New Jersey 07094 Panasonic Sales Company Regional Offices: Division of Matsushita Electric of Puerto Rico Inc.