Bosch Condens 8300i W Installation And Maintenance Instructions Manual page 21

Wall mounted gas condensing boiler
Table of Contents

Advertisement

▶ For splash water protection (IP): cut the strain relief to match the
diameter of the cable.
Fig. 26 Adapting the strain relief to the cable diameter
▶ Guide the cable through the strain relief.
▶ Connect the cable to the terminal strip for external accessories (
Fig. 27).
▶ Secure the cable on the strain relief.
ON/OFF
230V
230V
230V
IN
IN
L
N
L
N
Fig. 27 Terminal strip for external accessories
Symbol
Function
Mains voltage
ON/OFF
230V
IN
L N
Power supply connection
230V
IN
L
N
Power supply connection
230V
OUT
L
N
Live switch
Frost thermostat connection
Without function
PC0
L
N
Mains power supply for the heating
pump (max. 100 W) downstream the
PW2
L
N
low loss header in the heating circuit
without mixer
Without function
PW1
L
N
Condens 8300i W – 6721841531 (2022/10)
Ø
5-7
Ø 8-9
Ø 10-12
Ø
13-14
0010019570-001
OUT
PC0
L
N
LR
LR
FS
FR
L
N
Description
On/Off-switch
External power supply
External modules (switched via On/Off switch)
Live return to the device
• k CH output demand
• j DHW output demand (active only when the optional permanently installed diverter
valve is connected)
No setting required in the service menu
▶ Set hydraulic configuration heating circuit 1 with service function 2-A3 to 2.
PW2
PW1
TW1
T0
L
N
L
N
2
1
2
1
T1
LF0
I3
I1
2
1
2
1
2
1
2
1
2
Installation
BUS
1
0010041051-002
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gc8300iw 35cGc8300iw 40c

Table of Contents