Installation Diagram Of Indoor And Outdoor Units; Optional Installation Parts - Toshiba RAS-18N3KV2 Series Installation Manual

Hide thumbs Also See for RAS-18N3KV2 Series:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS

INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
5
8
(
Flat head
Battery cover
wood screw
&
Flat head
wood screw
3
Batteries
The provided Remote Controller is a
wireless type, which also can be used as
a wire.
Please see "How to Connect The Remote
Controller for Wired Operation", in case of
wired control is required.
When installing the outdoor unit, leave open
in at least two of direction (A), (B), (C) and
(D) shown in the fi gure on the right.
Remark :
• Detail of accessory and installation parts can see in the
accessory sheet.
• Some pictures might be different from the actual parts.

Optional Installation Parts

Part
Parts name
code
Refrigerant piping
A
Liquid side
: dia. 6.35 mm
Gas side
: dia. 12.70 mm
Pipe insulating material
B
(polyethylene foam, 8 mm thick)
C
Putty, PVC tapes
Filter
6
Filter
8
Flat head
4
wood screw
Vinyl tape
Apply after carrying
out a drainage test.
2
Wireless remote control
(C)
(B)
Q'ty
One
each
1
One
each
1
Installation
Hook
plate
Shield pipe
Remote control holder
(D)
Saddle
Extension drain hose
(Not available,
provided by installer)
(A)
Fixing bolt arrangement of outdoor unit
• Secure the outdoor unit with fi xing bolts and nuts if the unit is likely to be
exposed to a strong wind.
• Use dia. 8 mm or dia. 10 mm anchor bolts and nuts.
• If it is necessary to drain the defrost water, attach drain nipple 9 and cap
water proof ! to the bottom plate of the outdoor unit before installing it.
108 mm
28 mm
Air outlet
600 mm
w
When using a multi-system outdoor unit is used, refer to the installation
manual provided with the model concerned.
3
For the rear left and left piping
Wall
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain hose sloped
downward.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Bottom
Rear
right
left
Bottom left
Insulate the refrigerant pipes separately
with insulation, not together.
8 mm thick heat resisting
polyethylene foam
125 mm
Air inlet
* Drain nipple and cap
water proof are packed
in outdoor unit.
90 mm
Drain outlet
EN
EN
ES
FR
IT
DE
PT
PL
CZ
RU
CR
Left
HU
TR
NL
GR
SV
FI
NO
DK
RO
BG
EE
LV
SK
SI

Advertisement

Chapters

Table of Contents
loading

Table of Contents