Menu item
(Continued)

FLARE

Variable
Layer
Item
range
1
RFLAR
–100
:
+100
GFLAR
–100
:
+100
BFLAR
–100
:
+100
2
FLAR-
ON
CORRECT
OFF
<Note>
When the BLACK volume is assigned for flare
adjustment, it must be set in BLACK-VR-CONTROL,
BLACK-VR-MODE, and BLACK-VR-RANGE. When
"FLR" is selected in the BLACK-VR-CONTROL item, the
flare can be adjusted by using the BLACK volume.
Switching between the absolute value mode and the
relative value mode of the volume can be set in the
BLACK-VR-MODE item, while switching of the variable
range can be set in the BLACK-VR-RANGE item. When
the absolute value is selected in the BLACK-VR-MODE
item or the lamp of the VR-ACTIVE button is turned on,
R FLAR/G FLAR/B FLAR items cannot be adjusted
using the rotary encoder. They must be adjusted with
the BLACK volume.

GAMMA

Variable
Layer
Item
range
1
RGAM
–15
:
+15
MGAM
0.30
:
0.75
BGAM
–15
:
+15
2
GAMMA-
HD
MODE-SEL
SD
F-LIKE1
F-LIKE2
F-LIKE3
3
GAMMA-
ON
CORRECT
OFF
E-25
Contents description Storage
To set the flare for Rch
To set the flare for Gch
To set the flare for Bch
To set ON/OFF of the
flare correction
Contents description Storage
To set the gamma for
Rch
To set the master
gamma
To set the gamma for
Bch
To select the gamma
To set ON/OFF of the
gamma correction

WHITE

Layer
Item
1
RGAIN
Yes
BGAIN
Yes
2
FILTER-INH ON
Yes
Yes
3
SKLS-AWB OFF
AWBAREA 25%
4
GAIN-VR-
MODE
Yes
5
GAIN-VR-
Yes
RANGE
Yes
<Note>
When the absolute value is selected in the GAIN-VR-
MODE item, or the lamp of the VR ACTIVE button is
Yes
turned on, the R GAIN/G GAIN items cannot be
adjusted using the rotary encoder. They must be
adjusted using the GAIN volume.
Yes
is the factory setting mode.
Variable
Contents description Storage
range
–200
To set the Rch gain
:
+200
–200
To set the Bch gain
:
+200
To select whether the
OFF
filter has data for the
AWB memory (Ach,
Bch) or not, for the
respective filters
independently
ON:
Data are held in
two memory
locations (Ach,
Bch) regardless
of the filter.
OFF: The respective
filters hold data.
To turn on the shock-
FAST
less AWB (FAST/
NORMAL
NORMAL/SLOW1/
SLOW1
SLOW2/SLOW3)
SLOW2
SLOW3
To switch the AWB
50%
detection area
90%
ABS
To select whether the
REL
GAIN volumes for R
and B are operated
using the absolute
value or the relative
value
ABS: Absolute value
REL: Relative value
MIN
To switch the variable
NORM
range of the GAIN
MAX
volumes for R and B
n50
MIN:
NORM: n100
n200
MAX:
Yes
Yes
Yes
Yes
Yes
Yes
Yes