LCD Display (factory setting)
DIAG 0
HOURS METER
0X
XXXX
1. DRUM RUNNING
2. TAPE RUNNING
3. OPERATION
4. THREADING
5. DRUM RUN-2
6. TAPE RUN-2
7. OPERATION-2
8. THREADING-2
DIAG 1
TIME
1 XXXXXX
1
2
3
DIAG 2
DATE
2 XXXXXX
1
2
3
DIAG 3
BATTERY VOLTAGE
BEFORE END
3
11. 3
DIAG 4
BATTERY VOLTAGE
END
4
11. 0
DIAG 5
VITC INSERT LINE
5
1618
DNV-5
Description
The contents below are displayed. (For more details, refer to 6-3-1, "Hours Meter".)
........... Total drum rotating hours
........... Total tape running hours
........... Total power-on time
........... Total number of threading
........... Drum rotating hour (Customer-resetable)
........... Tape running hour (Customer-resetable)
........... Power-on time (Customer-resetable)
........... The number of threading (Customer-resetable)
Internal timer setting.
1. Sets the hour.
2. Sets the minute.
3. Sets the second.
Internal timer date setting.
1. Sets the month (for NTSC) /day (for PAL).
2. Sets the day (for NTSC) /month (for PAL).
3. Sets the year.
Displays and sets the battery before end voltage.
(For the setting, refer to the Operation Manual.)
Battery before end voltage setting
11.0 to 13.0 V (in units of 0.1 V)
"0" is displayed on the LCD when the setting is OK.
"E" is displayed on the LCD when the setting is NG.
Displays and sets the battery end voltage. (For the setting, refer to the Operation Manual.)
Battery end voltage setting
10.5 to 11.5 V (in units of 0.1 V)
"0" is displayed on the LCD when the setting is OK.
"E" is displayed on the LCD when the setting is NG.
Displays and sets the VITC insertion line.
12 to 19 lines (For NTSC)
9 to 22 lines (For PAL)
NEXT LINE
FIRST LINE
3-1. DIAG Memu