Error Codes Operational Check - Mitsubishi Electric LT-40148 Service Manual

Lcd flat panel television
Hide thumbs Also See for LT-40148:
Table of Contents

Advertisement

MODELS: LT-40148 / LT-46148 / LT-46149 / LT-46246 / LT-52148 / LT 52149 / LT-52246
Error Code Operational Check
Note: The TV must be in "Shut Down" and not have been switched Off, to perform the Error Code Opera-
tional Check. When the TV is switched Off, the code automatically resets to "12" No Error.
Pressing the front panel "INPUT" and "MENU" buttons at the same time, and holding for 5 seconds,
activates the Error Code Mode. The "POWER LED" flashes denoting a two digit Error Code, or indicating no
problem has occurred since the last Initialization.
Note: The front panel buttons must be used, NOT those on the Remote Control.
The number of flashes indicates the value of the MSD (tens digit) of the Error Code.
The flashing then pauses for approximately 1/2 second.
The LED then flashes indicating the value of the LSD (ones digit) of the Error Code.
The Error Code is repeated a total of 5 times.
(EXAMPLE) - When the error code is 35, the LED flashes as follows
ERROR CODES
Error Code
12
Normal off
27
Inverter short detected
28
FPGA download failure
29
FRC communication error
41
3.3VS or 5VS STANDBY-SHORT
44
LVDS Cable connection detection
48
3.3V PON-SHORT
59
Panel 12V Short
Error Code Log
The Error Code Log - may be helpful to retrieve the code for an error that occurred in the past.
To access the Error Code Log: Press <MENU> <3-5-6-4>
Error Code Definitions
• Page - Current page number
• Current Time - total hours of operational use.
• Lamp Time - usage hours when the error
occurred.
• Code - the specific Error Code that occurred.
• Two types:
OCCURRENCE - when the error occurred.
RECOVERY - when normal operation resumed.
NOTE: The Error Code Log is intended as a reference tool and is not meant to be used as a final determination of a
defective part.
Ca use
No Problem detected
PW B-POW ER - No 24 V at PC-Pins 1~5
PW B-MAIN
PW B-MAIN
PW B-MAIN
Loose LVDS Cable at PW B-MAIN (VR) or Panel Assembly
PW B-MAIN
PW B-POW ER - No 12 V at PB-Pins 9 & 10
***** PAGE (002/002) *****
CURRENT TIME: 01455 HOURS
LAMP T IME
00413 HRS
00413 HRS
00716 HRS
00716 HRS
00905 HRS
00905 HRS
Page 25
Most Like ly Fa ilure
CODE STATUS
57
OCCURRENCE
57
RECO VERY
Press Up to Previous Pa ge
32
OCCURRENCE
32
RECO VERY
Press Right to Top Page
61
OCCURRENCE
61
RECO VERY
Press CANCEL to Initialize
Press MENU to Exit