Panasonic PT-D4000 Specifications

Rs-232c control
Hide thumbs Also See for PT-D4000:

Advertisement

Panasonic Projector RS-232C Control Specifications
P T- D W 5 1 0 0 / D 5 7 0 0 / D 4 0 0 0

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic PT-D4000

  • Page 1 Panasonic Projector RS-232C Control Specifications P T- D W 5 1 0 0 / D 5 7 0 0 / D 4 0 0 0...
  • Page 2 Using the Serial Terminals 1. Basic Format Transmission from the computer begins with STX, then the ID, command, parameter, and ETX are sent in this order. Add parameters according to the details of control. Basic control command (without parameter) Start (STX) 1 byte 4 bytes...
  • Page 3 ID of the basic control command 4 bytes String ADZZ ID23 AD01 ID24 AD02 ID25 AD03 ID26 AD04 ID27 AD05 ID28 AD06 ID29 AD07 ID30 AD08 ID31 AD09 ID32 ID10 AD10 ID33 ID11 AD11 ID34 ID12 AD12 ID35 ID13 AD13 ID36 ID14 AD14...
  • Page 4 VPS SYSTEM in RS232C settings of this projector is MASTER and the sent ID is ALL, or If Group (A Z) of the sent ID coincides with GROUP in RS232C settings of this projector and GROUP in RS232C settings of this projector is MASTER.
  • Page 5: Auto Setup

    2. Basic Control Command Explanatory notes Yes: Enable No: Disable 2.1. Power ON (Lamp ON) Hexadecimal Character Response (Callback) In the period when the command can be accepted (This command in power-on condition is included) Hexadecimal Character Acceptability SECURITY STNDBY Note: •...
  • Page 6: Test Pattern

    2.5. SHUTTER Hexadecimal Character Parameters (*1, *2) Shutter OFF Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY Note: • REMOTE2 is given to priority. Calls back ER402 when the parameter is different from the setting of REMOTE2. 2.6.
  • Page 7 2.8. ON SCREEN Hexadecimal Character Parameters (*1, *2) Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY 2.9. MENU key Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character 2.10.
  • Page 8: Lamp Select

    2.16. FUNC1 key Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character 2.17. SYSTEM SEL key Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character 2.18. ASPECT key Hexadecimal Character Response (Callback)
  • Page 9: Lamp Power

    2.22. LAMP POWER Hexadecimal Character Parameters (*1, *2) Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY 2.23. SUB MEMORY CHANGE Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4) Sets 00 when the sub memory is not used. Not used Hexadecimal Character...
  • Page 10: Picture Mode

    2.25. SUB MEMORY DELETE Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4) Hexadecimal Character Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY 2.26. PICTURE MODE Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4, *5, *6) DYNAMIC Hexadecimal...
  • Page 11: Color Temp

    2.28. TINT Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY 2.29. COLOR TEMP. Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4) DEFAULT Hexadecimal...
  • Page 12 2.31. W-BAL LOW G Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY 2.32. W-BAL LOW B Hexadecimal Character Hexadecimal Character...
  • Page 13 2.34. W-BAL HIGH G Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY 2.35. W-BAL HIGH B Hexadecimal Character Hexadecimal Character...
  • Page 14: White Gain

    2.37. BRIGHT Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY 2.38. WHITE GAIN Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4) Hexadecimal Character...
  • Page 15 2.40. SHARPNESS Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY 2.41. NR Hexadecimal Character Hexadecimal Character Parameters (*1, *2) Hexadecimal Character Response (Callback)
  • Page 16 2.43. TV-SYSTEM Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character NTSC4.43 Hexadecimal Character Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY 2.44. POSITION H Hexadecimal Character Hexadecimal Character...
  • Page 17 2.46. ASPECT Hexadecimal Character Hexadecimal Character Parameters (*1, *2) AUTO Hexadecimal Character H FIT Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY 2.47. ZOOM H Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character Hexadecimal...
  • Page 18: Clock Phase

    2.49. CLOCK PHASE Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY VIDEO S-VIDEO 2.50. TOTAL DOTS Hexadecimal Character Hexadecimal Character...
  • Page 19: Display Dots

    2.51. DISPLAY DOTS Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4, *5, *6, *7, *8) Hexadecimal Character Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY VIDEO S-VIDEO Note: • The maximum value that can be actually set changes according to the input signal or the input resolution settings, etc. •...
  • Page 20: Display Lines

    2.53. DISPLAY LINES Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4, *5, *6, *7, *8) Hexadecimal Character Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY VIDEO S-VIDEO Note: • The maximum value that can be actually set changes according to the input signal or the input resolution settings, etc. •...
  • Page 21 2.56. LINEARITY Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY Note: • Calls back ER401 when 0 is set to KEYSTONE. 2.57.
  • Page 22 2.59. BLANKING UPPER Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character Hexadecimal Character Note: • The maximum value that can be set changes according to settings of the input signal, the aspect and the zoom. Response (Callback) In the period when the command can be accepted Hexadecimal...
  • Page 23 2.61. BLANKING RIGHT Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character PT-D5700*/D5700L* Hexadecimal Character PT-DW5100*/DW5100L* Hexadecimal Character Note: • The maximum value that can be set changes according to settings of the input signal, the aspect and the zoom. Response (Callback) In the period when the command can be accepted Hexadecimal...
  • Page 24: Raster Position

    2.63. RASTER POSITION H Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4, *5, *6, *7, *8) Hexadecimal Character Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY Note: • The maximum value that can be set changes according to settings of the input signal, the aspect and the zoom. 2.64.
  • Page 25: Xga Mode

    2.66. Color Matching Hexadecimal Character Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4, *5, *6, *7, *8, *9, *10) Hexadecimal Character Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Hexadecimal Character Acceptability SECURITY STNDBY 2.67.
  • Page 26: Sxga Mode

    2.69. SXGA MODE Hexadecimal Character Hexadecimal Character Parameters (*1, *2) SXGA Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY 2.70. CONTRAST MODE Hexadecimal Character Hexadecimal Character Parameters (*1, *2, *3, *4, *5, *6) NORMAL Hexadecimal Character...
  • Page 27 2.73. Set Date Hexadecimal Character Hexadecimal Character Parameters *y1—*y4: Year (4 digits) *m1, *m2 Month (2 digits) *d1, *d2: Day (2 digits) *w: Day of the week (Mon = 1, Tue = 2, Wed = 3, Thu = 4, Fri = 5, Sat = 6, Sun = 7) Set it by UTC (Coordinated Universal Time).
  • Page 28 2.76. Query FREEZE Hexadecimal Character Response (Callback) Hexadecimal Character Hexadecimal Character Acceptability SECURITY STNDBY 2.77. Query SHUTTER Hexadecimal Character Response (Callback) Hexadecimal Character Hexadecimal Character Acceptability SECURITY STNDBY 2.78. Query Input Select Hexadecimal Character Response (Callback) RGB1 Hexadecimal Character RGB2 Hexadecimal Character VIDEO...
  • Page 29 2.80. Query ON SCREEN Hexadecimal Character Response (Callback) OSD OFF Hexadecimal Character OSD ON Hexadecimal Character Acceptability SECURITY STNDBY 2.81. Query PICTURE MODE Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY Parameters (*1, *2, *3, *4, *5, *6) DYNAMIC...
  • Page 30 2.84. Query COLOR TEMP. Hexadecimal Character Response (Callback) DEFAULT Hexadecimal Character USER Hexadecimal Character MIDDLE Hexadecimal Character HIGH Hexadecimal Character Acceptability SECURITY STNDBY 2.85. Query W-BAL LOW R Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability...
  • Page 31 2.87. Query W-BAL LOW B Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character Hexadecimal Character 2.88. Query W-BAL HIGH R Hexadecimal Character Response (Callback) In the period when the command can be accepted...
  • Page 32 2.91. Query CONTRAST Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character Hexadecimal Character 2.92. Query BRIGHT Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability...
  • Page 33 2.94. Query System Daylight View Hexadecimal Character Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Hexadecimal Character Acceptability SECURITY STNDBY Parameters (*1, *2, *3, *4, *5, *6, *7, *8, *9, *10) Hexadecimal Character Hexadecimal Character 2.95.
  • Page 34 2.98. Query TV-SYSTEM Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character NTSC4.43 Hexadecimal Character Hexadecimal Character 2.99. Query POSITION H Hexadecimal Character Response (Callback) In the period when the command can be accepted...
  • Page 35 2.101. Query RASTER POSITION H Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY Parameters (*1, *2, *3, *4, *5, *6, *7, *8) Hexadecimal Character Hexadecimal Character 2.102. Query RASTER POSITION V Hexadecimal Character Response (Callback)
  • Page 36: Video S-Video

    2.105. Query ZOOM V Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character Hexadecimal Character 2.106. Query CLOCK PHASE Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character...
  • Page 37 2.108. Query DISPLAY DOTS / INPUT RESOLUTION Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY VIDEO S-VIDEO Parameters (*1, *2, *3, *4, *5, *6, *7, *8) Hexadecimal Character Hexadecimal Character 2.109.
  • Page 38 2.111. Query BLANKING UPPER Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character Hexadecimal Character 2.112. Query BLANKING LOWER Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character...
  • Page 39 2.114. Query BLANKING LEFT Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character PT-D5700*/D5700L* Hexadecimal Character PT-DW5100*/DW5100L* Hexadecimal Character 2.115. Query Edge Blending Hexadecimal Character Hexadecimal...
  • Page 40 2.117. Query Color Correction Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY Parameters (*1, *2) Hexadecimal Character 2.118. Query XGA MODE Hexadecimal Character Parameters (*1, *2) Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character...
  • Page 41 2.121. Query CLAMP POS. Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY VIDEO S-VIDEO Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character Hexadecimal Character 2.122. Query KEYSTONE Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal...
  • Page 42 2.124. Query LANGUAGE Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY Parameters (*1, *2, *3, *4, *5, *6) Hexadecimal Character Spanish Hexadecimal Character Chinese Hexadecimal Character 2.125. Query Installation (FRONT/REAR & DESK/CEILING) Hexadecimal Character Response (Callback)
  • Page 43 2.127. Query LAMP1 ON Hexadecimal Character Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY Parameters (*1, *2, *3, *4, *5, *6, *7, *8) When the lamp is Normal type Answered time = (Lamp ON time in HIGH) + ((Lamp ON time in LOW) No. 3 ÷ 4) When the lamp is Long-life type Answered time = Lamp ON time Hexadecimal...
  • Page 44 2.130. Query Lamp Status Hexadecimal Character Response (Callback) Lamp OFF Hexadecimal Character In turning ON Hexadecimal Character Lamp ON Hexadecimal Character In turning OFF (Cooling) Hexadecimal Character Acceptability SECURITY STNDBY 2.131. Query LAMP POWER Hexadecimal Character Response (Callback) When the lamp is Normal type and HIGH setting Hexadecimal Character When the lamp is Normal type and LOW setting...
  • Page 45 2.133. Query Temperature Hexadecimal Character Hexadecimal Character Parameters (*1, *2) Intake air temperature Hexadecimal Character Response (Callback) For 20 °C Hexadecimal Character For 120 °C Hexadecimal Character Acceptability SECURITY STNDBY 2.134. Query FAN CONTROL1 Hexadecimal Character Response (Callback) NORMAL Hexadecimal Character HIGHLAND Hexadecimal...
  • Page 46 2.136. Query Usage Condition of Sub Memory Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Acceptability SECURITY STNDBY Parameters (*1, *2, *3, *4) Calls back ER401 when the sub memory is not used. Hexadecimal Character Hexadecimal...
  • Page 47 2.139. Query Model (Series) Name Hexadecimal Character Response (Callback) In the period when the command can be accepted PT-D5700*/D5700L* Hexadecimal Character PT-DW5100*/DW5100L* Hexadecimal Character Acceptability SECURITY STNDBY 2.140. Query Lamp ON Status Hexadecimal Character Response (Callback) Lamp 1 OFF, Lamp 2 OFF Hexadecimal Character Lamp 1 ON, Lamp 2 OFF...
  • Page 48 2.143. Query DVI Signal Level Hexadecimal Character Hexadecimal Character Response (Callback) In the period when the command can be accepted Hexadecimal Character Hexadecimal Character Acceptability SECURITY STNDBY Parameters (*1, *2, *3, *4, *5, *6, *7, *8, *9, *10) Hexadecimal Character NO SIGNAL SHUTTER FREEZE...
  • Page 49 3. Extended Control Command Start (STX) 1 byte 1 byte ID of the extended control command Hexadecimal (1 byte) ID23 ID24 ID25 ID26 ID27 ID28 ID29 ID30 ID31 ID32 ID10 ID33 ID11 ID34 ID12 ID35 ID13 ID36 ID14 ID37 ID15 ID38 ID16 ID39...
  • Page 50 It fails in the operation of the shutter. It is a breakdown when not recovering even if the power is turned on again. The thermosensor in this projector has breaking of wire, or connector A10 is disconnected. The intake air thermosensor has breaking of wire, or connector A9 is disconnected.
  • Page 51 Description The ambient temperature in the place of use may be 0°C or lower. If the temperature inside this projector does not rise within 5 minutes after the turning on the lamp, the shutdown occurs. The temperature inside this projector has become high. If the temperature rises any further, the shutdown occurs.

This manual is also suitable for:

Pt-d5700Pt-dw5100Rs-232c

Table of Contents