KEEP THIS MANUAL FOR FUTURE REFERENCE
BEDIENUNGSANLEITUNG
BEWAHREN SIE DIESES HANDBUCH ZUM SPÄTEREN NACHSCHLAGEN AUF
MODE D'EMPLOI
CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE
MANUAL DE FUNCIONAMIENTO
CONSERVE ESTE MANUAL PARA SU FUTURA CONSULTA
MANUALE DI ISTRUZIONI
CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI
ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
ΦΥΛΑΞΤΕ ΤΟ ΕΓΧΕΙΡΙΔΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ
MANUAL DE INSTRUÇÕES
GUARDE ESTE MANUAL PARA REFERÊNCIA FUTURA
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
РУКОВОДСТВО ДЛЯ СПРАВОК В БУДУЩЕМ
KULLANMA KİTABI
BU KILAVUZU, DAHA SONRA BAŞVURMAK ÜZERE SAKLAYIN
PART No. 9378787025

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu UTY-LRHYA2

  • Page 1 OPTIONAL PARTS RECEIVER KIT (for CASSETTE TYPE INDOOR UNIT) OPERATING MANUAL KEEP THIS MANUAL FOR FUTURE REFERENCE BEDIENUNGSANLEITUNG BEWAHREN SIE DIESES HANDBUCH ZUM SPÄTEREN NACHSCHLAGEN AUF MODE D’EMPLOI CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE MANUAL DE FUNCIONAMIENTO CONSERVE ESTE MANUAL PARA SU FUTURA CONSULTA MANUALE DI ISTRUZIONI CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI ΕΓΧΕΙΡΙΔΙΟ...
  • Page 2: Table Of Contents

    RECEIVER KIT (for CASSETTE TYPE INDOOR UNIT) CONTENTS PART No. 9378787025 SAFETY PRECAUTIONS ........2 ADJUSTING THE DIRECTION OF AIR CIRCULATION ..11 FEATURES AND FUNCTIONS ....... 3 SWING OPERATION ..........11 NAME OF PARTS ........... 4 ECONOMY OPERATION ........12 PREPARATION ............6 10°C HEAT OPERATION ........
  • Page 3: Features And Functions

    SAFETY PRECAUTIONS Do not use infl ammable gases near the air conditioner. ● CAUTION This appliance is not intended for use by persons (including children) with reduced ● physical, sensory or mental capabilities, or lack of experience and knowledge, un- less they have been given supervision or instruction concerning use of the appli- ance by a person responsible for their safety.
  • Page 4: Name Of Parts

    NAME OF PARTS Indoor unit Control panel 1 Remote control signal receiver 2 MANUAL AUTO button When the MANUAL AUTO button is pressed in for more than ● 10 seconds, the forced cooling operation will start. The forced cooling operation is used at the time of installa- ●...
  • Page 5 NAME OF PARTS Remote controller Display panel Display panel To facilitate explanation, the accompanying illustration has been drawn to show all possible indicators; in actual oper- ation, however, the display will only show those indicators appropriate to the current operation. 1 MODE button E Signal transmitter 2 10°C HEAT button...
  • Page 6: Preparation

    PREPARATION CAUTION Load Batteries (R03/LR03 × 2) ● Take care to prevent infants from acciden- tally swallowing batteries. Press and slide the battery compartment lid on the ● When not using the remote controller for an reverse side to open it. extended period, remove the batteries to avoid possible leakage and damage to the Slide in the direction of the arrow while pressing the...
  • Page 7: Operation

    OPERATION To Select Mode Operation Press the START/STOP button. The indoor unit’s OPERATION indicator lamp will light. The air conditioner will start operating. Press the MODE button to select the desired mode. Each time the button is pressed, the mode will change in the following order. AUTO COOL HEAT...
  • Page 8 OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). To Stop Operation Press the START/STOP button. The OPERATION indicator lamp will go out. MODE Operation AUTO (in COOLING model): When AUTO (automatic changeover) operation fi rst selected, the fan will ●...
  • Page 9: Timer Operation

    TIMER OPERATION Before using the timer function, be sure that the remote controller is set to the correct current time (☞ Page 6.) If the indoor unit is connected to a wired remote controller, the wireless remote controller cannot be used to set the timer. Note: In simultaneous multi connection, this function by using the wireless remote controller cannot be used.
  • Page 10: Sleep Timer Operation

    SLEEP TIMER OPERATION Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped. If the indoor unit is connected to a wired remote controller, the wireless remote controller cannot be used to set the sleep timer. Note: In simultaneous multi connection, this function by using the wireless remote controller cannot be used.
  • Page 11: Adjusting The Direction Of Air Circulation

    ADJUSTING THE DIRECTION OF AIR CIRCULATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Begin air conditioner operation before performing this procedure. Vertical Air Direction Adjustment Press the SET button (Vertical). Each time the button is pressed, the air direction range will change as follows: The remote controller’s display ●...
  • Page 12: Economy Operation

    ECONOMY OPERATION Begin air conditioner operation before performing this procedure. To Use the ECONOMY Operation Indicator Lamp Press the ECONOMY button. The ECONOMY indicator lamp (green) will light. ECONOMY operation begins. To Stop the ECONOMY Operation :Lighting :OFF Press the ECONOMY button again. The ECONOMY indicator lamp (green) will go out.
  • Page 13: Selecting The Remote Controller Signal Code

    SELECTING THE REMOTE CONTROLLER SIGNAL CODE When two or more air conditioners are installed in a room and the Remote Controller is operating an air conditioner other than the one you wish to set, change the signal code of the Remote Controller to operate only the air conditioner you wish to set (4 selections possible).
  • Page 14: Cleaning And Care

    CLEANING AND CARE ● Before cleaning the unit, be sure to stop the unit and disconnect the power supply. CAUTION ● Turn off the electrical breaker. ● A fan operates at high speed inside the unit, and personal injury could result. ●...
  • Page 15: Troubleshooting

    CLEANING AND CARE Filter Reset (ECONOMY indicator lamp fl ashing/ A special setting) Can be used if set correctly during installation. ● Please consult authorized service personnel when using this function. • It lights on when it is time to clean the air fi lters. After turning the power on, press the MANUAL AUTO button for 2 seconds or less on the indoor unit.
  • Page 16 TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Symptom Problem See Page NORMAL Water is produced During heating operation, water may be produced from the outdoor unit due ● FUNCTION from the outdoor unit: to the automatic defrosting operation.
  • Page 17: Operating Tips

    OPERATING TIPS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Heating Performance* Microcomputer-controlled Automatic Defrosting* This air conditioner operates on the heat-pump principle, ● When using the heating mode under conditions of low out- ●...
  • Page 18 OPERATING TIPS Multi-type Air Conditioner This indoor unit can be connected to a multi-type outdoor unit. The multi-type air conditioner allows multiple indoor units to be oper- ated in multiple locations. The indoor units may be operated simultaneously, in accordance with their respective output. Simultaneous Use of Multiple Units ❖...