Siemens SIMATIC NET RUGGEDCOM RST916C Installation Manual
Siemens SIMATIC NET RUGGEDCOM RST916C Installation Manual

Siemens SIMATIC NET RUGGEDCOM RST916C Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RST916C:

Advertisement

Quick Links

Edition
04/2023
Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RST916C
https://www.siemens.com/ruggedcom

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM RST916C

  • Page 1 Edition 04/2023 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RST916C https://www.siemens.com/ruggedcom...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RST916C Communication Ports Technical Specifications Installation Manual Certification 04/2023 C79000-G8976-1490-07...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing documentation ......................v Registered trademarks ......................v Warranty ..........................vi Training ..........................vi Customer support ........................vii Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................2 Description ......................2 Required Tools and Materials ................. 4 Decommissioning and disposal ................4 Installing the Device ......................
  • Page 5 Table of contents Copper Ethernet Port Specifications ..............30 Operating Environment ..................31 Mechanical Specifications ..................31 Dimension Drawings ................... 31 Certification ......................... 35 Approvals ......................35 6.1.1 UKCA ........................35 6.1.2 CSA ........................35 6.1.3 European Union (EU) ..................36 6.1.4 FCC ........................
  • Page 6: Preface

    SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Accessing documentation The latest user documentation for RUGGEDCOM RST916C is available online at https://support.industry.siemens.com.
  • Page 7: Warranty

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 8: Customer Support

    Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile app Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RST916C Installation Manual, 04/2023, C79000-G8976-1490-07...
  • Page 10: Introduction

    Introduction The RUGGEDCOM RST916C is a 16-port utility-grade, fully managed Ethernet switch specifically designed to operate reliably in electrically harsh and climatically demanding environments. • Removable SFP Transceivers The device supports up to four Small Form-factor Portable (SFP) transceivers, allowing the device to be adapted to the requirements of the network application.
  • Page 11: Feature Highlights

    Introduction 1.1 Feature Highlights • RUGGEDCOM ROS RUGGEDCOM ROS provides advanced Layer 2 networking functions and cyber security features. Feature Highlights Ethernet Ports • 4 x sockets for SFP/SFP+ transceivers • 12 x 10/100/1000Base-T copper Ethernet ports Rated for Reliability in Harsh Environments •...
  • Page 12 Introduction 1.2 Description LO DC Variant HI AC/DC Variant POWER LED ALARM LED USB Console Port CLP Port SFP Tranceiver Sockets (Ports 11 to 14) Copper Ethernet Ports (Ports 1 to 10, 15, and 16) Failsafe Alarm Relay Power Supply Terminal Block Chassis Ground Screw Figure 1.1 RUGGEDCOM RST916C...
  • Page 13: Required Tools And Materials

    WEEE directive 2012/19/EU for the disposal of electrical and electronic equipment. Do not dispose of devices at public disposal sites. For environmentally friendly recycling and the disposal of devices, contact a certified disposal company for electronic scrap or your Siemens contact. RUGGEDCOM RST916C Installation Manual, 04/2023, C79000-G8976-1490-07...
  • Page 14 Introduction 1.4 Decommissioning and disposal For more information, refer to https://support.industry.siemens.com/cs/ww/en/ view/109479891. Note the different national regulations. RUGGEDCOM RST916C Installation Manual, 04/2023, C79000-G8976-1490-07...
  • Page 15 Introduction 1.4 Decommissioning and disposal RUGGEDCOM RST916C Installation Manual, 04/2023, C79000-G8976-1490-07...
  • Page 16: Installing The Device

    Installing the Device This chapter describes how to install the device, including mounting the device, connecting power, and connecting the device to the network. DANGER Electrocution hazard – risk of serious personal injury and/or damage to equipment Before performing any maintenance tasks, make sure all power to the device has been disconnected and wait approximately two minutes for any remaining energy to dissipate.
  • Page 17: General Procedure

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 18: Unpacking The Device

    Visually inspect each item in the package for any physical damage. Verify all items are included. Note If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RST916C is designed for maximum mounting and display flexibility.
  • Page 19 Installing the Device 2.3.1 Mounting the Device on a DIN Rail DIN Rail DIN Rail Adapter Figure 2.1 Mounting the Device to a DIN Rail Insert a flathead screwdriver into the slot of the sliding release and move it down. Push the device against the bottom of the DIN rail, then let go of the sliding release to latch the device.
  • Page 20: 2.3.2 Mounting The Device To A Panel

    Installing the Device 2.3.2 Mounting the Device to a Panel DIN Rail DIN Rail Adapter Figure 2.2 Removing the Device from a DIN Rail Swing the bottom of the device away from the DIN rail. Lift the device off the DIN rail. 2.3.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RST916C can be equipped with panel...
  • Page 21 Installing the Device 2.3.2 Mounting the Device to a Panel Side-Mount Orientation Figure 2.3 Panel Mount Options To mount the device to a panel, do the following: Secure the mounting adapters to the top and bottom of the device in the desired orientation using the eight M4 screws included with the device.
  • Page 22: Connecting The Failsafe Alarm Relay

    Installing the Device 2.4 Connecting the Failsafe Alarm Relay Screw (M5 or #10-24) Panel Mount Adapter Figure 2.5 Panel Mounting (Rear Mount Orientation) Secure the adapters to the panel with screws. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions. The NO (Normally Open) contact is closed when the unit is powered and there are no active alarms.
  • Page 23 Installing the Device 2.4 Connecting the Failsafe Alarm Relay Figure 2.6 Assembling the Failsafe Alarm Relay Terminal Block Connect a failsafe device to the terminal block. Failsafe Alarm Relay Terminal Block Normally Open Common Normally Closed Figure 2.7 Failsafe Alarm Relay Wiring RUGGEDCOM RST916C Installation Manual, 04/2023, C79000-G8976-1490-07...
  • Page 24: Connecting Power

    Installing the Device 2.5 Connecting Power Connecting Power The RUGGEDCOM RST916C features two input terminals that allow the device to be powered by: • Up to one independent AC and one independent DC power source • Two independent DC power sources Note The RUGGEDCOM RST916C is a dual input power supply system.
  • Page 25 Installing the Device 2.5.1 Connecting AC or DC Power Each variant of the RUGGEDCOM RST916C features dual power supply inputs to allow for redundant connections to separate, independent external power supplies. Depending on the device variant, the following are supported: • One AC power source and one DC power source •...
  • Page 26 Installing the Device 2.5.1 Connecting AC or DC Power Figure 2.8 Assembling the Power Terminal Blocks Note Torque all terminal connections to 0.6 N·m (5 lbf-in). Connect the power cable to the device as follows: HI AC/DC Power Supply   Connect the Line wire (AC) or Positive wire (DC) to the positive/ live (+/L) terminal on the terminal block.
  • Page 27: 2.5.2 Wiring Examples

    Installing the Device 2.5.2 Wiring Examples Connect the chassis ground screw to ground (Potential Earth). It is recommended to terminate the ground connection with an M4 ring or spade lug, and then torque to 1.7 N·m (15 lbf-in). M4 Screw M4 Ring Lug Figure 2.11 Chassis Ground Connection Connect the external power supply to a power source.
  • Page 28 Installing the Device 2.5.2 Wiring Examples   Figure 2.14 Dual HI AC and DC Power Figure 2.15 Dual HI DC Power Supplies Supplies LO Power Supply Configurations   Figure 2.16 Single LO DC Power Input Figure 2.17 Dual LO DC Power Input Configuration Configuration RUGGEDCOM RST916C Installation Manual, 04/2023, C79000-G8976-1490-07...
  • Page 29 Installing the Device 2.5.2 Wiring Examples RUGGEDCOM RST916C Installation Manual, 04/2023, C79000-G8976-1490-07...
  • Page 30: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RST916C console and Web interfaces on the device. For more detailed instructions, refer to the "RUGGEDCOM ROS Configuration Manual" for the RUGGEDCOM RST916C. Console Port Connect a workstation directly to the USB Type-B console port to access the boot- time control and RUGGEDCOM RST916C interfaces.
  • Page 31: Configuring The Device

    Device Management 3.2 Configuring the Device device's IP address. The factory default IP address for the RUGGEDCOM RST916C is https://192.168.0.1. For more information about available ports, refer to "Communication Ports" (Page 25). Configuring the Device Once the device is installed and connected to the network, it must be configured. All configuration management is done via the RUGGEDCOM RST916C interface.
  • Page 32 Device Management 3.3 Inserting/Removing the CLP Removing the CLP To remove the CLP, do the following: NOTICE Configuration hazard – risk of data loss After uploading or downloading a file, allow at least twenty seconds before removing the CLP to ensure the data has been fully transferred. Remove the CLP (or blank insert) from the CLP port.
  • Page 33 Device Management 3.3 Inserting/Removing the CLP Blank Insert Figure 3.2 Inserting the CLP Insert the CLP into the CLP port. RUGGEDCOM RST916C Installation Manual, 04/2023, C79000-G8976-1490-07...
  • Page 34: Communication Ports

    Communication Ports The RUGGEDCOM RST916C can be equipped with various types of communication ports to enhance its abilities and performance. Ports 1 to 10 Ports 11 to 14 Ports 15 to 16 Figure 4.1 Port Assignment Port Type 1 to 10 Copper (10/100/1000Base-T) Ethernet Ports 11 to 14 SFP/SFP+ Transceivers...
  • Page 35: Copper Ethernet Ports

    Communication Ports 4.1 Copper Ethernet Ports Copper Ethernet Ports The device supports multiple 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5E (CAT-5E) or higher shielded twisted-pair cables with RJ45 male connectors. WARNING Electric shock hazard – risk of serious personal injury and/or equipment interference When shielded cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end.
  • Page 36: Sfp Transceivers

    "RUGGEDCOM SFP Transceiver Catalog [https:// support.industry.siemens.com/cs/ca/en/view/109482309]". Note Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components. RUGGEDCOM RST916C...
  • Page 37 Communication Ports 4.2 SFP Transceivers RUGGEDCOM RST916C Installation Manual, 04/2023, C79000-G8976-1490-07...
  • Page 38: Technical Specifications

    Technical Specifications This section provides important technical specifications related to the device. Power Supply Specifications Note When determining cable lengths, make sure the nominal input voltage for the power supply is provided at the power source. Power Input Voltage Internal Isolation Maximum Supply Type...
  • Page 39: Supported Networking Standards

    Technical Specifications 5.3 Supported Networking Standards Supported Networking Standards The following networking standards are supported by RUGGEDCOM RST916C: Standard 10 Mbps 1000 10000 Description Mbps Mbps Mbps IEEE 802.1AB Link Layer Discovery Ÿ Ÿ Ÿ Ÿ Protocol (LLDP) IEEE 802.1D MAC bridges, Spanning Ÿ...
  • Page 40: Operating Environment

    Technical Specifications 5.5 Operating Environment RMS 1 minute. Operating Environment The RUGGEDCOM RST916C is rated to operate under the following environmental conditions. Ambient Operating -40 to 85 °C (-40 to 185 °F) Temperature (Non-Hazardous Environments) Ambient Operating -40 to 80 °C (-40 to 176 °F) Temperature (Hazardous Environments) Ambient Storage Temperature...
  • Page 41 Technical Specifications 5.7 Dimension Drawings 116.1 164.5 Figure 5.1 Overall Dimensions 116.1 78.6 60.0 165.3 Figure 5.2 Panel Mount Dimensions (Rear Mount Orientation) RUGGEDCOM RST916C Installation Manual, 04/2023, C79000-G8976-1490-07...
  • Page 42 Technical Specifications 5.7 Dimension Drawings 125.1 107.9 55.0 69.3 16.3 60.0 132.5 Figure 5.3 Panel Mount Dimensions (Side Mount Orientation) RUGGEDCOM RST916C Installation Manual, 04/2023, C79000-G8976-1490-07...
  • Page 43 Technical Specifications 5.7 Dimension Drawings RUGGEDCOM RST916C Installation Manual, 04/2023, C79000-G8976-1490-07...
  • Page 44: Certification

    Approvals This section details the standards to which the RUGGEDCOM RST916C complies. Note All relevant certificates and test reports are available on Siemens Industry Online Support [https://support.industry.siemens.com/cs/ww/en/ps/16008/cert]. 6.1.1 UKCA This device is certified for use in Great Britain and bears the United Kingdom Certified Assessed (UKCA) marking.
  • Page 45: European Union (Eu)

    Certification 6.1.3 European Union (EU) 6.1.3 European Union (EU) This device is declared by Siemens Canada Ltd. to comply with essential requirements and other relevant provisions of the following EU directives: • EN 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements •...
  • Page 46: Fda/Cdrh

    Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.6 ISED This device is declared by Siemens Canada Ltd. to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.7...
  • Page 47: 6.1.9 Iso

    Quality management systems – Requirements 6.1.10 RoHS This device is declared by Siemens Canada Ltd. to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: EU RoHS Directives (EU) 2011/65 and (EU) 2015/863 •...
  • Page 48: Emc And Environmental Type Tests

    Certification 6.2 EMC and Environmental Type Tests • EN 50121-4 Railway applications – Electromagnetic Compatibility – Emission and Immunity of the Signaling and Telecommunications Apparatus EN 50121-3-2 • Railway applications – Electromagnetic Compatibility – Rolling Stock Apparatus • EN 50155 Railway applications – Rolling stock – Electronic equipment •...
  • Page 49 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels Magnetic Field Enclosure 100 A/m Continuous   61000-4-8 Ports 1000 A/m for 1 s Pulse Magnetic Field Enclosure 300 A/m 61000-4-9 Ports Voltage Dips and Interrupts AC Power 30% for 0.5 Cycles  ...
  • Page 50 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels AC Power Ports ± 4 kV @ 2.5 kHz, 5 kHz Earth Ground Ports ± 4 kV IEEE 1613 Oscillatory Signal Ports 2.5 kV Common Mode @ 1 MHz DC Power Ports 2.5 kV Common Mode @ 1 MHz 1 kV Differential...
  • Page 51 Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM RST916C Installation Manual, 04/2023, C79000-G8976-1490-07...
  • Page 52 For more information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens Canada Ltd. Digital Industries Process Automation 300 Applewood Crescent Concord, Ontario, L4K 4E5 Canada © 2023 Siemens Canada Ltd. Subject to change...

Table of Contents