  • Page 1 SIMATIC Industrial PC SIMATIC Panel PC 677 Operating Instructions Edition 07/2006 Industrial PC Panel PC 677 simatic DOCUMENTATION DOCUMENTATION...
  • Page 3 Foreword Safety information Description SIMATIC Application planning Industrial PC Installation SIMATIC Panel PC 677 Connecting Integration into an Operating instructions automation system Commissioning Operation and Configuration Operating Functions Maintenance and service Alarm, error and system messages Troubleshooting/FAQs Technical data Dimensional drawings Detailed descriptions Appendix ESD directives...
  • Page 4 Trademarks All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
  • Page 5 Table of contents Foreword ..............................1-1 Overview ............................ 1-1 Safety information........................... 2-1 Safety information ........................2-1 General information ........................2-4 Description.............................. 3-1 Design ............................3-1 Technical features........................3-3 Accessories..........................3-5 Application planning..........................4-1 Overview ............................ 4-1 Unpacking and checking the delivery ..................4-2 Device identification data ......................
  • Page 6 Table of contents Integration into an automation system ....................7-1 Overview ............................ 7-1 Device in a SIMATIC S7 configuration..................7-2 7.2.1 MPI/PROFIBUS-DP network...................... 7-2 7.2.2 Connecting an S7 automation system ..................7-3 Networking via Industrial Ethernet ..................... 7-4 Commissioning ............................8-1 Overview ............................
  • Page 7 Table of contents Functions .............................. 11-1 11.1 Overview ..........................11-1 11.2 Safecard on Motherboard (SOM)..................... 11-2 11.3 Temperature monitoring......................11-4 11.4 Watchdog (WD)........................11-5 11.5 Fan monitoring ......................... 11-6 Maintenance and service........................12-1 12.1 Servicing ..........................12-1 12.2 Maintenance and care of devices with stainless steel front............. 12-3 12.3 Chemical resistance of stainless steel fronts................
  • Page 8 Table of contents Alarm, error and system messages ...................... 13-1 13.1 Boot error messages........................ 13-1 13.2 Introduction to the BIOS beep codes ..................13-3 13.3 BIOS beep codes ........................13-5 Troubleshooting/FAQs.......................... 14-1 14.1 General problems........................14-1 14.2 Problems when using modules of third-party manufacturers........... 14-2 14.3 Temperature limits ........................
  • Page 9 Table of contents 17.7 BIOS Setup ..........................17-39 17.7.1 Overview ..........................17-39 17.7.2 Starting BIOS Setup....................... 17-40 17.7.3 BIOS setup menus......................... 17-41 17.7.4 Main menu ..........................17-43 17.7.5 Advanced menu ........................17-55 17.7.6 Security menu ........................17-61 17.7.7 Boot menu..........................17-62 17.7.8 Version menu .........................
  • Page 10 Table of contents SIMATIC Panel PC 677 viii Operating instructions, Release 07/2006, A5E00877769-01...
  • Page 11 Foreword Overview Purpose of this manual These operating instructions contain all the information you need for commissioning and using the SIMATIC Panel PC 677. It is intended both for programming and testing personnel who commission the device and connect it with other units (automation systems, programming devices), as well as for service and maintenance personnel who install add-ons or carry out fault/error analyses.
  • Page 12 Trademarks All names labeled with ® symbol are registered trademarks of Siemens AG. Other names used in this documentation may be trademarks, the use of which by third parties for their own purposes could violate the rights of the owner.
  • Page 13 Safety information Safety information Warning Emergencies In the event of a device fault, interrupt the power supply immediately. Inform the customer service personnel responsible. Malfunctions can occur when the operator controls or power cable are damaged or when liquids or foreign objects penetrate the device. Warning Following the results of a risk analysis, additional protection equipment on the machine or the system is necessary to avoid endangering persons.
  • Page 14 Safety information 2.1 Safety information Electrical connection Warning Disconnect the device from the mains before every intervention. Do not touch power lines or data transmission lines during electrical storms and do not connect any cables. System expansions Only install system expansion devices designed for this device. If you install other expansions, you may damage the system or violate the safety requirements and regulations for radio frequency interference suppression.
  • Page 15 Safety information 2.1 Safety information Handling and disposal of lithium batteries Warning Danger of explosion and the release of harmful substances! Do not throw lithium batteries into fire, do not solder onto the cell body, do not open, do not short circuit, do not reverse pole, do not heat above 100 °C, dispose of according to regulations, and protect from direct sunlight, moisture and condensation.
  • Page 16 Safety information 2.2 General information General information Overview Caution The device is approved for operation in closed rooms only. The guarantee is void if this stipulation is ignored. Avoid extreme environmental operating conditions. Protect your device against dust, moisture and heat. For additional information, refer to the Technical data. Do not place the device in direct sunlight.
  • Page 17 Tools & downloads Please check regularly if updates and hotfixes are available for download to your device. Downloads are available on the Internet at http://www.siemens.com/asis under "Support". Click on "Software Tools & Downloads" on "Overview Panel PCs" Using the global search function, you can then also search for any downloads you require.
  • Page 18 Safety information 2.2 General information Sources of light Notice Position the screen so that it is not subject to direct sunlight or other strong sources of light. Defective pixels in the display At present, the manufacturing process of modern displays does not guarantee that all pixels of the display will be perfect.
  • Page 19 Description Design Design Figure 3-1 Panel PC 677 Computer unit Control unit Brief description The device is available with different control units which are distinguished by the size of the display and by the membrane keyboard or touch screen. SIMATIC Panel PC 677 Operating instructions, Release 07/2006, A5E00877769-01...
  • Page 20 Description 3.1 Design Keyboard variants • Color display with backlighting: – 12'' TFT technology with 800 x 600 resolution – 15'' TFT technology with 1024 x 768 resolution • Membrane keyboard with alphanumeric keys, numeric keys, cursor keys and control keys •...
  • Page 21 Description 3.2 Technical features Technical features General features Installation design Panel-mounting device Graphic Part of the graphic memory is dynamically occupied in the system memory VGA: 1600 x 1200 pixels, 85 Hz, 32-bit colors • DVI-I: 1600 x 1200 pixels, 60 Hz, 32-bit colors •...
  • Page 22 Description 3.2 Technical features Configuration options 100 - 240 V AC, autorange Power supply • DC 24 V, optional • Both with bridging for short-time voltage failures as per NAMUR: maximum of 20 ms at 0.85 x V = rated voltage) rated rated Intel ®...