8. CONTROL PANEL (FIG.21)

A: main switch
E (SP2 only): mixing spiral rotation activation
switch (E1 left spiral, E2 right spiral)
B: refrigerator system management switch (B1
left side, B2 right side)
Snowflake: freeze hybrid mode
0: washing
Drops: night mode (defrost)
C (LIGHT version only): light switch (C1 left
side, C2 right side)
D (ULTRA version only): light switch (D1 left
side, D2 right side)
Position I: Normal light mode,
sanitization mode not active
Position 0: lights off
Position II: ULTRA sanitization mode,
near UVA LED and normal LED in
operation
WARNING
AVOID DIRECT AND CONTINUOUS (FOR
MORE THAN 1 MINUTE) OBSERVATION AT
SHORT DISTANCE (LESS THAN 60 CM) OF
LIGHT SOURCES.
Emission date: July, 2021
Note -----------------------------------------------
The SP ULTRA model machines are
equipped with an effective nUVA LED
lighting system that guarantees a 99%
bactericidal effect in 4 hours.
------------------------------------------------------
Revision: 2
Fig. 21